Home Behavior Research Products Activity Monitoring Systems Metabolic Monitoring System


Larger Views

 

Metabolic Monitoring System
This Metabolic Monitoring System is ideal for measurement of oxygen consumption and carbon dioxide production in lab animals. It uses open circuit calorimetry technique. It is very flexible, the size of the animal is immaterial. The data can be analyzed by the statistical packages. The system comes with windows based software.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
727206 1 Channel Metabolic Monitoring System, Includes 2 Channel Flow Controller and 2 Drierite Columns -- 10 days View Pricing
Login to Shop
727207 2 Channel Metabolic Monitoring System, Includes 3 Channel Flow Controller and 3 Drierite Columns -- 10 days View Pricing
Login to Shop
727208 4 Channel Metabolic Monitoring System, Includes 5 Channel Flow Controller and 5 Drierite Columns -- 10 days View Pricing
Login to Shop
727209 6 Channel Metabolic Monitoring System, Includes 7 Channel Flow Controller and 7 Drierite Columns -- 10 days View Pricing
Login to Shop
727210 8 Channel Metabolic Monitoring System, Includes 9 Channel Flow Controller and 9 Drierite Columns -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Oxygen consumption, VO2
• Carbon dioxide production, VCO2
• Respiratory exchange ratio, CO2/VO2
• Calorimetry
• Positive/Negative pressure systems available
• Respiration rate
• Windows based software

This Metabolic Monitoring System is ideal for measurement of oxygen consumption and carbon dioxide production in lab animals. It uses open circuit calorimetry technique. It is very flexible, the size of the animal is immaterial. The data can be analyzed by the statistical packages. The system comes with windows based software.
Up to eight animal cages can be monitored simultaneously. An animal is placed in the cage and the lid is lightly shut to provide a partial seal. Ambient air is pumped through the cage. The amount of air entering the cage is precisely measured by a mass flow meter (STP 0ºC and 760 mmHg), and is traceable to the National Bureau of Standards. Most of the exhaust air goes to the atmosphere. A small sample of the exhaust is monitored for O2 and CO2 content by zirconia sensors. These sensors are very accurate and maintenance free. Unlike electrochemical cells, zirconia cells provide higher accuracy and do not have to be replaced.
The system described above generates small positive pressures within the animal cages and is generally known as a positive pressure system. For some experiments, a negative pressure system is more appropriate. Both systems are offered.
O2 consumption and CO2 production are calculated on the basis of known gas fractions both at the input and the exhaust ports of the cage and with the amount of air flowing through the cage.
Parameters Measured
The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr).
Options
This Metabolic Monitor System can be used simultaneously with the Animal Activity Monitoring System, see pages G2 - G3, for ambulatory activity and a Treadmill for exercise. The modular construction of the products allows for monitoring one to four animals in the standard model. On special requests the systems can be expanded to eight animals.
The combination of the Metabolic Monitor and Activity Monitoring System permits measurement of metabolic rate and animal locomotor activity simultaneously, thus allowing correlation between activity and metabolic rate. The Activity Monitoring Systems measures both horizontal and vertical activity.
The combination of this Metabolic Monitor and the Animal Treadmill, see page G15, is useful for measuring Work (W) and fatigue points in conjunction with metabolic rate. The Treadmill is an animal exerciser with a shocker. Both the speed and the angle of inclination of the exerciser are user adjustable
This Metabolic Monitoring System can also be integrated with the Food and Liquid Consumption Monitor, see pages G6 - G7, to measure the correlation between food and liquid intake and metabolic rate.
Each Metabolic Monitoring System includes a metabolic monitoring system analyzer, O2 analyzer, CO2 analyzer, custom designed air tight animal test chamber and Win-2000/XP Based Software.


