Venous Pressure Transducers

The P75 has a removable Macrolon® dome with a pressure connection and a vent connection at the side, so that it can be filled free of air bubbles. The dome connections have a male Luer taper so that suitable stopcocks can be attached. The transducer has a metal housing. The actual pressure sensor inside is made from ceramic and therefore has excellent resistance to different media. The transducer’s rugged construction can withstand pressure overloads up to 4000 mmHg without damage. It works together with any DC bridge amplifier (e.g., PLUGSYS TAM-A).
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
730020 Blood Pressure Transducer P75 for PLUGSYS Module -- 10 days View Pricing
Login to Shop
730021 Blood Pressure Transducer P75 for Harvard Apparatus Transducer Interface -- 10 days View Pricing
Login to Shop
730022 Blood Pressure Transducer P75 for Grass Amplifiers -- 10 days View Pricing
Login to Shop
730023 Blood Pressure Transducer P75 for Gould 6600 Series -- 10 days View Pricing
Login to Shop
730024 Blood Pressure Transducer P75 for Gould 4600 Series -- 10 days View Pricing
Login to Shop
730025 Replacement Dome for Venous Blood Pressure -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• For low liquid and gas pressure measurement ±75 mmHg
• Increased sensitivity and baseline stability
• Applications include:
— Venous blood pressure
— Esophageal pressure with fluid filled catheter
— Perfusion pressure on isolated lung and liver
— Perfusion pressure on perfused hollow organs like the esophagus
• Robust construction, easy to fill bubble free

The P75 has a removable Macrolon® dome with a pressure connection and a vent connection at the side, so that it can be filled free of air bubbles. The dome connections have a male Luer taper so that suitable stopcocks can be attached. The transducer has a metal housing. The actual pressure sensor inside is made from ceramic and therefore has excellent resistance to different media. The transducer’s rugged construction can withstand pressure overloads up to 4000 mmHg without damage. It works together with any DC bridge amplifier (e.g., PLUGSYS TAM-A).


Specifications Back to Top

Specifications730020730021730022730023730024730025
CertificationsCECECECECE 
Connection Cable Length English4.9 ft4.9 ft4.9 ft4.9 ft4.9 ft*na ft
Connection Cable Length Metric14.5 m14.5 m14.5 m14.5 m14.5 m*na m
Current Loading15 mA max.15 mA max.15 mA max.15 mA max.15 mA max. 
Frequency Range0 to 100 Hz0 to 100 Hz0 to 100 Hz0 to 100 Hz0 to 100 Hz*na Hz
Linearity±0.15 mmHg±0.15 mmHg±0.15 mmHg±0.15 mmHg±0.15 mmHg*na mmHg
Long-Term Drift±0.04 mmHg±0.04 mmHg±0.04 mmHg±0.04 mmHg±0.04 mmHg*na mmHg
Measurement MediaAll gases and liquids which do not attack Macrolon®All gases and liquids which do not attack Macrolon®All gases and liquids which do not attack Macrolon®All gases and liquids which do not attack Macrolon®All gases and liquids which do not attack Macrolon® 
Mounting Rod Length English2.76 in2.76 in2.76 in2.76 in2.76 in*na in
Mounting Rod Length Metric70 mm70 mm70 mm70 mm70 mm*na mm
Mounting Rod OD English0.31 in0.31 in0.31 in0.31 in0.31 in*na in
Mounting Rod OD Metric8 mm8 mm8 mm8 mm8 mm*na mm
Output Resistance300 ?, nominal300 ?, nominal300 ?, nominal300 ?, nominal300 ?, nominal 
Overload Pressure­760 (= vacuum) to 4000 mmHg­760 (= vacuum) to 4000 mmHg­760 (= vacuum) to 4000 mmHg­760 (= vacuum) to 4000 mmHg­760 (= vacuum) to 4000 mmHg*na mmHg
Pressure ConnectionsLuer taper, maleLuer taper, maleLuer taper, maleLuer taper, maleLuer taper, male 
Pressure Range±75 mmHg±75 mmHg±75 mmHg±75 mmHg±75 mmHg*na mmHg
Range Drift±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C) 
Sensitivity1 mV/mmHg, nominal1 mV/mmHg, nominal1 mV/mmHg, nominal1 mV/mmHg, nominal1 mV/mmHg, nominal 
Suitable AmplifiersAny bridge amp providing 5V DC excitation voltageAny bridge amp providing 5V DC excitation voltageAny bridge amp providing 5V DC excitation voltageAny bridge amp providing 5V DC excitation voltageAny bridge amp providing 5V DC excitation voltage 
Supply Voltage5 V (4.5 to 5.5 V) DC only5 V (4.5 to 5.5 V) DC only5 V (4.5 to 5.5 V) DC only5 V (4.5 to 5.5 V) DC only5 V (4.5 to 5.5 V) DC only 
Temperature Range Metric0 to 50 °C0 to 50 °C0 to 50 °C0 to 50 °C0 to 50 °C*na °C
Transducer English Depth1.381.381.381.381.38 
Transducer Height English1.57 in1.57 in1.57 in1.57 in1.57 in*na in
Transducer Height Metric40 mm40 mm40 mm40 mm40 mm*na mm
Transducer Metric Depth3535353535 
Transducer Width English1.57 in1.57 in1.57 in1.57 in1.57 in*na in
Transducer Width Metric40 mm40 mm40 mm40 mm40 mm*na mm
Volume Displacement0.06 mm3 /10 mmHg0.06 mm3 /10 mmHg0.06 mm3 /10 mmHg0.06 mm3 /10 mmHg0.06 mm3 /10 mmHg 
Weight English0.8 lb0.8 lb0.8 lb0.8 lb0.8 lb*na lb
Weight Metric0.35 kg0.35 kg0.35 kg0.35 kg0.35 kg*na kg
Zero Drift±0.04 mmHg/10°C (0° to 50°C)±0.04 mmHg/10°C (0° to 50°C)±0.04 mmHg/10°C (0° to 50°C)±0.04 mmHg/10°C (0° to 50°C)±0.04 mmHg/10°C (0° to 50°C) 

