Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Biological Measurement Products Nitric Oxide Measurement Systems 1-Channel Nitric Oxide Measurement System


Larger Views

 

1-Channel Nitric Oxide Measurement System
The ‘inNO-T’ system is the most technologically advanced nitric oxide electrochemical detection system on the market today. It combines a nitric oxide configured potentiostat and a sophisticated software controlled data acquisition system in one compact battery powered unit. When used with the ‘amiNO’ series of NO sensors, this unit provides an NO detection sensitivity increase of up to 100 times that of any other electrochemical detection system on the market today. Its state of the art battery powered design allows the unit to run continuously for up to 5 years, making it ideal for any electrically isolated and/or portable application.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
693050 inNO-T Nitric Oxide Measurement System #1, 1-Channel, 115 VAC -- 5 days View Pricing
Login to Shop
693052 inNO-T Nitric Oxide Measurement System #2, 1-Channel, 115 VAC -- 5 days View Pricing
Login to Shop
690048 inNO-T Nitric Oxide Measurement System #3, 1-Channel, 115 VAC -- 5 days View Pricing
Login to Shop
690050 inNO-T Nitric Oxide Measurement System #4, 1-Channel, 115 VAC -- 5 days View Pricing
Login to Shop
693051 inNO-T Nitric Oxide Measurement System #1, 1-Channel, 230 VAC -- 5 days View Pricing
Login to Shop
693053 inNO-T Nitric Oxide Measurement System #2, 1-Channel, 230 VAC -- 5 days View Pricing
Login to Shop
690049 inNO-T Nitric Oxide Measurement System #3, 1-Channel, 230 VAC -- 5 days View Pricing
Login to Shop
690051 inNO-T Nitric Oxide Measurement System #4, 1-Channel, 230 VAC -- 5 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• NEW Dual Channel System
• Uses ‘amiNO’ sensors which are up to 100 times more sensitive than others on the market today
• inNO-T system is the first available NO system to have temperature compensation
• inNO-T system virtually eliminates base line drift due to temperature changes
• Combination NO meter and data acquisition system
• Battery-powered benchtop/portable system (5 year battery life)
• 24 bit A/D converter for the widest dynamic range (16,000,000 to 1)
• User friendly recording, playback and analysis
• Software compatible with Windows™ 95/98, 2000 and NT
• Continuous recordings (over 1 month)
• System shipped complete with NO meter, software, 2 types of NO sensors, and calibration kit
• Auto zero
• Computer chart recorder
• RS-232 interface
• Digital filter
• Menu driven commands

The ‘inNO-T’ system is the most technologically advanced nitric oxide electrochemical detection system on the market today. It combines a nitric oxide configured potentiostat and a sophisticated software controlled data acquisition system in one compact battery powered unit. When used with the ‘amiNO’ series of NO sensors, this unit provides an NO detection sensitivity increase of up to 100 times that of any other electrochemical detection system on the market today. Its state of the art battery powered design allows the unit to run continuously for up to 5 years, making it ideal for any electrically isolated and/or portable application.
The ‘inNO-T’ system is the first available nitric oxide system to include temperature compensation which further enhances the detection limits and data reliability by virtually eliminating baseline drift caused by temperature changes. A temperature probe is supplied with each system. Its internal 24 bit analog to digital converter and built in digital notch filtering allows for accurate, noise free, detection of Nitric Oxide levels of less than 0.01 nM. The 24 bit A/D technology also gives the unit a dynamic range in excess of 16,000,000 to 1. Its sophisticated control and analysis software can be linked to any computer system that utilizes Windows™ 95/98, 2000 or NT via the ‘inNO’s’ internal RS-232 interface.


