Research Grade Pressure Transducers
This physiological blood pressure transducer uses a semi-disposable dome of medical grade Silastic® with an integral silicone rubber diaphragm. Blood only contacts the diaphragm. Domes are supplied sterile and can be re-sterilized and reused without affecting calibration. Replacement domes are available as accessories.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
724496 Research Grade Blood Pressure Transducer, 115 VAC, 60 Hz Yes -- View Pricing
Login to Shop
724497 Research Grade Blood Pressure Transducer, 230 VAC, 50 Hz -- 10 days View Pricing
Login to Shop
724498 Replacement Dome, pkg. of 1 (older units require retrofit) Yes -- View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

This research grade blood pressure transducer is for use with:
• 72-3732 Data Acquisition System for the IBM-PC with Windows and 72-3733 Data Acquisition System for the Macintosh
• Harvard Apparatus TR2 Chart Recorder, see page I70
• Modular Universal Oscillograph, see pages I66 and I67
• Student Oscillograph, see page I68

This physiological blood pressure transducer uses a semi-disposable dome of medical grade Silastic® with an integral silicone rubber diaphragm. Blood only contacts the diaphragm. Domes are supplied sterile and can be re-sterilized and reused without affecting calibration. Replacement domes are available as accessories.
This transducer converts picofarad changes of capacitance into high-level DC voltages using a new electronic circuit (U.S. Patent #4,142,144). This circuit is extremely sensitive and stable, producing a signal suitable for direct connection to recorders, oscillographs and computers.
The transducer amplifier has a 3-digit back lit LCD display that reads directly in mmHg up to 999. Amplifiers can be stacked for multiple use. It is possible on special order to have as many as 4 amplifiers operated by one transformer.
Please note that replacement domes listed on this page are for Harvard Apparatus’ newer model transducer ONLY. The newer model is distinguished by a black threaded ring at the base of the dome. The older models have a white ring at the base of the dome. We are no longer able to offer replacement domes for these older units.


Specifications Back to Top

Specifications724496724497724498
Amplifier English Depth3-3/83-3/8 
Amplifier Height English2 in2 in*na in
Amplifier Height Metric51 mm51 mm*na mm
Amplifier Metric Depth8686 
Amplifier Width English3.75 in3.75 in*na in
Amplifier Width Metric95 mm95 mm*na mm
Carrier Frequency2 MHz2 MHz*na MHz
CertificationsCECE 
Compliance14 µl displacement /100 mmHg, including 305 mm (12 in) of standard 3 mm (1/8 in) ID vinyl tubing14 µl displacement /100 mmHg, including 305 mm (12 in) of standard 3 mm (1/8 in) ID vinyl tubing 
DisplayLCD, 7.6 mm (0.3 in) high numbersLCD, 7.6 mm (0.3 in) high numbers 
Dome Volume300 µl300 µl*na µl
DriftNegligible after 5 min. warm-upNegligible after 5 min. warm-up 
Electrical Isolation> 1 kV> 1 kV*na kV
Handle Length English3 in3 in*na in
Handle Length Metric76.2 mm76.2 mm*na mm
Handle OD English3/8 in3/8 in*na in
Handle OD Metric9.7 mm9.7 mm*na mm
Input Liquid ConnectorsDual transparent female Luer lockDual transparent female Luer lock 
Linearity±1.5% of full scale±1.5% of full scale 
Natural Frequency> 500 Hz, dry> 500 Hz, dry*na Hz, dry
Output Impedance2 k?2 k?*na k?
Output VoltageFactory set at 1.0 V/100 mmHg via BNC connector; calibrated up to 300 mmHgFactory set at 1.0 V/100 mmHg via BNC connector; calibrated up to 300 mmHg 
Overload Pressure3000 mmHg3000 mmHg*na mmHg
Power115 VAC, 60 Hz230 VAC, 50 Hz 
Pressure Range­50 to +300 mmHg­50 to +300 mmHg*na mmHg
Sterilization of TransducerChemical: Alcide, Cidex, etc.Chemical: Alcide, Cidex, etc. 
Transducer English Depth2.252.25 
Transducer Height English1.5 in1.5 in*na in
Transducer Height Metric43 mm43 mm*na mm
Transducer Metric Depth5555 
Transducer Width English1-1/8 in1-1/8 in*na in
Transducer Width Metric30 mm30 mm*na mm
Weight English2 lb2 lb*na lb
Weight Metric908 g908 g*na g
Zero Offset Control­50 to +100 mmHg­50 to +100 mmHg*na mmHg

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 22 results for Research Grade Pressure Transducers   Page 1  2  3 

Score

Document

Description

100% Login to view HS08 pressure transducer.pdf
[46 KB]
Pressure Transducer use in finding blood pressure and heart rate spectral changes
40% Login to view VT13 Air-sac pressures in little penguins.pdf
[142 KB]
Air-sac pressures in little penguins
36% Login to view HS12P2 Effects of GYK!-16638 in rabbits.pdf
[236 KB]
PII: S0014-2999(00)00591-4
31% Login to view VT06 Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation.pdf
[200 KB]
h4Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation010100051p
26% Login to view HS16 In Vivo Pharmacology of the PDE4 Inhibitor Roflumilast.pdf
[325 KB]
Transducer use In Vivo Efficacy in Airway Disease Models of Rofulmilast
19% Login to view PP94 Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production.pdf
[722 KB]
Aquaporin Deletion in Mice Reduces Intraocular Pressure and Aqueous Fluid Production
13% Login to view HS12P2 1.PDF
[236 KB]
Pressure Transducer use in Antiarrhythmic and electrophysiological effects of GYKI-16638
13% Login to view HS16 Transducer.pdf
[319 KB]
Transducer use In Vivo Efficacy in Airway Disease Models of Rofulmilast
12% Login to view HS07EL Oxytocin actions in guinea-pig uterine artery.pdf
[158 KB]
Displacement Transducer use in Characterization of oxycotin actions in guinea-pig isolated uterin artery: The effect of pregnancy
12% Login to view HS01 Opioids and Coronary Vascular Tone.pdf
[138 KB]
Force Transducer influence of opioids on the vascular tone of isolated porcine coronary artery segments
   

Back to Top



Manuals Back to Top

Displaying 1 to 3 of 3 results for Research Grade Pressure Transducers  

Score

Document

Description

100% Login to view 724496 BP Transducer Manual.pdf
[331 KB]
Research Grade Blood Pressure Transducer User's Manual
88% Login to view 603002 603003.pdf
[77 KB]
Research Grade Blood Pressure Transducer Manual
78% Login to view 724488 724489.pdf
[124 KB]
Research Grade Blood Pressure Transducer Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews