Welcome to Harvard Apparatus! — Login / Register
Search

Search for these keywords
Home Catalogs Online Technical Resources
Shopping Cart Shopping
   Cart
                     My Account
Advanced Search   
Products by Category

Featured Products
Warner Cell Electrophysiology & Cell Biology Research
Hugo Sachs Elektronic Isolated Organ and Tissue Systems
BTX Electroporation and Electrofusion Products
Panlab Behavior Research Products
Hoefer Electrophoresis Products
Clark Glass Products
Navicyte Ussing/Diffusion Chambers
Harvard Apparatus

GoDaddy
 

Home Microinjection Systems Pressure Injection Systems
 


Larger Views

Pressure Injection Systems
The PM-4 and PM-8 programmable 4 and 8-Channel Pressure Injector systems are designed for one to eight channel intracellular injection and extracellular perfusion. These microinjection and perfusion engines are especially designed for pharmacological drug testing, molecular biological DNA, RNA transferring, intracytoplasmic sperm injection and cell electrophysiological applications.
Search for Product in current catalog
Item Listing Full Description Specifications Journal Articles Manuals
Item# Description In Stock Lead Time U.S. List Price Quantity
690152 Model PM4 4-Channel Pressure Injection System -- 10 days View Pricing
Login to Shop
690153 Model PM8 8-Channel Pressure Injection System -- 10 days View Pricing
Login to Shop
690164 PP-4 Pulled 4-Barrel Pipette -- 10 days View Pricing
Login to Shop
690163 PP-7 Pulled 7-Barrel Pipette Yes -- View Pricing
Login to Shop

For local pricing, contact your nearest distributor.



Full Description Back to Top

• Multiple function system for micro-injection and perfusion
• Up to 8 injection/perfusion outputs, one hold cell output and one synchronized drain out channel
• Programmable timers, counters and step sequences which can be stored for reuse
• Manual control or automatic sequential step cycle operation
• Front panel display for pressures and programming information

The PM-4 and PM-8 programmable 4 and 8-Channel Pressure Injector systems are designed for one to eight channel intracellular injection and extracellular perfusion. These microinjection and perfusion engines are especially designed for pharmacological drug testing, molecular biological DNA, RNA transferring, intracytoplasmic sperm injection and cell electrophysiological applications.

Combining an advanced micro-controller with precision pneumatic components, these systems can simultaneously control up to eight injection micropipettes or eight perfusion vials and one cell holding pipette and one drain pipette. The four (PM-4) or eight (PM-8) injection/perfusion output ports can be controlled separately or combined together to perform actions such as injection, capillary action balancing, suction or clear up. The cell holding output port can produce an adjusted gentle suction to hold a cell, eject a pressure to push a cell, or completely clear the holding pipette. Another drain output port can simultaneously produce an adjusted suction to drain and clear out liquid before the next channel micro-perfusion. The PM-4/8 can deliver different quantity agents and drugs from picoliters to continuous perfusion. All output pressures and vacuums can be regulated and can be displayed real-time on the front panel display. Previous pressure readings can also be recovered on the display for setting comparison.

Besides programmable timers and counters, there are 16 programmable and savable injection/perfusion sequences with 32 programmable steps in each sequence. Each sequence can be repeated continuously or triggered manually. The interval time between steps can be programmed for automatic sequential cycle or manual trigger. There are two foot switch connectors for sequential step trigger and injection trigger. A digital remote port can be connected to an optional remote key pad or be controlled by a computer. With exceptional versatility and extremely precise control, either the PM-4 or 8 is an ideal multi-channel injection/perfusion engine. Below are the components supplied with each of the Pressure Injection Systems.

Pressure Injection System 69-0152 or 69-0153
Cat. No. Product
69-0154 IP1 Input Tubing with Connector Qty: 1 or 1
69-0156 OP2 Output Tubing with Connector Only Qty: 6 or 10
69-0157 FSW Foot Switch Qty: 1
69-0164 PP-4 Pulled 4-Barrel Pipette Qty: 1 or 0
69-0166 HOLD4 Holder for 4-Barrel Pipette Qty: 1 or 0
69-0163 PP-7 Pulled 7-Barrel Pipette Qty: 1 or 0
69-0167 HOLD7 Holder for 7-Barrel Pipette Qty: 1 or 0
- Power Cord Qty: 1 or 1
- User’s Manual Qty: 1 or 1


Specifications Back to Top

Specifications690152690153690164690163
Balance Pressure English0.05 to 10 p.s.i. (regulated)0.05 to 10 p.s.i. (regulated)*na p.s.i. (regulated)*na p.s.i. (regulated)
CertificationsCECE  
Clear Hold Pressure English0 to 3 p.s.i. (regulated)0 to 3 p.s.i. (regulated)*na p.s.i. (regulated)*na p.s.i. (regulated)
Clearing Pressure English30 to 100 p.s.i.30 to 100 p.s.i.*na p.s.i.*na p.s.i.
Counter Setting Range1 to 2551 to 255  
Display Accuracy±0.05 p.s.i. for pressure, ±0.2 in for vacuum (< 2 in H2O)±0.05 p.s.i. for pressure, ±0.2 in for vacuum (< 2 in H2O)  
Drain Vacuum0 to 30 in of water (regulated)0 to 30 in of water (regulated)*na in of water (regulated)*na in of water (regulated)
Fill Vacuum English0 to 24 inHg (regulated)0 to 24 inHg (regulated)*na inHg (regulated)*na inHg (regulated)
Hold Vacuum Metric0 to 30 in of water (regulated)0 to 30 in of water (regulated)*na in of water (regulated)*na in of water (regulated)
Injection Pressure English0.05 to 60 p.s.i. (regulated)0.05 to 60 p.s.i. (regulated)*na p.s.i. (regulated)*na p.s.i. (regulated)
Input Gas Pressure English30 to 100 p.s.i.30 to 100 p.s.i.*na p.s.i.*na p.s.i.
ModelPM4PM8PP-4PP-7
Output ChannelsFour (PM-4) or eight (PM-8) injection / perfusion outputs, one synchronized drain out and one cell hold channelFour (PM-4) or eight (PM-8) injection / perfusion outputs, one synchronized drain out and one cell hold channel  
Power Consumption100, 120 or 220 VAC, 35 W100, 120 or 220 VAC, 35 W  
Programmable Steps32 steps for each sequence32 steps for each sequence  
Remote Control PortsDB9 connector for remote key pad, foot switch jack and BNC for negative TTL trigger, jack connector for injection foot switchDB9 connector for remote key pad, foot switch jack and BNC for negative TTL trigger, jack connector for injection foot switch  
Repeatability±0.02 p.s.i. p.s.i.±0.02 p.s.i. p.s.i.*na p.s.i.*na p.s.i.
Savable Sequences16 sequences16 sequences  
Signal Output PortsEight BNCs for injection signal on output port 1 to 4Eight BNCs for injection signal on output port 1 to 4  
Timer Setting Range10 msec to 327.67 sec (10 msec resolution for whole range)10 msec to 327.67 sec (10 msec resolution for whole range)  

Back to Top



Journal Articles Back to Top

Displaying 21 to 29 of 29 results for Pressure Injection Systems   Page 1  2  3 

Score

Document

Description

17% Login to view Permeation and Activation of the M2 Ion Channel.PDF
[248 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
17% Login to view VT06 683 load.pdf
[218 KB]
Animal Ventilator use in finding load as an acute determinant of end-diastolic pressure-volume relation
16% Login to view WR19FA 1.PDF
[220 KB]
Permeation and Activation of the M2 Ion Channel of Influenza A Virus with use of Fast Step Perfusion System
16% Login to view TD0160 1.PDF
[348 KB]
Isotomic Transducer use in Stabilization of Temporally Summated Muscle Contractions in the Lobster (Panulirus) Pyloric System
16% Login to view VT25 Ventilator.pdf
[147 KB]
MiniVent use in finding Evidence for Synergy Between Adrenergic and Nonadrenergic Mechanisms in Central Blood Pressure Regulation
15% Login to view PP33PR 1.PDF
[393 KB]
Micro/nano spacecraft thermal control using a MEMS-based pumped liquid cooling system with use of Programmable syringe pump
15% Login to view HS12P2 Effects of GYK!-16638 in rabbits.pdf
[236 KB]
PII: S0014-2999(00)00591-4
13% Login to view HS04 latex balloon.pdf
[76 KB]
Latex Balloon use in finding Benefical Effect of Glucose on Short-Term, Perfusion-Pressure Induced Changes of Contractile Efficiency in Isolated Rabbit Hearts
12% Login to view HS04 Contractile Efficiency in Hibernating Myocardium.pdf
[79 KB]
Latex Balloon use in finding Benefical Effect of Glucose on Short-Term, Perfusion-Pressure Induced Changes of Contractile Efficiency in Isolated Rabbit Hearts
   

Back to Top



Manuals Back to Top

Displaying 1 to 8 of 8 results for Pressure Injection Systems  

Score

Document

Description

100% Login to view metric system trivia.pdf
[146 KB]
Microsoft Word - Lesson1.doc
90% Login to view Model708 557081.pdf
[43 KB]
Harvard 708 Pressure Controlled Ventilator Manual
86% Login to view Perfusion Tissue Systems Guide.pdf
[105 KB]
New BS4_K_Isolated Organ.qxd
82% Login to view 650073 76 Brain Slice Chmbr Manual.pdf
[706 KB]
Brain Slice Chamber System User's Manual
82% Login to view 603002 603003.pdf
[77 KB]
Research Grade Blood Pressure Transducer Manual
73% Login to view 724488 724489.pdf
[124 KB]
Research Grade Blood Pressure Transducer Manual
70% Login to view 650073-0076 Manual.pdf
[285 KB]
Brain Slice Chamber System Manual
66% Login to view Nanoleader Pump Series NLS110P Pressure Pump Manual.pdf
[2.2 MB]
705000 NLS110P Pump Manual
   

Back to Top



  Privacy Policy   |   Terms and Conditions   |   Site Map
Copyright©2004 Harvard Apparatus - All rights reserved.
1-800-272-2775   1-508-893-8999
Website-related comments or concerns can be emailed to our webmaster.

Anesthesia Equipment Animal Handling Products Behavior Research Products Biological Measurement Products Cardiovascular Products Cell Biology Products CPK® Atomic Models Delivery & Sampling Products Dialysis / Sample Prep / SPE Electrophysiology Products Electroporation / Transfection General Laboratory Products Homeothermic/Temperature Control Isolated Organ & Isolated Tissue Microincubation / Microinjectors Molecular Biology Products Neuroscience Products Non-Invasive Blood Pressure Physiology Products Respiratory Products Stereotaxic Instruments Surgical Equipment Surgical Instruments Syringe Pumps/Peristaltic Pumps Tubing & Connectors Ventilators Application Specific Product Overviews