Specifications Back to Top

Specifications727206727207727208727209727210
Carbon Dioxide Sensor: Accuracy±0.025% CO2±0.025% CO2±0.025% CO2±0.025% CO2±0.025% CO2
Carbon Dioxide Sensor: DriftAuto zero before each sample eliminates zero driftAuto zero before each sample eliminates zero driftAuto zero before each sample eliminates zero driftAuto zero before each sample eliminates zero driftAuto zero before each sample eliminates zero drift
Carbon Dioxide Sensor: Range0% to 2% CO20% to 2% CO20% to 2% CO20% to 2% CO20% to 2% CO2
Carbon Dioxide Sensor: Repeatability±0.01% CO2±0.01% CO2±0.01% CO2±0.01% CO2±0.01% CO2
Carbon Dioxide Sensor: Resolution0.001% CO20.001% CO20.001% CO20.001% CO20.001% CO2
Carbon Dioxide Sensor: Response Time2.5 sec2.5 sec2.5 sec2.5 sec2.5 sec
Carbon Dioxide Sensor: Sample Flow Rate200 ml/min200 ml/min200 ml/min200 ml/min200 ml/min
Carbon Dioxide Sensor: Temperature Coefficient005%/degree C005%/degree C005%/degree C005%/degree C005%/degree C
Carbon Dioxide Sensor: TypeNon-dispersive infrared NDIRNon-dispersive infrared NDIRNon-dispersive infrared NDIRNon-dispersive infrared NDIRNon-dispersive infrared NDIR
Dimensions: CagesCustom designedCustom designedCustom designedCustom designedCustom designed
Dimensions: Carbon Dioxide Analyzer, L x W x H English10.5 x 12 x 5.5 in10.5 x 12 x 5.5 in10.5 x 12 x 5.5 in10.5 x 12 x 5.5 in10.5 x 12 x 5.5 in
Dimensions: Carbon Dioxide Analyzer, L x W x H Metric26.67 x 30.48 x 13.97 cm26.67 x 30.48 x 13.97 cm26.67 x 30.48 x 13.97 cm26.67 x 30.48 x 13.97 cm26.67 x 30.48 x 13.97 cm
Dimensions: Flow Controller, L x W x H English(14.5 x 19.5 x 7 in(14.5 x 19.5 x 7 in(14.5 x 19.5 x 7 in(14.5 x 19.5 x 7 in(14.5 x 19.5 x 7 in
Dimensions: Flow Controller, L x W x H Metric36.83 x 49.53 x 17.78 cm36.83 x 49.53 x 17.78 cm36.83 x 49.53 x 17.78 cm36.83 x 49.53 x 17.78 cm36.83 x 49.53 x 17.78 cm
Dimensions: Oxygen Analyzer, L x W x H English10.5 x 12 x 5.5 in10.5 x 12 x 5.5 in10.5 x 12 x 5.5 in10.5 x 12 x 5.5 in10.5 x 12 x 5.5 in
Dimensions: Oxygen Analyzer, L x W x H Metric26.67 x 30.48 x 13.97 cm26.67 x 30.48 x 13.97 cm26.67 x 30.48 x 13.97 cm26.67 x 30.48 x 13.97 cm26.67 x 30.48 x 13.97 cm
Dimensions: Statistical Analyzer, L x W x H English10 x 10.75 x 4 in10 x 10.75 x 4 in10 x 10.75 x 4 in10 x 10.75 x 4 in10 x 10.75 x 4 in
Dimensions: Statistical Analyzer, L x W x H Metric25.4 x 27.31 x 10.16 cm25.4 x 27.31 x 10.16 cm25.4 x 27.31 x 10.16 cm25.4 x 27.31 x 10.16 cm25.4 x 27.31 x 10.16 cm
Flow Pumps VacuumCapacity 5 SLPM/20 SLPMCapacity 5 SLPM/20 SLPMCapacity 5 SLPM/20 SLPMCapacity 5 SLPM/20 SLPMCapacity 5 SLPM/20 SLPM
Humidity0% to 90% relative humidity non-condensing0% to 90% relative humidity non-condensing0% to 90% relative humidity non-condensing0% to 90% relative humidity non-condensing0% to 90% relative humidity non-condensing
Mass Flow Meter: Accuracyneg 0.01 SLPMneg 0.01 SLPMneg 0.01 SLPMneg 0.01 SLPMneg 0.01 SLPM
Mass Flow Meter: Repeatabilityneg 0.02 SLPMneg 0.02 SLPMneg 0.02 SLPMneg 0.02 SLPMneg 0.02 SLPM
Mass Flow Meter: Resolution0.001 SLPM0.001 SLPM0.001 SLPM0.001 SLPM0.001 SLPM
Mass Flow Meter: Thermal Range0 to 5 SLPM/0 to 20 SLPM0 to 5 SLPM/0 to 20 SLPM0 to 5 SLPM/0 to 20 SLPM0 to 5 SLPM/0 to 20 SLPM0 to 5 SLPM/0 to 20 SLPM
Oxygen Sensor: Accuracy±0.005% O2±0.005% O2±0.005% O2±0.005% O2±0.005% O2
Oxygen Sensor: Drift0.005% O2 over 24 hours0.005% O2 over 24 hours0.005% O2 over 24 hours0.005% O2 over 24 hours0.005% O2 over 24 hours
Oxygen Sensor: Humidity0% to 90% Relative humidity non condensing0% to 90% Relative humidity non condensing0% to 90% Relative humidity non condensing0% to 90% Relative humidity non condensing0% to 90% Relative humidity non condensing
Oxygen Sensor: Pressure CoefficientNegligibleNegligibleNegligibleNegligibleNegligible
Oxygen Sensor: Range18% to 22% O2 standard (0% to 100% O2 available by special order)18% to 22% O2 standard (0% to 100% O2 available by special order)18% to 22% O2 standard (0% to 100% O2 available by special order)18% to 22% O2 standard (0% to 100% O2 available by special order)18% to 22% O2 standard (0% to 100% O2 available by special order)
Oxygen Sensor: Repeatability±0.005% O2±0.005% O2±0.005% O2±0.005% O2±0.005% O2
Oxygen Sensor: Resolution0.001% O20.001% O20.001% O20.001% O20.001% O2
Oxygen Sensor: Response Time0.3 seconds0.3 seconds0.3 seconds0.3 seconds0.3 seconds
Oxygen Sensor: Sample Flow Rate200 ml/Min200 ml/Min200 ml/Min200 ml/Min200 ml/Min
Oxygen Sensor: Temperature CoefficientNegligibleNegligibleNegligibleNegligibleNegligible
Oxygen Sensor: TypeZirconiaZirconiaZirconiaZirconiaZirconia
Parameters MeasuredThe following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr)The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr)The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr)The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr)The following parameters are measured in the standard model: Oxygen consumption (mL/kg/hr), carbon dioxide production (mL/kg/hr), respiratory exchange ratio (CO2/VO2) and heat Kcal/hr)
Response Time0.25 seconds0.25 seconds0.25 seconds0.25 seconds0.25 seconds
Temperature and PressureEffects are eliminated by sensor design and computer compensationEffects are eliminated by sensor design and computer compensationEffects are eliminated by sensor design and computer compensationEffects are eliminated by sensor design and computer compensationEffects are eliminated by sensor design and computer compensation
Weight (Drierite Columns) English2.5 lbs2.5 lbs2.5 lbs2.5 lbs2.5 lbs
Weight (Drierite Columns) Metric1.13 kg1.13 kg1.13 kg1.13 kg1.13 kg
Weight (all analyzers) English12 lbs12 lbs12 lbs12 lbs12 lbs
Weight (all analyzers) Metric5.44 kg5.44 kg5.44 kg5.44 kg5.44 kg
Weight (cages) English6 lbs6 lbs6 lbs6 lbs6 lbs
Weight (cages) Metric2.72 kg2.72 kg2.72 kg2.72 kg2.72 kg
Weight (flow controller) English39 lbs39 lbs39 lbs39 lbs39 lbs
Weight (flow controller) Metric17.69 kg17.69 kg17.69 kg17.69 kg17.69 kg

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 22 results for Metabolic Monitoring System   Page 1  2  3 

Score

Document

Description

100% Login to view MC01 Metabolic Cages.pdf
[340 KB]
Metabolic Cages use in finding Impaired Stratum Corneum Hydration in Mice Lacking Epidermal Water Channel Aquaporin-3
72% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
36% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
29% Login to view MC01 Impaired Stratum Corneum Hydration in Mice Lacking Epidermal Water Channel Aquaporin-3.pdf
[339 KB]
Metabolic Cages use in finding Impaired Stratum Corneum Hydration in Mice Lacking Epidermal Water Channel Aquaporin-3
27% Login to view MC02 Species Differences in Pharmacokinetics of a Hepatoprotective Agent.pdf
[168 KB]
Respiration Metabolic Cage use in finding species differences in Pharmacokinetics of a Hepatoprotective agent
20% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
18% Login to view VT04 683.pdf
[298 KB]
Rodent Ventilator use in finding Ventilatory and metabolic responses to hypoxia in the smallest simian primate, the pygmy marmoset
18% Login to view Expression of Functional Metabotropic Glutamate Receptors.pdf
[229 KB]
Expression of Functional Metabolic Glutamate Receptors in Primary Cultured Rat Osteoblasts recorded using PC501a Amplifier
18% Login to view WR01 PC501A Amplifier.pdf
[229 KB]
Expression of Functional Metabolic Glutamate Receptors in Primary Cultured Rat Osteoblasts recorded using PC501a Amplifier
17% Login to view MC02metabolic cage pump.pdf
[166 KB]
Respiration Metabolic Cage use in finding species differences in Pharmacokinetics of a Hepatoprotective agent
   

Back to Top



Manuals Back to Top

Displaying 1 to 4 of 4 results for Metabolic Monitoring System  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
70% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews