Train Delay Generators

The DG2A is a compact, free-standing, battery powered instrument which can be used to generate trigger pulses required for repetitive stimulation. Also featuring DELAY controls, it is useful for determining nerve or axonal Effective Refractory Period (ERP) through the production of a delayed second pulse.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
650641 Train Delay Generator DG2A -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Trigger timing generator
• Ideal for electrophysiology
• Perfect match for DS2A and DS3
• Internal battery

The DG2A is a compact, free-standing, battery powered instrument which can be used to generate trigger pulses required for repetitive stimulation. Also featuring DELAY controls, it is useful for determining nerve or axonal Effective Refractory Period (ERP) through the production of a delayed second pulse.

Various modes allow output pulses to be produced singularly (SINGLE), continuously (FREE-RUN & GATED) or in a burst (TRAIN), with the burst/train duration and pulse frequency determined by the front panel controls. In each of the modes (except FREE-RUN), outputs can be initiated either by the front panel push button, a TTL compatible trigger/gating pulse or a suitable foot switch.

The unit has control of train duration over three full decades, pulse repetition rate (or frequency) within that train over five decades and control of the delayed pulse over three decades. It has two BNC output sockets (i) the SYNC output produces a pulse to trigger recording devices or synchronize other equipment and (ii) the OUT output produces either a delayed version of the same or by toggle switch selection, pairs of delayed and non-delayed pulses (as would be necessary for ERP studies).

The unit is especially suitable for use with our DS2A Isolated Constant Voltage and DS3 Isolated Current Isolated Stimulators which have their own Pulse Duration controls.

The instrument is powered by an internal 9V battery (PP3 - 6R61 style) and replaces our DG2 Trigger Generator.

A mounting frame (part number BS4 65-0337) is available so that two units of either DG2A, DS2A or DS3 can be mounted in 19” rack. See page H53 for DS2A and DS3 stimulators. The unit always produces a pulse to synchronize other equipment at SYNC and a pulse delayed from SYNC by DELAY controls. Note: No other accessories, other than a battery, are supplied.


Specifications Back to Top

Specifications650641
CertificationsCE
Delay: Accuracy±1% at ‘1’ and ‘12’ marks, ±5% at intermediate marks
Delay: ControlSingle turn control marked 1 - 12 msec with intermediate integer panel marks
Delay: Total Range1 - 1200 msec in three overlapping ranges
Depth English2.4 in
Depth Metric60 mm
Duration: Accuracy±1% at ‘1’ and ‘12’ marks, ±5% at intermediate marks
Duration: ControlSingle turn control marked 1 – 12 sec with intermediate integer panel marks
Duration: Internal JumperEnable “x10” - giving a 100 msec - 120 sec total range
Duration: Multiplierx0.01 ; x0.1 ; x1
Duration: Total Range10 msec - 12 sec in three overlapping ranges
Height English4.3 in
Height Metric110 mm
Input: ConnectorBNC socket
Input: Indicator“TOO FAST” Red LED that flashes if a Trigger is received while the unit is busy
Input: Internal JumperEnable “Active Low” - allowing for an Input that is Low during its active phase
Input: LevelsTTL high (>1.5 V), TTL low (<0.8 V)
Input: PolarityActive High (GATE/TRAIN) and Positive edge (SINGLE) or Active Low and Negative edge by Internal Jumper
Input: Push-buttonHas same function as a valid input signal
Modes: Control FunctionsFour position rotary switch
Modes: FREE-RUNContinuous Output pulses as set by REPETITION controls
Modes: GATEDInput signal enables unit to produce pulses as set by REPETITION controls
Modes: SINGLEInput signal triggers a single Output pulse
Modes: TRAINInput signal Triggers unit to produce pulses as set by REPETITION controls for the time as set by the DURATION controls
Multiplier: Indicator“TOO LONG” Red LED that flashes if DELAY longer than can be produced for each pulse
Multiplier: Internal JumperEnable “x10” - giving a 10 msec - 12 s total range
Outputs - OUT: ConnectorSelection of only the Delayed pulse (upwards) or both the Sync and Delayed pulses
Outputs - OUT: ControlSelection of only the Delayed pulse (upwards) or both the Sync and Delayed pulses
Outputs - OUT: IndicatorAmber LED that flashes for each OUT output pulse
Outputs - OUT: Internal JumperEnable “Active Low” - giving an Output that is Low during its active phase
Outputs - OUT: SignalPositive going, 200µs pulse, TTL compatible pulse (5 V amplitude)
Outputs - SYNC: ConnectorBNC socket
Outputs - SYNC: SignalPositive going, 200µs pulse, TTL compatible pulse (5 V amplitude)
Power: Battery Life250 Hours with EverReady 6LF22 or Duracell MN1604
Power: Consumption< 2 mA
Power: ControlON/OFF toggle: OFF is down
Power: InternalPP3 - (IEC-6LR61) style, alkaline preferred
Repetition (Frequency): Accuracy±1% at ‘1’ and ‘12’ marks, ±5% at intermediate marks
Repetition (Frequency): ControlSingle turn control marked 1 – 12 Hz with intermediate integer panel marks
Repetition (Frequency): Multiplierx0.01 ; x0.1 ; x1 ; x10 ; x100
Repetition (Frequency): Total Range0.01 - 1200 Hz in five overlapping ranges
Weight English17.3 oz
Weight Metric490 g
Width English7.4 in
Width Metric188 mm

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 10 results for Train Delay Generators  

Score

Document

Description

100% Login to view ATP Crossing the Cell Plasma Membrane Generates an Ionic Current.pdf
[140 KB]
PL-100 use in ATP Crossing the Cell Plasma Membrane Generates an Ionic Current in Xenopus Oocytes
54% Login to view PP30 Infusion Pump.pdf
[265 KB]
Hippocampus and Trace Fear Conditioning
47% Login to view HB03 Leukotriene B4 Promotes Reactive Oxidant Generation and Leukocyte Adherence During Acute Hypoxia.pdf
[198 KB]
Homeothermic Blanket Leukotrience B4 promotes reactive oxidant generation and leukocyte adherence during acute hypoxia
40% Login to view HS10TY 1.PDF
[204 KB]
Pharmacological block of the slow component of the outward delayed rectifier fails to lengthen rabbit ventricular muscle and action potential duration
35% Login to view PI09 PLI100 Med System.pdf
[133 KB]
PL-100 use in ATP Crossing the Cell Plasma Membrane Generates an Ionic Current in Xenopus Oocytes
33% Login to view HB03 Homeothermic Blanket.pdf
[216 KB]
Homeothermic Blanket Leukotrience B4 promotes reactive oxidant generation and leukocyte adherence during acute hypoxia
33% Login to view BTX10 ECM2001.pdf
[244 KB]
Hybrids of Dendritic Cells and Tumor Cells Generated by Eloctrofusion
27% Login to view PP30 Post-Training Excitotoxic Lesions of Dorsal Hippocampus Attenuate Forward Trace.pdf
[261 KB]
Hippocampus and Trace Fear Conditioning
20% Login to view HS09TY 1.PDF
[1.3 MB]
Sarcoplasmic Reticulim Ca2+ Uptake and Release
10% Login to view HS10TY IKs block fails to lengthen QTc and APD in rabbit.pdf
[207 KB]
Pharmacological block of the slow component of the outward delayed rectifier fails to lengthen rabbit ventricular muscle and action potential duration
   

Back to Top



Manuals Back to Top

Displaying 1 to 1 of 1 result for Train Delay Generators  

Score

Document

Description

100% Login to view Foot Switch 0908.pdf
[453 KB]
Generator Footswitch User's Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews