Volume Calibrated Syringes

Volume Calibrated Syringes

These syringes provide easy, accurate duplications of fixed volumes. Each Syringe is serialized and traceable to the National Institute of Standards and is calibrated against ASTM E542-85.

• Accurate to ±1% of reading

Item# Description U.S. List Price Quantity
59-9390 10 ml Volume Calibrated Syringe with 2 ml Volume Stop Minimum Gradiation - 15 x 10.5 mm (OD x ID) adapters
59-9653 10 ml Volume Calibrated Syringe with 2 ml Volume Stop Minimum Gradiation - 22 x 15 mm (OD x ID) adapters
59-9391 100 ml Volume Calibrated Syringe with 20 ml Volume Stop Minimum Gradiation - 15 x 10.5 mm (OD x ID) adapters
59-9654 100 ml Volume Calibrated Syringe with 20 ml Volume Stop Minimum Gradiation - 22 x 15 mm (OD x ID) adapters
59-9655 500 ml Volume Calibrated Syringe with 50 ml Volume Stop Minimum Gradiation - 22 x 15 mm (OD x ID) adapters
59-9656 500 ml Volume Calibrated Syringe with 50 ml Volume Stop Minimum Gradiation - 28.6 x 22 mm (OD x ID) adapters
59-9392 500 ml Volume Calibrated Syringe with 50 ml Volume Stop Minimum Gradiation - 35 x 28.6 mm (OD x ID) adapters
59-9645 1 L Volume Calibrated Syringe with 50 ml Volume Stop Minimum Gradiation - 22 x 15 mm (OD x ID) adapters
59-9646 1 L Volume Calibrated Syringe with 50 ml Volume Stop Minimum Gradiation - 28.6 x 22 mm (OD x ID) adapters
59-9644 1 L Volume Calibrated Syringe with 50 ml Volume Stop Minimum Gradiation - 35 x 28.6 mm (OD x ID) adapters
Login for U.S. Pricing

These syringes provide easy, accurate duplications of fixed volumes. Each Syringe is serialized and traceable to the National Institute of Standards and is calibrated against ASTM E542-85. <p><p>&bull; Accurate to ±1% of reading

The 10 ml and 100 ml Syringes are made from acrylic plastic. The volume stops are located on the graduated piston rod and are engaged with a spring-loaded detent. A screw is tightened with a socket-hex wrench (supplied) to secure the volume stop.

The larger 500 ml and 1 liter Syringes have anodized aluminum cylinders. The volume stops are located on the graduated piston rod and are tightened with a socket-hex wrench (supplied). For each Syringe these stops are set at predetermined minimum graduations throughout the full range of the Syringe volume. They provide easy, accurate duplications of fixed volumes.

Each Syringe is serialized and traceable to the National Institute of Standards and is calibrated against ASTM E542-85. It is important to select the Syringe with the appropriate outlet port adapter to fit specific applications. Outlet port adapters with an OD or ID of 10.5, 15 or 22 mm are standard medical tapers. All other sizes are straight connectors.

Specifications59-939059-965359-939159-965459-965559-965659-939259-964559-964659-9644
Outlet Port Adapter OD x ID15 x 10.5 mm22 x 15 mm15 x 10.5 mm22 x 15 mm22 x 15 mm28.6 x 22 mm35 x 28.6 mm22 x 15 mm28.6 x 22 mm35 x 28.6 mm
Syringe Size10 ml10 ml100 ml100 ml500 ml500 ml500 ml1 L1 L1 L
Volume Stop Minimum Graduation2 ml2 ml20 ml20 ml50 ml50 ml50 ml50 ml50 ml50 ml