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 21 results for Venous Pressure Transducers   Page 1  2  3 

Score

Document

Description

100% Login to view HS08 pressure transducer.pdf
[46 KB]
Pressure Transducer use in finding blood pressure and heart rate spectral changes
40% Login to view VT13 Air-sac pressures in little penguins.pdf
[142 KB]
Air-sac pressures in little penguins
36% Login to view HS12P2 Effects of GYK!-16638 in rabbits.pdf
[236 KB]
PII: S0014-2999(00)00591-4
31% Login to view VT06 Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation.pdf
[200 KB]
h4Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation010100051p
26% Login to view HS16 In Vivo Pharmacology of the PDE4 Inhibitor Roflumilast.pdf
[325 KB]
Transducer use In Vivo Efficacy in Airway Disease Models of Rofulmilast
19% Login to view PP94 Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production.pdf
[722 KB]
Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production
13% Login to view HS12P2 1.PDF
[236 KB]
Pressure Transducer use in Antiarrhythmic and electrophysiological effects of GYKI-16638
13% Login to view HS16 Transducer.pdf
[319 KB]
Transducer use In Vivo Efficacy in Airway Disease Models of Rofulmilast
12% Login to view HS07EL Oxytocin actions in guinea-pig uterine artery.pdf
[158 KB]
Displacement Transducer use in Characterization of oxycotin actions in guinea-pig isolated uterin artery: The effect of pregnancy
12% Login to view HS01 Opioids and Coronary Vascular Tone.pdf
[138 KB]
Force Transducer influence of opioids on the vascular tone of isolated porcine coronary artery segments
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for Venous Pressure Transducers  

Score

Document

Description

100% Login to view 603002 603003.pdf
[77 KB]
Research Grade Blood Pressure Transducer Manual
90% Login to view 603002 BP Transducer Manual.pdf
[351 KB]
Research Grade Blood Pressure Transducer User's Manual
90% Login to view 724496 BP Transducer Manual.pdf
[331 KB]
Research Grade Blood Pressure Transducer User's Manual
89% Login to view 724488 724489.pdf
[124 KB]
Research Grade Blood Pressure Transducer Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews