Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Delivery & Sampling Products Catheters SoloCath™ CBAS Heparin Coated Polyurethane Catheter


Larger Views

 

SoloCath™ CBAS Heparin Coated Polyurethane Catheter
Clear, rounded distal tip, two movable suture bulbs and attachment sleeve.
CBAS™ Long-Term Heparin Coating
The Carmeda BioActive Surface (CBAS™) is the product of Carmeda AB in Stockholm, Sweden. Carmeda has an extensive bibliography of CBAS™ applications, particularly in human-use devices. CBAS™ applications in humans include central venous catheters, coronary stents, ventricular assist devices, extracorporeal blood circuits, blood sampling devices, and vascular grafts. CBAS™ is used to coat devices from J&J, Medtronic, and Gore. In lab animal research, CBAS™-coated catheters are used for arterial and venous access. Also, CBAS™ provides dramatic improvement in catheter patency for chronic lymphatic access.

Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles
Item# Description In Stock Lead Time U.S. List Price Quantity
724403 CBAS™ Heparin Coated Polyurethane, 3 Fr, 60 cm, no Luer, pkg. of 1 -- 10 days View Pricing
Login to Shop
724404 CBAS™ Heparin Coated Polyurethane, 3.5 Fr, 60 cm, no Luer, pkg. of 1 -- 10 days View Pricing
Login to Shop
724405 CBAS™ Heparin Coated Polyurethane, 5 Fr, 60 cm, no Luer, pkg. of 1 -- 10 days View Pricing
Login to Shop
724406 CBAS™ Heparin Coated Polyurethane, 7 Fr, 60 cm, no Luer, pkg. of 1 -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Venous access
• Arterial access
• Blood collection circuits
• Lymphatic access

CBAS™ Long-Term Heparin Coating
The Carmeda BioActive Surface (CBAS™) is the product of Carmeda AB in Stockholm, Sweden. Carmeda has an extensive bibliography of CBAS™ applications, particularly in human-use devices. CBAS™ applications in humans include central venous catheters, coronary stents, ventricular assist devices, extracorporeal blood circuits, blood sampling devices, and vascular grafts. CBAS™ is used to coat devices from J&J, Medtronic, and Gore. In lab animal research, CBAS™-coated catheters are used for arterial and venous access. Also, CBAS™ provides dramatic improvement in catheter patency for chronic lymphatic access.
How It Works
CBAS™ is a patented process for applying heparin to the surfaces of biomaterials. Unlike TDMAC heparin, the CBAS™ covalent bonds last several months. The “active sequence” of the heparin molecule serves to halt the clotting cascade.
The endothelial lining of blood vessels contains a heparin-like substance which performs like CBAS™. The novel aspect of CBAS™ is that the active sequence remains available over and over to bind with antithrombin. No other coating can achieve this long-term function.
CBAS™ is the most respected thromboresistant coating available in the human-use medical device industry. It is under license for use in laboratory animal research applications. Unlike hydrogels, CBAS™ is bioactive, not passive. It has been proven repeatedly to minimize the thrombogenecity of intravascular devices.
Long-Term, Non-Leaching
CBAS™ is not consumed. The heparin "active sequence" repeatedly binds to antithrombin to prevent clotting. As such, half-life is not an issue. CBAS™ is "end-point attached" to the catheter surface and does not elute into the bloodstream.
1) CBAS™ heparin "active sequence" is available to bind with antithrombin.
2) Antithrombin conforms to accelerate binding with thrombin and other coagulation factors.
3) Coagulation effect of thrombin is neutralized by formation of thrombin-antithrombin complex.
4) Thrombin-antithrombin complex washes away. CBAS™ heparin “active sequence” remains intact and is available repeatedly to bind with antithrombin.
Reduces Infections
Human clinical studies using CBAS™ and other heparin coatings document a clear anti-infective benefit from heparin coatings. While heparin is not an antimicrobial per se, it does remove the blood nidus for microorganisms thereby minimizing the nutrients and binding sites for many of the unfavorable blood proteins. Appelgren et al demonstrated a 50% reduction in infections from CBAS™ coated catheters in humans. Visit www.carmeda.com for additional information and complete CBAS™ bibliography (200+ references). • Most thromboresistant material
• Rounded distal tip is less traumatic to intimal lining of blood vessels
We offer a full range of silicone, polyurethane and heparin coated polyurethane catheters in sizes for all species. With nearly 20 years of experience designing and manufacturing laboratory animal catheters, we can help you choose the the ideal catheter for your application.
Biomaterials
Silicone rubber continues to be the most popular catheter material; however, polyurethanes have been proven to be more hemocompatible than silicone. The CBAS™ heparin-coated polyurethane has proven to be the most thromboresistant of all available technologies.
Rounded Tips
We recommend rounded tips for intravascular catheters as they are less traumatic to the intimal lining of blood vessels. The sharp edges on square-cut or bevel-cut catheters can irritate the vessel's intimal lining and hasten the host's thrombogenic response.
Additional catheter options include retention beads, suture flanges, depth markings, and special holes and slits for organ perfusion, bladder and gastro-intestinal catheterization.


Specifications Back to Top

Specifications724403724404724405724406
Applications (appropriate for jugular vein, caraoid artery, femoral artery/vein)Rat 200-350g, Nonhuman Primate <1kgRat 200-350g, Nonhuman Primate <1kgCat, Rabbit, Dog >8kg, Mini-Pig (adult), Nonhuman Primate 3 to >5kgDog >8kg, Mini-Pig (adult), Pig (adult), Nonhuman Primate >5kg
FeaturesNo LuerNo LuerNo LuerNo Luer
ID English0.024 in0.024 in0.040 in0.052 in
ID Metric0.610 mm0.610 mm1.020 mm1.320 mm
Length Metric60 cm60 cm60 cm60 cm
MaterialCBAS Heparin Coated PolyurethaneCBAS Heparin Coated PolyurethaneCBAS Heparin Coated PolyurethaneCBAS Heparin Coated Polyurethane
OD English0.038 in0.038 in0.066 in0.096 in
OD Metric0.970 mm0.970 mm1.680 mm2.430 mm
Proximal Size3 Fr3 Fr5 Fr7 Fr

Back to Top



Journal Articles Back to Top

Displaying 1 to 3 of 3 results for SoloCath™ CBAS Heparin Coated Polyurethane Catheter  

Score

Document

Description

100% Login to view VT15 Piston Respirator.pdf
[244 KB]
Interaction of Secretory Leukocyte Protease Inhibitor with Heparin Inhibits Proteases Involved in Asthma with use of Piston Respirator
94% Login to view TD06 BP.1pdf.pdf
[93 KB]
Arterial Vascual Catheter use in finding Effects of Benazepril
26% Login to view HS04 Contractile Efficiency in Hibernating Myocardium.pdf
[79 KB]
Latex Balloon use in finding Benefical Effect of Glucose on Short-Term, Perfusion-Pressure Induced Changes of Contractile Efficiency in Isolated Rabbit Hearts
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews