StageTop Temperature and Humidity Control

StageTop Temperature and Humidity Control

Temperature and humidity control for the Bold Line StageTop Incubator

  • Accuracy on specimen temperature 0.1°C
  • Internal resolution 0.01°C
  • Set point value from room Temperature to 50°C
  • Can operate in sample or chamber feedback mode
  • Intuitive Touch Screen Display
  • Web operation through Smart Box
  • SDK available for integration in third party software
  • Connects to other modules through quick connector bus
  • Self calibration routine

We are the Authorized Distributor for Okolab products in the US.

Item# Description U.S. List Price Quantity
64-2201 (H301-T-UNIT-BL-PLUS) Thermal controller, operates in both chamber and specimen feedback
64-2011 (H301-HMTC-BL) Humidifying Module Temperature
64-2010 (H301-BC) Bubbling column
64-2007 (Oko-Touch) Touch screen display for Bold Line controllers
Login for U.S. Pricing

Temperature Controller (T-Unit)

The Bold Line T-Unit controls the temperature of the incubating chamber body, the heated glass cover, and of the humidifier collar. Several feedback mechanisms are available to suit your specific needs.

 Temperature Controller T-Unit

Sample Feedback:
In this configuration, feedback is provided by an external temperature sensor placed into a reference well that is very close to the specimen within the incubating chamber. The advantage of this configuration is the accuracy of temperature regulation. Simple manipulation is required to attach the thermocouple into the reference well using adhesive tape.

 StageTop Sample Feedback

Chamber Feedback:
In this configuration, feedback is provided by a temperature sensor embedded into the incubating chamber. Careful calibration performed at the factory guarantees the specimen temperature is maintained at the desired value. The advantage of this solution is simplicity of use.

 StageTop Chamber Feedback

Self Calibration:
This routine improves the accuracy of the chamber feedback mode above. It employes the two external temperature sensors of the T-Unit. One sensor measures the temperature of the lab, while the other is introduced into a reference well within the chamber, placed in the same position of sample. The calibration routine is easily launched via the OKO Touch and calculates the controller parameters to ensure a high degree of accuracy at the position of the sample.

 StageTop Self Calibration
 

Humidity Module

Humidifying the gas mixture before delivery to the climate chamber is an important step. Re-heating the gas helps prevent medium evaporation and avoids water condensation on glass and plastic surfaces.

 Humidity Module



StageTop System Arc

Next, select your insert:

 StageTop Incubator System Overview  StageTop Incubation Chambers  StageTop Chamber Sample Holder Inserts Touch Smart Box and Air Pump  gas control selection