Perfusion Manifolds, MP/MPP/MM/ML Series

Perfusion Manifolds, MP/MPP/MM/ML Series

Warner perfusion manifolds can be used in any application where from 2 to 8 perfusion lines are required to be connected to a chamber or other device.

  • Manifold inputs converge to the common output with a minimum of dead space
  • Designed for use with PE-160, PE-50, and PE-10 polyethylene tubing
  • Can also be used with other tubings with similar dimensions

Item# Description U.S. List Price Quantity
64-0206 MP-2 Perfusion Manifold, 2 Inputs
64-0207 MP-3 Perfusion Manifold, 3 Inputs
64-0208 MP-4 Perfusion Manifold, 4 Inputs
64-0209 MP-5 Perfusion Manifold, 5 Inputs
64-0210 MP-6 Perfusion Manifold, 6 Inputs
64-0211 MP-8 Perfusion Manifold, 8 Inputs
64-0212 Model MPP-2 Perfusion Manifold, 2 Inputs
64-0213 Model MPP-3 Perfusion Manifold, 3 Inputs
64-0214 Model MPP-4 Perfusion Manifold, 4 Inputs
64-0215 Model MPP-5 Perfusion Manifold, 5 Inputs
64-0216 Model MPP-6 Perfusion Manifold, 6 Inputs
64-0217 Model MPP-8 Perfusion Manifold, 8 Inputs
64-0339 Model MPP-24 Perfusion Manifold, 24 Inputs
64-0219 PE Series and Theta Electrode Holders MP and MPP Series Manifolds - Diameter 9.5 mm (3/8")
64-0755 PE-160/10 Polyethylene Tubing PE-160, 10 ft.
64-0756 (PE-160/100) Polyethylene tubing, PE-160, 100 ft
99-0634 Replacement pin plugs, 10 pack for MP mainfolds
64-0203 Model MM-2 Perfusion Manifold, 2 Inputs
64-0204 Model MM-4 Perfusion Manifold, 4 Inputs
64-0205 Model MM-6 Perfusion Manifold, 6 Inputs
64-0750 (PE-10/10) Polyethylene tubing, PE-10, 10 ft
64-0751 (PE-10/100) Polyethylene tubing, PE-10, 100 ft
64-0752 PE-50/10 PE-50 Polyethylene Tubing, 10 ft L
64-0753 Model PE-50/100 PE-50 Polyethylene Tubing, 100 ft L
64-0200 Model ML-2 Perfusion Manifold, 2 Inputs
64-0201 Model ML-4 Perfusion Manifold, 4 Inputs
64-0202 Model ML-6 Perfusion Manifold, 6 Inputs
64-0199 ML-8 Perfusion Manifold ML Series 8 to 1
Login for U.S. Pricing

Warner's various perfusion manifold models are based upon the dimensions of the input vs. output polyethylene tubing used. When connected to a chamber via a short length of tubing, very rapid solution changes are possible.

MP Series

SF-77B MP manifolds are recommended for gravity fed perfusion systems. Input and output tubing are inserted with a friction fit. Manifolds should be ordered with inputs to match the number of solutions to be connected. Pin plugs to block unused inputs are also supplied. MP series manifolds are used with PE-160 tubing.

MPP Series

SF-77BMPP manifolds are suitable for systems in which solutions are pumped or at pressures greater than those generated in gravity fed systems. Input and output ports are 18 gauge stainless steel hypodermic tubing. PE-160 tubing slides over these ports to make a snug fit.

MM and ML Series
Designed to be part of the SF-77 Perfusion Fast-Step systems, these miniature manifolds are useful for applications involving small volumes or slow flow rates. Small diameter tubing is used with these models; PE-50 tubing for the input ports, and PE-10 or PE-50 tubing for the MM or ML Series output ports, respectively.
MM Series

ML Series
Specifications
Perfusion Manifold MP Series MPP Series MM Series ML Series
Material PTFE Delrin Delrin Delrin
Large Diameter 9.4 mm 9.4 mm 8.0 mm 8.0 mm
Small Diameter 6.3 mm 6.3 mm 4.7 mm 4.7 mm
Body Length 22 mm 21 mm 18 mm 18 mm
Volume 3.5 µl 4 µl 5 µl 5 µl
Input Tubing PE-160 PE-160 PE-50 PE-50
Output Tubing PE-160 PE-160 PE-10 PE-50
Drawing
Delrin is a trademark of E.I. du Pont de Nemours & Co.

Inner and Outer Tubing Measurements

ID OD
PE-10 .28 .61
PE-50.58 .96
PE-90 .86 1.27
PE-1601.14 1.57
DOCUMENT DESCRIPTION
MPP Manifolds (2001.07.12).pdfPerfusion Manifolds (MP/MPP/MM/ML) Instruction Sheet