Home Microinjection Systems Pressure Injection Systems


Larger Views

 

Pressure Injection Systems
The PM-4 and PM-8 programmable 4 and 8-Channel Pressure Injector systems are designed for one to eight channel intracellular injection and extracellular perfusion. These microinjection and perfusion engines are especially designed for pharmacological drug testing, molecular biological DNA, RNA transferring, intracytoplasmic sperm injection and cell electrophysiological applications.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
690152 Model PM4 4-Channel Pressure Injection System -- 10 days View Pricing
Login to Shop
690153 Model PM8 8-Channel Pressure Injection System -- 10 days View Pricing
Login to Shop
690164 PP-4 Pulled 4-Barrel Pipette -- 10 days View Pricing
Login to Shop
690163 PP-7 Pulled 7-Barrel Pipette Yes -- View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Multiple function system for micro-injection and perfusion
• Up to 8 injection/perfusion outputs, one hold cell output and one synchronized drain out channel
• Programmable timers, counters and step sequences which can be stored for reuse
• Manual control or automatic sequential step cycle operation
• Front panel display for pressures and programming information

The PM-4 and PM-8 programmable 4 and 8-Channel Pressure Injector systems are designed for one to eight channel intracellular injection and extracellular perfusion. These microinjection and perfusion engines are especially designed for pharmacological drug testing, molecular biological DNA, RNA transferring, intracytoplasmic sperm injection and cell electrophysiological applications.

Combining an advanced micro-controller with precision pneumatic components, these systems can simultaneously control up to eight injection micropipettes or eight perfusion vials and one cell holding pipette and one drain pipette. The four (PM-4) or eight (PM-8) injection/perfusion output ports can be controlled separately or combined together to perform actions such as injection, capillary action balancing, suction or clear up. The cell holding output port can produce an adjusted gentle suction to hold a cell, eject a pressure to push a cell, or completely clear the holding pipette. Another drain output port can simultaneously produce an adjusted suction to drain and clear out liquid before the next channel micro-perfusion. The PM-4/8 can deliver different quantity agents and drugs from picoliters to continuous perfusion. All output pressures and vacuums can be regulated and can be displayed real-time on the front panel display. Previous pressure readings can also be recovered on the display for setting comparison.

Besides programmable timers and counters, there are 16 programmable and savable injection/perfusion sequences with 32 programmable steps in each sequence. Each sequence can be repeated continuously or triggered manually. The interval time between steps can be programmed for automatic sequential cycle or manual trigger. There are two foot switch connectors for sequential step trigger and injection trigger. A digital remote port can be connected to an optional remote key pad or be controlled by a computer. With exceptional versatility and extremely precise control, either the PM-4 or 8 is an ideal multi-channel injection/perfusion engine. Below are the components supplied with each of the Pressure Injection Systems.

Pressure Injection System 69-0152 or 69-0153
Cat. No. Product
69-0154 IP1 Input Tubing with Connector Qty: 1 or 1
69-0156 OP2 Output Tubing with Connector Only Qty: 6 or 10
69-0157 FSW Foot Switch Qty: 1
69-0164 PP-4 Pulled 4-Barrel Pipette Qty: 1 or 0
69-0166 HOLD4 Holder for 4-Barrel Pipette Qty: 1 or 0
69-0163 PP-7 Pulled 7-Barrel Pipette Qty: 1 or 0
69-0167 HOLD7 Holder for 7-Barrel Pipette Qty: 1 or 0
- Power Cord Qty: 1 or 1
- User’s Manual Qty: 1 or 1


Specifications Back to Top

Specifications690152690153690164690163
Balance Pressure English0.05 to 10 p.s.i. (regulated)0.05 to 10 p.s.i. (regulated)*na p.s.i. (regulated)*na p.s.i. (regulated)
CertificationsCECE  
Clear Hold Pressure English0 to 3 p.s.i. (regulated)0 to 3 p.s.i. (regulated)*na p.s.i. (regulated)*na p.s.i. (regulated)
Clearing Pressure English30 to 100 p.s.i.30 to 100 p.s.i.*na p.s.i.*na p.s.i.
Counter Setting Range1 to 2551 to 255  
Display Accuracy±0.05 p.s.i. for pressure, ±0.2 in for vacuum (< 2 in H2O)±0.05 p.s.i. for pressure, ±0.2 in for vacuum (< 2 in H2O)  
Drain Vacuum0 to 30 in of water (regulated)0 to 30 in of water (regulated)*na in of water (regulated)*na in of water (regulated)
Fill Vacuum English0 to 24 inHg (regulated)0 to 24 inHg (regulated)*na inHg (regulated)*na inHg (regulated)
Hold Vacuum Metric0 to 30 in of water (regulated)0 to 30 in of water (regulated)*na in of water (regulated)*na in of water (regulated)
Injection Pressure English0.05 to 60 p.s.i. (regulated)0.05 to 60 p.s.i. (regulated)*na p.s.i. (regulated)*na p.s.i. (regulated)
Input Gas Pressure English30 to 100 p.s.i.30 to 100 p.s.i.*na p.s.i.*na p.s.i.
ModelPM4PM8PP-4PP-7
Output ChannelsFour (PM-4) or eight (PM-8) injection / perfusion outputs, one synchronized drain out and one cell hold channelFour (PM-4) or eight (PM-8) injection / perfusion outputs, one synchronized drain out and one cell hold channel  
Power Consumption100, 120 or 220 VAC, 35 W100, 120 or 220 VAC, 35 W  
Programmable Steps32 steps for each sequence32 steps for each sequence  
Remote Control PortsDB9 connector for remote key pad, foot switch jack and BNC for negative TTL trigger, jack connector for injection foot switchDB9 connector for remote key pad, foot switch jack and BNC for negative TTL trigger, jack connector for injection foot switch  
Repeatability±0.02 p.s.i. p.s.i.±0.02 p.s.i. p.s.i.*na p.s.i.*na p.s.i.
Savable Sequences16 sequences16 sequences  
Signal Output PortsEight BNCs for injection signal on output port 1 to 4Eight BNCs for injection signal on output port 1 to 4  
Timer Setting Range10 msec to 327.67 sec (10 msec resolution for whole range)10 msec to 327.67 sec (10 msec resolution for whole range)  

Back to Top



Journal Articles Back to Top

Displaying 1 to 10 of 29 results for Pressure Injection Systems   Page 1  2  3 

Score

Document

Description

100% Login to view HS08 pressure transducer.pdf
[46 KB]
Pressure Transducer use in finding blood pressure and heart rate spectral changes
87% Login to view Interleukin-12-mediated induction of systemic immunity.pdf
[213 KB]
Interleukin-12-mediated induction of systemic immunity in the perihpery and recruitment of activated T cells into the brain produce limited antitumor effects compared with interleukin-2
77% Login to view WR04PL 1.PDF
[495 KB]
Two Distinct Ca2+ - Dependent Signaling Pathways regulate the Motor Output of Cochlear Outer Hair Cells with Pneumatic Injection System
72% Login to view VT13 Air-sac pressures in little penguins.pdf
[142 KB]
Air-sac pressures in little penguins
68% Login to view Action of 2,3-butanedione monoxime on capacitance.PDF
[352 KB]
Pneumatic Injection System use in finding Action of 2,3-butanedione monoxime on capacitance and electromotility of guinea-pig cochlear outer hair cells
68% Login to view WR03PL 1.PDF
[344 KB]
Pneumatic Injection System use in finding Action of 2,3-butanedione monoxime on capacitance and electromotility of guinea-pig cochlear outer hair cells
68% Login to view Regulate the Motor Output of Cochlear Outer Hair Cells.PDF
[504 KB]
Two Distinct Ca2+ - Dependent Signaling Pathways regulate the Motor Output of Cochlear Outer Hair Cells with Pneumatic Injection System
55% Login to view PP86.pdf
[180 KB]
Dexenfluramine-Induced Systemic Vasoconstriction
55% Login to view VT06 Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation.pdf
[200 KB]
h4Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation010100051p
44% Login to view PP41 y2-Melanocyte-Stimulating Hormone Suppression of Systemic Inflammatory Responses to Endotoxin.pdf
[495 KB]
Melanocyte-stimulating hormone suppression of systemic inflammatory responses
   

Back to Top



Manuals Back to Top

Displaying 1 to 8 of 8 results for Pressure Injection Systems  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
90% Login to view Model708 557081.pdf
[43 KB]
Harvard 708 Pressure Controlled Ventilator Manual
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
82% Login to view 603002 603003.pdf
[77 KB]
Research Grade Blood Pressure Transducer Manual
73% Login to view 724488 724489.pdf
[124 KB]
Research Grade Blood Pressure Transducer Manual
70% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
66% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews