Prechamber (BSC-PC)

Prechamber (BSC-PC)

The BSC-PC chamber allows multiple brain slices to be stored in vitro for several hours while maintaining excellent viability prior to study using either the BSC-HT or BSC-ZT.

  • 10 to 12 brain slices can be stored in vitro
  • 95% O2 /5% CO2 mixture bubbled through normal saline
  • Cyclic flow of oxygen enriched perfusate
  • Continuous permeation of stored slices
  • Slices remain viable for hours
  • Includes insert

Item# Description U.S. List Price Quantity
64-1525 (BSC-BUW) BSC-BU base unit compatible with Warner temperature controllers, includes connecting cable
65-0074 Model BSC-ZT (Zbicz Top) for Tissue Slice Chamber
65-0075 Model BSC-HT (Haas Top) for Tissue Slice Chamber
65-0076 Model BSC-PC Prechamber (for holding slices) Tissue Slice Chamber
64-0100 (TC-324B) Heater Controller, single channel, 110-120 VAC, 60Hz
64-0101 (TC-344B) Heater Controller, dual channel, 110-120 VAC, 60Hz
65-0073 Model BSC-BU (Base Unit) Tissue Slice Chamber
65-0045 Model TC-202A Bipolar Temperature Controller for use with PDMI-2, PSMI, CSMI, LU-CB-1, LU-CPC-CEH, and BSC-BU.
65-0078 Model BSC-AIR Aeration Element Replacement, Set of 2
65-0081 Model BSC-TUBE Base Unit (Model BSC-BU) Tubing Set Replacement, Tygon .031 x .093 (ID x OD)
65-0079 Model BSC-ORING Base Unit (Model BSC-BU) Replacement Gasket Set
65-0082 Model BSC-G10 Haas Top (Model BSC-HT) Tissue Insert Replacement, Set of 2
65-0083 Model BSC-HTC Haas Top (Model BSC-HT) Plastic Cover Replacement
65-0084 Model BSC-HT-AG Haas Top (Model BSC-HT) Ground Wire Replacement
65-0086 Model BSC-ZTC Zbicz Top (Model BSC-ZT) Plastic Insert Replacement
65-0087 Model BSC-PC-VAL Prechamber (Model BSC-PC) Valve Replacement
65-0608 Insert for Model BSC-PC Prechamber Tissue Slice Chamber
65-0090 Model BSC-MESH Haas Top (Model BSC-HT) Zbicz Top (Model BSC-ZT) Replacement Mesh 300 µm grid, 5 x 5 in, pkg. of 4
65-0088 Model BSC-ACC-KIT Base Unit, Haas & Zbicz Tops Accessory Kit (Replacement Screws, Fittings and Mesh)
64-1697 (BSC-HEW) Replacement heating wire for BSC-BUW
64-1591 (BSC-CABLE-W) BSC=BU connecting cable for Warner temperature controllers
65-0080 Model BSC-HE Base Unit Heating Element Replacement
65-0091 Model BSC-CABLE Base Unit (Model BSC-BU)/Temperature Controller (Model TC-102) Replacement Power Cable
65-0104 Output Cable, 6-Pin to Banana for 65-0045 Model TC-202A or 65-0073 Model BSC-BU
Login for U.S. Pricing

The Pre-chamber allows multiple brain slices to be stored in vitro for hours while maintaining excellent viability prior to study using either the BSC-HT or BSC-ZT.

  • 10 to 12 brain slices can be stored in vitro
  • 95% O2 /5% CO2 mixture bubbled through normal saline
  • Cyclic flow of oxygen enriched perfusate
  • Continuous permeation of stored slices
  • Slices remain viable for hours
  • Includes insert

The Pre-chamber (BSC-PC) chamber allows up to 12 brain slices to be safely stored in vitro while maintaining excellent slice viability.

A mixture of 95% O2 /5% CO2 is bubbled through physiological saline within the chamber. This initiates a circular flow of oxygen enriched saline which continuously permeates the slices. Slices can remain viable for hours while awaiting transfer to an examining chamber. Gas flow pressure should not exceed 5 p.s.i.

Insert is included.

Specifications
Dimensions (L x W x H) 11.27 x 4.89 x 9.54 cm
(4.435 x 1.928 x 3.757 in)
Weight 362.87 g
Volume of cup 22.7 ml