| Specifications | 730016 | 730018 | 730017 | 730019 |
| Analog Output | 0 to 1 V for 100% nominal range, load resistance at least 2 k? | 0 to 1 V for 100% nominal range, load resistance at least 2 k? | 0 to 1 V for 100% nominal range, load resistance at least 2 k? | 0 to 1 V for 100% nominal range, load resistance at least 2 k? |
| Certifications | CE | CE | CE | CE |
| Depth English | 7.1 in | 7.1 in | 7.1 in | 7.1 in |
| Depth Metric | 180 mm | 180 mm | 180 mm | 180 mm |
| Height English | 3.9 in | 3.9 in | 3.9 in | 3.9 in |
| Height Metric | 100 mm | 100 mm | 100 mm | 100 mm |
| Hysteresis | 0.1% FS | 0.1% FS | 0.1% FS | 0.1% FS |
| Linearity | ±0.5% FS ±1 digit for mercury models, ±1% FS ±1 digit for water models | ±0.5% FS ±1 digit for mercury models, ±1% FS ±1 digit for water models | ±0.5% FS ±1 digit for mercury models, ±1% FS ±1 digit for water models | ±0.5% FS ±1 digit for mercury models, ±1% FS ±1 digit for water models |
| Liquid | Water | Water | Water | Water |
| Model | KAL 84 L | KAL 84 M | KAL 84 L | KAL 84 M |
| Nominal Temperature Range Metric | 10 to 50 °C | 10 to 50 °C | 10 to 50 °C | 10 to 50 °C |
| Operating Temperature Range Metric | 0 to 60 °C | 0 to 60 °C | 0 to 60 °C | 0 to 60 °C |
| Optional Certificate | Linearity test certificate, DKD (German calibration service, see below) | Linearity test certificate, DKD (German calibration service, see below) | Linearity test certificate, DKD (German calibration service, see below) | Linearity test certificate, DKD (German calibration service, see below) |
| Overpressure Limit | 200% FS for mercury models 500% FS for water models | 200% FS for mercury models 500% FS for water models | 200% FS for mercury models 500% FS for water models | 200% FS for mercury models 500% FS for water models |
| Power | 115 VAC, 60 Hz, 9 V rechargeable battery, mains adapter | 115 VAC, 60 Hz, 9 V rechargeable battery, mains adapter | 230 VAC, 50 Hz, 9 V rechargeable battery, mains adapter | 230 VAC, 50 Hz, 9 V rechargeable battery, mains adapter |
| Pressure Connections | 6.5 mm OD for 5 mm ID tubing | 6.5 mm OD for 5 mm ID tubing | 6.5 mm OD for 5 mm ID tubing | 6.5 mm OD for 5 mm ID tubing |
| Range | Measurement and calibration range for appropriate model (see table below) | Measurement and calibration range for appropriate model (see table below) | Measurement and calibration range for appropriate model (see table below) | Measurement and calibration range for appropriate model (see table below) |
| Range 1 | 0 to 19.99 mmHg | 0 to 199.9 mmHg | 0 to 19.99 mmHg | 0 to 199.9 mmHg |
| Range 2 | 0 to 196.0 kPa | 0 to 1960 kPa | 0 to 196.0 kPa | 0 to 1960 kPa |
| Response Time | TE = 20 ms, time constant can be switched to 0.1 sec or 1 sec | TE = 20 ms, time constant can be switched to 0.1 sec or 1 sec | TE = 20 ms, time constant can be switched to 0.1 sec or 1 sec | TE = 20 ms, time constant can be switched to 0.1 sec or 1 sec |
| Used for Calibrations of? | Low-Range Differential Pressure Transducer like DP45-14 at 10 mmH2O as Nominal Value for PTM (Pneumotachometer) | Low-Range Differential Pressure Transducer like DP45-24 or MPX, Type 399 | Low-Range Differential Pressure Transducer like DP45-14 at 10 mmH2O as Nominal Value for PTM (Pneumotachometer) | Low-Range Differential Pressure Transducer like DP45-24 or MPX, Type 399 |
| Weight English | 6.6 lb | 6.6 lb | 6.6 lb | 6.6 lb |
| Weight Metric | 3 kg | 3 kg | 3 kg | 3 kg |
| Width English | 10.2 | 10.2 | 10.2 | 10.2 |
| Width English UOOM | in | in | in | in |
| Width Metric | 260 | 260 | 260 | 260 |
| Width Metric UOOM | mm | mm | mm | mm |