Specifications Back to Top

Specifications693050693052690048690050693051693053690049690051
CerificationsCECECECECECECECE
Concentration Scale±1,000,000.0 nM±1,000,000.0 nM±1,000,000.0 nM±1,000,000.0 nM±1,000,000.0 nM±1,000,000.0 nM±1,000,000.0 nM±1,000,000.0 nM
Current Scale±2,500,000.0 pA±2,500,000.0 pA±2,500,000.0 pA±2,500,000.0 pA±2,500,000.0 pA±2,500,000.0 pA±2,500,000.0 pA±2,500,000.0 pA
Depth English8 in8 in8 in8 in8 in8 in8 in8 in
Depth Metric203 mm203 mm203 mm203 mm203 mm203 mm203 mm203 mm
Height English3 in3 in3 in3 in3 in3 in3 in3 in
Height Metric76 mm76 mm76 mm76 mm76 mm76 mm76 mm76 mm
PowerReplaceable batteryReplaceable batteryReplaceable batteryReplaceable batteryReplaceable batteryReplaceable batteryReplaceable batteryReplaceable battery
Recording Speed1 to 1000 sec/div1 to 1000 sec/div1 to 1000 sec/div1 to 1000 sec/div1 to 1000 sec/div1 to 1000 sec/div1 to 1000 sec/div1 to 1000 sec/div
Resolution English0.1 pA0.1 pA0.1 pA0.1 pA0.1 pA0.1 pA0.1 pA0.1 pA
Resolution Metric0.01 nM0.01 nM0.01 nM0.01 nM0.01 nM0.01 nM0.01 nM0.01 nM
Screen Meter7.5 digit meter7.5 digit meter7.5 digit meter7.5 digit meter7.5 digit meter7.5 digit meter7.5 digit meter7.5 digit meter
Temperature Range Metric0 to 50 °C, inNO-T only0 to 50 °C, inNO-T only0 to 50 °C, inNO-T only0 to 50 °C, inNO-T only0 to 50 °C, inNO-T only0 to 50 °C, inNO-T only0 to 50 °C, inNO-T only0 to 50 °C, inNO-T only
Temperature Resolution Metric0.01 °C, inNO-T only0.01 °C, inNO-T only0.01 °C, inNO-T only0.01 °C, inNO-T only0.01 °C, inNO-T only0.01 °C, inNO-T only0.01 °C, inNO-T only0.01 °C, inNO-T only
Temperature Sensor< 0.50 mm tip, 120 mm long, inNO-T only< 0.50 mm tip, 120 mm long, inNO-T only< 0.50 mm tip, 120 mm long, inNO-T only< 0.50 mm tip, 120 mm long, inNO-T only< 0.50 mm tip, 120 mm long, inNO-T only< 0.50 mm tip, 120 mm long, inNO-T only< 0.50 mm tip, 120 mm long, inNO-T only< 0.50 mm tip, 120 mm long, inNO-T only
Width English9 in9 in9 in9 in9 in9 in9 in9 in
Width Metric229 mm229 mm229 mm229 mm229 mm229 mm229 mm229 mm

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 45 results for 1-Channel Nitric Oxide Measurement System   Page 1  2  3  4  5 

Score

Document

Description

100% Login to view Noninvasive measurement of the pH of the endoplasmic reticulum.PDF
[372 KB]
Noninvasive measurement of the pH of the endoplasmic reticulum at rest and during calcium release
95% Login to view ET1 Subminiature Electrode.pdf
[161 KB]
Nitric Oxide Increases Glucose Uptake
87% Login to view HS17 Multi Pen Recorder.pdf
[148 KB]
Multi Pen Recorder use in determining Airway Nitric Oxide Levels in Cystic Fibrosis Patients
85% Login to view HS20 Mini Ventilator.pdf
[681 KB]
Mini Ventilator used in Nitric oxide prevention of cardiovascular disease
81% Login to view NO02 hearing.pdf
[518 KB]
The Electrochemical and fluorescene detection of nitric oxide in the cochlea and its increase following loud sound
81% Login to view NO05.pdf
[200 KB]
Microelectrode used in Platelet Nitric Oxide and Superoxide Release During the Developement of Nitrate Tolerance
81% Login to view PP58 Pump.pdf
[127 KB]
Endothelium-Derived Nitric Oxide Regulates Arterial Elasticity in Human Arteries In Vivo
80% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
76% Login to view VT22 Rodent Ventilator.pdf
[194 KB]
Rodent Ventilator use in finding arterior wall PO2 and nitric oxide release during sympathetic vasoconstriction in the rat intestine
72% Login to view HS20 Nitric Oxide prevents cardiovascular disease.pdf
[682 KB]
pq210011609p
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for 1-Channel Nitric Oxide Measurement System  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
70% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews