T Type Pod Accessories

T Type Pod Accessories

The T-type Pod is suitable for biological temperature measurements with 0.2 °C accuracy (dependent on temperature range). The unit is a compact signal conditioner for use with thermocouples to measure physiological temperatures. The T-type Pod accepts direct connection of T-type thermocouples fitted with miniature flat pin connectors. The output of the Pod is 10 mV/°C in the range 0 to 50 °C.

Item# Description U.S. List Price Quantity
77-0077 Rectal Thermocouple Probe for Mice, Model MLT1404
77-0076 Rectal Thermocouple Probe for Rats, Model MLT1403
77-0079 Rectal Thermocouple Probe for Large Animals, Model MLT1407
77-0074 T-Type Implantable Thermocouple Probe, 18 ga, Model MLT1401
77-0073 General Purpose Thermocouple Probe, Model MLT1400
77-0075 T-Type Ultra Fast Thermocouple Probe, Model MLT1402
77-0078 Needle Microbe Thermocouple Probe, Model MLT1406
Login for U.S. Pricing

The T-type Pod is suitable for biological temperature measurements with 0.2 °C accuracy (dependent on temperature range). The unit is a compact signal conditioner for use with thermocouples to measure physiological temperatures. The T-type Pod accepts direct connection of T-type thermocouples fitted with miniature flat pin connectors. The output of the Pod is 10 mV/°C in the range 0 to 50 °C.


Transducer Capability:

Any T-type thermocouple fitted with a miniature thermocouple connector is suitable for use with the T-type Pod.

For use with:

• MLT1403 Rectal Probe for Rats

• MLT1404 Rectal Probe for Mice

• MLT1407 Large Animal Rectal Probe

• MLT1400 General Purpose Thermocouple Probe

• MLT1401 T-type Implantable Thermocouple Probe

• MLT1405 T-type Implantable Thermocouple Probe

• MLT1402 T-type Ultra Fast Thermocouple Probe

• MLT1406 Needle Microbe Thermocouple

System Compatibility:

The T-type Pod connects to any PowerLab hardware units with Pod ports (8-pin DIN inputs). PowerLab and MacLab (except 4s, 8s and 16s) units without Pod ports can require the FE305 Pod Expander.

The T-type Pod is supported by the following versions of LabChart and Scope software:

WINDOWS LabChart v3.4.8 or later, MACINTOSH LabChart v3.6.3 or later

Theory of Operation:

The thermocouple voltage signal is amplified to produce 10 mV/°C at 25°C. Ice Point Reference compensation is provided by the direct measurement of the input connector temperature. The equivalent voltage is subtracted from the thermocouple voltage to compensate for the changes in the ambient temperature. Temperature changes are typically slow and filtering is provided by a 2 pole 10 Hz Butterworth filter. This will provide adequate filtering from mains power supply and allow fast temperature transients to be monitored.

Note: The output of the Pod is not linearized.

Stacking and Unstacking Pods:

Pods stack by clicking into place on top of each other. To separate stacked Pods, push the top Pod towards the back and then pull them apart from the back.
Specifications77-007777-007677-007977-007477-007377-007577-0078
Amplification Input AmplifierSee product page for complete specificationsSee product page for complete specificationsSee product page for complete specificationsSee product page for complete specificationsSee product page for complete specificationsSee product page for complete specificationsSee product page for complete specifications
Ball Tip Diameter Metric0.07 in0.13 in0.156 inT-Type5 ftT-Type29 gauge
Cable Length English1.7 mm3.2 mm4.0 mmMLT14011.5 mMLT14025 ft
Cable Length Metric5 ft5 ft5 ft-273 to 150°CT-Type-273 to 150°C1.5 m
Connector1.5 m1.5 m1.5 m1MLT14001T-Type
ModelT-TypeT-TypeT-TypeIsolated-273 to 400°CIsolatedMLT1406
Operating ConditionsMLT1404MLT1403MLT1407Data Acquisition1Data Acquisition-273 to 200°C
Package-273 to 125°C-273 to 125°CMax Temp 90°CType T ThermocoupleNon-isolatedType T Thermocouple1
Probe Type111±0.1 °CData Acquisition±0.1 °CNon-isolated
Product FamilyNon-isolatedNon-isolatedIsolated0.1 secType T Thermocouple0.005 secData Acquisition
Sensor ElementData AcquisitionData AcquisitionData Acquisition6.1 g0.06 in5.6 gType T Thermocouple
Shaft Diameter EnglishType T ThermocoupleType T ThermocoupleType T ThermocoupleTeflon™1.5 mmTwisted Pair0.39 in
Shaft Diameter Metric0.03 in0.06 in0.094 in0.03 in3 in0.01 in10 mm
Shaft Length English0.7 mm1.5 mm2.3 mm0.64 mm75 mm0.22 mm0.39 in
Shaft Length Metric0.8 in1 in0.25 in3.3 ft±0.1 °C3.3 ft10 mm
Temperature Accuracy19 mm25.4 mm6.4 mm1 m0.5 sec1 m±0.1 °C
Thermal Response Time±0.1 °C±0.1 °C±0.1 °C26 g0.125 sec
0.5 sec0.8 sec0.5 sec