Home Anesthesia Equipment Anesthesia Circuits Rodent Anesthesia Circuit Mask


Larger Views

 

Rodent Anesthesia Circuit Mask
Developed in conjunction with leading research facilities, the Rodent circuit is the most effective, user-friendly, mask for rodents. Available with 3 different size diaphragms, the mask easily fits most rodents. With the use of a C-Pram circuit shown below, the mask is designed to deliver and evacuate the gas through one tube.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
723026 Circuit Set, Rodent (hose, mask and medium diaphragm) Yes -- View Pricing
Login to Shop
723027 Mask, Rodent (no diaphragm) -- - View Pricing
Login to Shop
723028 Rodent Mask Diaphragm Small (7/16 in DIA) -- - View Pricing
Login to Shop
723029 Rodent Mask Diaphragm Medium (9/16 in DIA) Yes -- View Pricing
Login to Shop
723030 Rodent Mask Diaphragm Large (3/4 in) DIA) -- - View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Unique circuit designed specifically for rodent anesthesia
• Best suited for use with Multi-station Research Anesthesia System, see page F19
• Will work with any non-rebreathing anesthesia machine

Developed in conjunction with leading research facilities, the Rodent circuit is the most effective, user-friendly, mask for rodents. Available with 3 different size diaphragms, the mask easily fits most rodents. With the use of a C-Pram circuit shown below, the mask is designed to deliver and evacuate the gas through one tube. Traditionally, the open mask system has caused problems because of the contamination of waste gas to the staff and the patient rebreathing CO2. These problems are avoided with the Rodent circuit and mask design. When combined with in-house suction or the Lab Animal Evacuation System or F/Air canister, see page F19, there is minimal risk of untoward anesthetic agent exposure for the researcher. Inlet tubing: 6.25 mm (0.25 in) ID, silicone tubing. Outlet from rodent circuit is a 22 mm (0.866 in) respiratory fitting. Respiratory Adapters are available to connect the rodent circuit outlet to tubing of various sizes from 6 to 15 mm ID, see page F22.


Specifications Back to Top

Specifications723026723027723028723029723030
Diameter English9/16 in*na in7/16 in9/16 in3/4 in
Inlet Tubing ID English0.25 in0.25 in0.25 in0.25 in*na in
Inlet Tubing ID Metric6.25 mm6.25 mm6.25 mm6.25 mm*na mm
MaterialSilicone TubingSilicone TubingSilicone TubingSilicone TubingSilicone Tubing
Outlet Respiratory Fitting English0.866 in0.866 in0.866 in0.866 in*na in
Outlet Respiratory Fitting Metric22 mm22 mm22 mm22 mm*na mm

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 11 results for Rodent Anesthesia Circuit Mask   Page 1  2 

Score

Document

Description

100% Login to view VT22 Rodent Ventilator.pdf
[194 KB]
Rodent Ventilator use in finding arterior wall PO2 and nitric oxide release during sympathetic vasoconstriction in the rat intestine
37% Login to view VT30 Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1.pdf
[366 KB]
Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1
35% Login to view VT12 Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice.pdf
[184 KB]
Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice
34% Login to view VT14 Rodent Ventilator.pdf
[440 KB]
PDMI-2 Microincubator use in Airway surface liquid pH in well-differentiated airway epithelial cell cultures and mouse trachea
30% Login to view VT03 Rodent Ventilator use in finding Reduced PO2 and Adenosine Formation Preserve Arteriolar Nitric Oxide.pdf
[283 KB]
Rodent Ventilator use in finding Ventilatory and metabolic responses to hypoxia in the smallest simian primate, the pygmy marmoset
29% Login to view VT12 mini 2002hs.pdf
[177 KB]
Small rodent ventilator use in finding chronic measurement of cardiac output in conscious mice
27% Login to view VT30 ventilator.pdf
[360 KB]
Rodent Ventilator use in Antisense Knockdown of the Gial Glutamate Transporter GLT-1
24% Login to view VT04 683.pdf
[298 KB]
Rodent Ventilator use in finding Ventilatory and metabolic responses to hypoxia in the smallest simian primate, the pygmy marmoset
24% Login to view VT10 683 atr.pdf
[124 KB]
Rodent Resiprator use in finding Arteriolar reactivity and capillarization in chronically stimulated rat limb skeletal muscle post-MI
22% Login to view VT03 Model 683 Ventilator.pdf
[274 KB]
Rodent Ventilator use in finding Reduced PO2 and Adenosine Formation Preserve Arteriolar Nitric Oxide
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1 result for Rodent Anesthesia Circuit Mask  

Score

Document

Description

100% Login to view Anesthesia Selection Guide.pdf
[28 KB]
BS4_F_Respiration.qxd
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews