UP-100IH CORE SYSTEM, BASIC, 115V 73-4384

UP-100IH CORE SYSTEM, BASIC, 115V 73-4384

UP-100IH CORE SYSTEM, BASIC, 115V 73-4384 If your chosen options require more than 10 Slot Units you will need to choose the UP-100IH Advanced system For a working unit, the core system requires the addition of a selection of one of the options UP-MOUSE or UP-RAT/GP.

Item# Description U.S. List Price Quantity
73-2070 HEART CHAMBER TO UP-100 SYSTEM (SIZE 3 RODENTS) INCL. HOLDER
73-0720 PARTS FOR ADAPTATION OF THE UP-100 FOR RETROGRADE LANGENDORFF HEART PERFUSION
73-2802 THERMOSTATIC CIRCULATOR E 103, BATH VOLUME 3 L, 115 V/60 Hz
73-2952 ISM 829/115V ROLLER PUMP REGLO ANALOGUE, 2 CHANNELS, 0.005 - 49.4 ML/MIN
73-2068 WINDKESSEL FOR ABSORPTION OF PULSATION CAUSED BY ROLLER PUMP
73-1521 PLUGSYS Case, Type 601
73-3862 APT300 Pressure Transducer for PLUGSYS Module
73-1793 Transducer Amplifier Module (TAM-D)
73-3869 Holder for APT300 Transducer, 8 mm Rod, Length 75 mm
73-0566 Plexiglass Block Clamp - for mounting 73-4337 Bar onto Lab Stand
73-0065 Transducer Amplifier Module (TAM-A)
Login for U.S. Pricing
UP-100IH CORE SYSTEM, BASIC, 115V 73-4384 The UP-100IH is the preferred system for compound screening that requires the basic measured parameters such as simple Left Ventricular Pressure (IsovolumetricLVP), ECG Lead II measurements, and temperature.Therefore the more common configuration of this system will be the UP-100IH Basic which allows the researcher to measure 2-3 parameters in addition to those that are included in the standard system (Aortic Pressure and LVP). Most researchers will also want to operate in a constant pressure perfusion mode and measure coronary flow, which is a simple addition to the basic system. The UP-100IH Advanced system allows up to the full range of available measured parameters beyond the basic system including direct coronary flow, ECG lead II, temperature measurement, and metabolic parameters (pH, pO2, pCO2). All UP-100IH systems can be used for constant pressure or constant flow perfusion of isolated hearts of mice, guineapigs, rats and newborn rabbits as long as the coronary flow is below 50 ml/min. Constant pressure perfusion is achieved by the optional addition of a controller (SCP) which modulates the flow generated by the perfusion pumpbased on a perfusion pressure feedback loop. The controller also provides an accurate, low-cost way to indirectly measure coronary flow. The system can be adapted for direct, real-time coronary flow measurement allowing the study of myogene autoregulation (reactive hyperemia) if required. Whether you are isolating cardiomyocytes following a physiology experiment or require occasional cardiomyocyte isolation in addition to the standard Langendorff assays, the Cell Isolation option to the UP-100IH will satisfy your requirements. Other useful add-ons include drug addition using a syringe pump and pacing. If perfusate containing albumin or erythrocytes is used, the oxygenation can be optimized with the addition of a fiber oxygenator. The complete system includes virtually everything you need to accomplish the basic Langendorff experiment, only requiring the addition of the appropriate species-specific package and the desired data acquisition system. Contact our expert technical team if you need assistance with system configuration, application support or custom design requests. If your chosen options require more than 10 Slot Units you will need to choose the UP-100IH Advanced system For a working unit, the core system requires the addition of a selection of one of the options UP-MOUSE or UP-RAT/GP.
Specifications73-295273-152173-179373-0065
Analog IndicationSpeed Control 0 - 5 V or 0 - 10 V and 0 - 20 mA respectivelyLine Cable, Screw driver for fitting Function Modules, Document Folder for Operating Instructions of Function Modules, 3 x BNC-BNC Output linesTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED display
Bridge Balance1.0 bar (14.5 PSI)5.9 x 9.25 x 16.5 inThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)Through 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)
Bridge Supply Voltage5.6 x 3.9 x 7 in150 x 235 x 420 mm+5V / 50 mA max.+5V / 50 mA max.
Electrical Calibration143 x 100 x 178 mmMetallic housing, gray plastic coated with pivoting feetSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
Selectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
GainRotation direction, Start/Stop10 slot units max.Selectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn TrimmerSelectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn Trimmer
Output Low-Pass Filter115 V / 50 Hz or 230 V / 50 Hz85 to 264 VAC (40 Watts), output voltage +5 VDC (5 A) and a) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
a) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
PLUGSYS Width*57 ml/min3-pin IEC mains with fuse and mains switch on back of housing2 slot units2 slot units
Power Supply0.002 ml/min10.6 lbs without PLUGSYS modules+5V through connector from PLUGSYS bus system+5V through connector from PLUGSYS bus system
Signal Output24.8 kg without PLUGSYS modulesa) On front panel through BNC socket a) On front panel through BNC socket
Transducer Input86-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?6-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?
20 W
IP 30
yes
MS-2/8-160
1.6 to 160 rpm
Adjustable in 1% steps (0-99%)
3 to 99%, resolution 1%, 2 digit potentiometer
7-8 m
MS/CA Click 'n' Go - Cassettes are included
115 VAC
2.0 kg
4.4 lbs