Home Microinjection Systems Nanoliter Injector Microinjection Systems


Larger Views

 

Nanoliter Injector Microinjection Systems
The Nanoject II is the latest development in the Nanoject family of microinjectors. One of the unique features of the Nanoject II is the use of a higher torque motor than in previous models. This new motor is smoother in operation resulting in substantially reduced tip movement. A new collect configuration holds the micropipette more securely thereby reducing air infiltration and oil leakage. The two-speed fill/inject mode will allow the user to fill and inject at half speed, facilitating the use of smaller micropipettes. The handling of more viscous samples will also be improved. All of the above factors enhance the precise delivery of sample.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
690130 Nanoject II Nanoliter Injector, 115 V, 60 Hz, US Plug -- 10 days View Pricing
Login to Shop
690131 Nanoject II Nanoliter Injector, 230 V, 50 Hz, European Plug -- 10 days View Pricing
Login to Shop
690132 Nanoject II Nanoliter Injector, 230 V, 50 Hz, UK Plug -- 10 days View Pricing
Login to Shop
690133 Replacement Glass for Nanoliter Injector, 88.9 x 1.14 x 0.053 mm (3.5 x 0.045 x 0.021 in) (L x OD x ID), Vial of 100 -- 10 days View Pricing
Login to Shop
690134 Replacement Glass for Nanoliter Injector, 177.8 x 1.14 x 0.053 mm (7 x 0.045 x 0.021 in) (L x OD x ID), Vial of 100 -- 10 days View Pricing
Login to Shop
690135 Replacement Flared Glass for Nanoliter Injector, 90 mm (3.5 in), Vial of 100 Yes -- View Pricing
Login to Shop
690137 Replacement Special Flared O-Ring for Nanoliter Injector -- 13 days View Pricing
Login to Shop
690138 Replacement Wire Plunger for Nanoliter Injector -- 13 days View Pricing
Login to Shop
690139 Replacement Needle for Nanoliter Injector, 30 ga x 51 mm (2 in) Yes -- View Pricing
Login to Shop
690140 Footswitch for Nanoliter Injector -- 10 days View Pricing
Login to Shop
690141 Support Base for Nanoliter Injector -- 10 days View Pricing
Login to Shop
690142 Universal Mounting Adapter for Nanoliter Injector Yes -- View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Lower volume (2.3 nl) capability
• Positive displacement technology
• 2.3 to 69.0 nl range of volumes
• Minimal vibration
• New improved high torque motor
• Membrane key pad
• Improved micropipette holder
• Two speed injection/fill rates
• Auto ‘Home’ capability

The Nanoject II is the latest development in the Nanoject family of microinjectors. One of the unique features of the Nanoject II is the use of a higher torque motor than in previous models. This new motor is smoother in operation resulting in substantially reduced tip movement. A new collect configuration holds the micropipette more securely thereby reducing air infiltration and oil leakage. The two-speed fill/inject mode will allow the user to fill and inject at half speed, facilitating the use of smaller micropipettes. The handling of more viscous samples will also be improved. All of the above factors enhance the precise delivery of sample.

Volumes for the Nanoject II range from 2.3 nl to 69 nl. Although previous models of the Nanoject series are excellent for Xenopus injections, the smaller tips and smaller injection volumes of the Nanoject II allow users to perform injections into other specimens/
applications that previously could not be performed.

Positive displacement technology and the use of precision micropipettes, eliminate the need for tedious calibration when the viscosity of the sample changes. Contaminants in the sample do not hinder or change the injection volume as with some other injectors. An optional universal mounting adapter provides easy mounting of the Nanoject II to a variety of micromanipulators and stereotaxic frames.


Specifications Back to Top

Specifications690130690131690132690133690134690135690137690138690139690140690141690142
CertificationsCECECE         
Change Inject SpeedDip switch #5Dip switch #5Dip switch #5         
Change VolumeDip switches #1 to #4Dip switches #1 to #4Dip switches #1 to #4         
Diameter English*na in*na in*na in*na in*na in*na in*na in*na in2 in*na in*na in*na in
Diameter Metric*na mm*na mm*na mm*na mm*na mm*na mm*na mm*na mm51 mm*na mm*na mm*na mm
Empty Speed Metric92 nl/sec92 nl/sec92 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
Fill Speed Fast Metric46 nl/sec46 nl/sec46 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
Fill Speed Slow Metric23 nl/sec23 nl/sec23 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
Gauge        30   
Glass ID English0.021 in0.021 in0.021 in0.021 in0.021 in*na in*na in*na in*na in*na in*na in*na in
Glass ID Metric0.053 mm0.053 mm0.053 mm0.053 mm0.053 mm*na mm*na mm*na mm*na mm*na mm*na mm*na mm
Glass Length English*na in*na in*na in3.5 in7 in3.5 in*na in*na in*na in*na in*na in*na in
Glass Length Metric*na mm*na mm*na mm88.9 mm177.8 mm90 mm*na mm*na mm*na mm*na mm*na mm*na mm
Glass OD English0.045 in0.045 in0.045 in0.045 in0.045 in*na in*na in*na in*na in*na in*na in*na in
Glass OD Metric1.14 mm1.14 mm1.14 mm1.14 mm1.14 mm*na mm*na mm*na mm*na mm*na mm*na mm*na mm
Glass PropertiesSoftening point 780°CSoftening point 780°CSoftening point 780°C         
Injection Speed Fast Metric46 nl/sec46 nl/sec46 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
Injection Speed Slow Metric23 nl/sec23 nl/sec23 nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec*na nl/sec
OperationAutomaticAutomaticAutomatic         
Power Consumption115 V, 60 Hz, US Plug230 V, 50 Hz, European Plug230 V, 50 Hz, UK Plug         
Volume Range Metric2.3 to 69.0 nl2.3 to 69.0 nl2.3 to 69.0 nl*na nl*na nl*na nl*na nl*na nl*na nl*na nl*na nl*na nl
Weight English3.5 oz3.5 oz3.5 oz*na oz*na oz*na oz*na oz*na oz*na oz*na oz*na oz*na oz
Weight Metric99.2 kg99.2 kg99.2 kg*na kg*na kg*na kg*na kg*na kg*na kg*na kg*na kg*na kg

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 21 results for Nanoliter Injector Microinjection Systems   Page 1  2  3 

Score

Document

Description

100% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
37% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
36% Login to view Zebrafish mitotic kinesin-like protein 1 functions in embryonic cytokinesis.pdf
[1.1 MB]
Zebrafish mitotic kinesin-like protein 1 (Mklp1) functions in embryonic cytokinesis
31% Login to view Regulate the Motor Output of Cochlear Outer Hair Cells.PDF
[504 KB]
Two Distinct Ca2+ - Dependent Signaling Pathways regulate the Motor Output of Cochlear Outer Hair Cells with Pneumatic Injection System
31% Login to view Action of 2,3-butanedione monoxime on capacitance.PDF
[352 KB]
Pneumatic Injection System use in finding Action of 2,3-butanedione monoxime on capacitance and electromotility of guinea-pig cochlear outer hair cells
21% Login to view Rapid Intermittent Movement of Axonal Neurofilaments.PDF
[743 KB]
Pressure Injector use in finding Rapid Intermittent Movement of Axonal Neurofilaments Observed by Fluorescene Photobleaching
20% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
20% Login to view PI01PL 1.PDF
[734 KB]
Pressure Injector use in finding Rapid Intermittent Movement of Axonal Neurofilaments Observed by Fluorescene Photobleaching
17% Login to view PI12 mri inject.pdf
[201 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery
16% Login to view PI02.pdf
[431 KB]
Pico-Injector use in Inhibition of the Inositol Trisphosphate Receptor of Mouse Eggs and A7r5 Cells
   

Back to Top



Manuals Back to Top

Displaying 1 to 7 of 7 results for Nanoliter Injector Microinjection Systems  

Score

Document

Description

100% Login to view 650001 Pico Injector PLI 100 Manual.pdf
[594 KB]
Model PLI-100 Pico-Injector User's Manual
100% Login to view 650004 Pico Injector PLI 90 Manual.pdf
[521 KB]
Model PLI-90 Pico-Injector User's Manual
60% Login to view PicoInjector PLI90.pdf
[110 KB]
Model PLI-90 Pico Injector Manual
60% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
58% Login to view AutoInjector NVI570.pdf
[35 KB]
Auto Injector Manual
53% Login to view PicoInjector PLI100.pdf
[949 KB]
Model PLI-100 Pico Injector Manual
51% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews