Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Electrophysiology Products NeuroLog System Rack and Power Supply for NeuroLog® System


Larger Views

 

Rack and Power Supply for NeuroLog® System
The NeuroLog module frame and power supply are housed in a fully finished, enclosed case. The case has handles and integral rack mounting hardware so that it can be shifted directly between rack and bench top. The case contains 13 module bays plus power supply panel.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
650283 NL900D Rack (Case) with Power Supply -- 10 days View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• High quality
• Dependable and efficient
• Innovative
• Modular — easy to install modules as you need them
• Flexible
• Fewer interface problems
• Less costly than general purpose instruments
• Built in logic circuit indicates excessive loading

The NeuroLog™ module frame and power supply are housed in a fully finished, enclosed case. The case has handles and integral rack mounting hardware so that it can be shifted directly between rack and bench top. The case contains 13 module bays plus power supply panel.
The NeuroLog™ case has an integral module retention system, consisting of a simple, slide action lever on the power supply panel. Therefore, fittings such as retained screws, D-locks, etc., on individual module front panels are unnecessary. This simple design enables easy, rapid, changes in module arrangements, and ultimately reduces the cost of the modules.
The NeuroLog™ power supply produces three voltages (+15 V, +5 V, and -15 V), stabilized against line and load variations. The voltage outputs are rated at 650 mA, 3.0A, and 650 mA, respectively. All three supplies have internal ‘fold-over’ current limiting; the 15V supplies, in addition, are protected with series fuses. Each supply has less than 15 mV line ripple at maximum load. The power supply transformer employs a sectionalized winding former for additional safety and complies with the requirements of IEC601 part 1 and BS5724. The power supply provides sufficient power for almost any mix of NeuroLog™ modules.
A unique feature of the NeuroLog™ power supply is a built-in logic circuit which indicates (by extinguishing the power supply indicator on the front panel) excessive loading of one or more of the three supply outputs. While it is expected that a power supply failure will never occur using NeuroLog™ modules, the fault indication is invaluable when testing custom circuits built in the NL50 Blank Module.


Specifications Back to Top

Specifications650283
Dimensions H x W x D English5.25 x 19 x 12.5 in without feet
Dimensions H x W x D Metric133 x 483 x 317 cm without feet
ModelNL900D
Weight (kg)5.5 kg without modules
Weight (lbs)12.1 lbs without modules

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 23 results for Rack and Power Supply for NeuroLog® System   Page 1  2  3 

Score

Document

Description

100% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
57% Login to view PDF10004.pdf
[48 KB]
Battery Powered Isotonic Transducer Manual
50% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
27% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
23% Login to view PI12 mri inject.pdf
[201 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery
20% Login to view PP69 PHD 2000 Syringe Pump.pdf
[598 KB]
Passive mixing in a three-dimensional serpentine microchannel - Microelectromechanical Systems, Journal of
20% Login to view PP41Infusion Pump.pdf
[496 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
20% Login to view Permeation and Activation of the M2 Ion Channel.PDF
[248 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
19% Login to view TD0160 1.PDF
[348 KB]
Isotomic Transducer use in Stabilization of Temporally Summated Muscle Contractions in the Lobster (Panulirus) Pyloric System
19% Login to view WR19FA 1.PDF
[220 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
   

Back to Top



Manuals Back to Top

Displaying 1 to 5 of 5 results for Rack and Power Supply for NeuroLog® System  

Score

Document

Description

100% Login to view 506378.pdf
[48 KB]
Battery Powered Isotonic Transducer Manual
86% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
74% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
71% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
61% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews