Sterile Single Use Wide Range Pressure Sensors

Sterile Single Use Wide Range Pressure Sensors

Small-scale in-line sterile pressure sensors suitable for a variety of applications, i.e. in vivo, ex vivo, in situ and regenerative organ and cellular applications.

Item# Description U.S. List Price Quantity
88-0360 Sterile Pressure Sensor, pkg. of 10
88-0361 1⁄4 x 1⁄4-in Barbed Straight Connector with Female Luer Port, polycarbonate, pkg. of 10
88-0362 3⁄8 x 3⁄8-in Barbed Straight Connector with Female Luer Port, polycarbonate, pkg. of 10
88-0363 1⁄2 x 1⁄2-in Barbed Straight Connector with Female Luer Port, polycarbonate, pkg. of 10
88-0364 Luer Polysulphone 3-way Stopcock, pkg. of 10
88-0365 Reusable Shielded Cable, 12 ft, Unterminated, Colored Leads, Connector for Amplifier required
88-0366 Interface Cable for use with Sterile Pressure Sensors (88-0360); Connects to up to 4 transducers to ORCA Bioreactor Controller
88-0367 Interface Cable for use with Sterile Pressure Sensors (88-0360); Connects to Hugo Sachs PLUGSYS TAM Amplifier Modules
88-0368 Interface Cable for use with Sterile Pressure Sensors (88-0360); Connects to ADInstruments Bridge Amp
88-0369 Interface Cable for use with Sterile Pressure Sensors (88-0360); Connects to Harvard Apparatus Transducer Amplifier Interface
73-4479 Manual Pressure Calibrator, Range 0-300 mmHg
Login for U.S. Pricing

These are small-scale in-line sterile pressure sensors suitable for a variety of applications, i.e. in vivo, ex vivo, in situ and regenerative organ and cellular applications. 

  • Male/Female Luer lock with port cover for female Luer lock end for dead-end applications
  • In-line pressure transducers for low flow rates when used with 1⁄8-in or 1⁄16-in barbed connectors
  • May be paired with adapter Tee-connectors, 1⁄4-in or 3⁄8-in barbed connectors, for non-in-line applications
Specifications
Accuracy Better than ±2% of reading in the range of
0 to 6 psi (0 to 0.41 bar or 0 to 310 mmHg)
  Better than ±3% of reading in the range of
6 to 30 psi (0.41 to 2.07 bar)
  In range of 30 to 60 psi (2.07 to 4.14 bar)
typically better than ±5% of reading
Pressure Range -7 to +75 psi (-0.48 to +5.2 bar)
Biocompatibility All materials in contact with product fluid path
meet USP Class VI requirements
Manufacturing Environment  FDA Registered ISO 13485-certified facility;
Class 100,000 clean room
Gamma Irradiation Up to 50 kGy
Operating Temperature 15 to 40°C (other ranges with process qualification)
Storage Temperature -25° to 65°C
Input/Output Impedence 270 to 4,000 Ω
Excitation Voltage 2.5 to 10 VDC
Sensor Output 0.2584 mV/psi/Volt
Connector Custom molded water-tight 4 pin connector;
signal ± and excitation ±