Nitric Oxide Measurement System (inNO-T)

Nitric Oxide Measurement System (inNO-T)

The most technically advanced nitric oxide electrochemical detection system on the market today.

  • New Dual Channel System Option
  • Uses amiNO NO sensors with a resolution of 0.01 nM [NO] (i.e. 0.1 pA current)
  • First available [NO] system to have temperature compensation
  • Virtually eliminates base line drift due to temperature changes
  • System includes meter, data acquisition software, 2 types of NO sensors, and calibration kit

Item# Description U.S. List Price Quantity
69-3050 inNO-T nitric oxide measurement system with aniNO-100 sensors, 1 channel, 110 VAC
69-3052 inNO-T nitric oxide measurement system with amiNO-600 sensors, 1 channel, 110 VAC
69-0048 inNO-T nitric oxide measurement system with amiNO-600 sensors, 1 channel, 110 VAC
69-0050 inNO-T nitric oxide measurement system with amiNO-FLAT sensors, 1 channel, 110 VAC
69-3054 inNO-T nitric oxide measurement system with amiNO-100 sensors, 2 channel, 110 VAC
69-3056 inNO-T nitric oxide measurement system with amiNO-600 sensors, 1 channel, 110 VAC
69-3058 inNO-T nitric oxide measurement system with amiNO-IV sensors, 2 channel, 110 VAC
69-3060 inNO-T nitric oxide measurement system with amiNO-FLAT sensors, 2 channel, 110 VAC
69-3051 inNO-T nitric oxide measurement system with amiNO-100 sensors, 1 channel, 220 VAC
69-3053 inNO-T nitric oxide measurement system with amiNO-600 sensors, 1 channel, 220 VAC
69-0049 inNO-T nitric oxide measurement system with amiNO-IV sensors, 1 channel, 220 VAC
69-0051 inNO-T nitric oxide measurement system with amiNO-FLAT sensors, 1 channel, 220 VAC
69-3055 inNO-T nitric oxide measurement system with amiNO-100 sensors, 2 channel, 220 VAC
69-3057 inNO-T nitric oxide measurement system with amiNO-600 sensors, 2 channel, 220 VAC
69-3059 inNO-T nitric oxide measurement system with amiNO-IV sensors, 2 channel, 220 VAC
69-3061 inNO-T nitric oxide measurement system with amiNO-FLAT sensors, 2 channel, 220 VAC
69-0010 amiNO-100 NO Sensor, 100 µm tip, 2550 pA/nM (typical 35 pA/nM), 1 pack
69-0011 amiNO-600 NO Sensor, 600 µm tip, 150250 pA/nM (typical 200 pA/nM), 2 pack
69-0006 amiNOIV, 700 µm tip, 150250 pA/nM (typical 200 pA/nM), 2 pack
69-0007 amiNOFLAT, 3 prong chicken footprint, 250700 pA/nM (typical 400 pA/nM), 1 pack
69-0052 (TEMP-1) Temperature probe for In-NOT System
69-0016 SensoReady Electrode Polarizer
69-0029 Adapter, LIMΩ connector to amiNO sensor
69-0037 Nitrite Standards, 50 ml
69-0038 Calibration Vials, 5 pack
72-1972 Magnetic stirrer, 115 VAC
72-1973 Magnetic stirrer, 230 VAC
72-1922 Electrode holder and stand
Login for U.S. Pricing

The inNO-T Nitric Oxide Measuring System combines a nitric oxide configured potentiostat and a sophisticated software controlled data acquisition system into one compact battery powered unit. When used with the amiNO Series NO sensors, the inNO-T provides an NO detection sensitivity increase of up to 100 times that of any other electrochemical detection system on the market today. Its state of the art battery powered design allows the unit to run continuously for up to 5 years, making it ideal for any electrically isolated and/or portable application.

The inNO-T system is the first available nitric oxide system to include temperature compensation which eliminates baseline drift caused by temperature changes. This further enhances ite devices detection limit and data reliability. A temperature probe is supplied with each system. Its internal 24 bit A/D converter and built in digital notch filtering allows for accurate, noise free, detection of nitric oxide levels of less than 0.01 nM. The 24 bit A/D technology also gives the unit a dynamic range in excess of 16,000,000 to 1. Its sophisticated control and analysis software can be linked to any computer system that utilizes Windows 95/98, 2000 or NT via the inNO-T's internal RS-232 interface.

amiNO Series NO Sensors

  • Combination sensors; no external reference electrode required
  • Mechanically rugged membrane
  • Sensors covered with proprietary triplecoat gas permeable membrane to guarantee selectivity and very fast response time
  • Sensors completely shielded from environmental/electrical noise
  • All sensors work with inNO and inNO-T meters as well as many other currently available meters
  • One calibration procedure; simple, easy, no expensive chemicals

amiNO Sensor Application Selection Guide

Application First Choice(s) Second Choice(s)
Measuring NO released from cells/large flat tissue amiNO-FLAT amiNO-600 or amiNO-IV
In vivo measurements and other insertion applications amiNO-IV amiNO-600
Measuring NO in small volumes or restricted space amiNO-100 amiNO-7, amiNO-30 or amiNO-600

Measuring μm levels of NO

amiNO-100 amiNO-30
Following the decomposition of an NO producing compound amiNO-600 or amiNO-100 amiNO-IV
Measuring very low levels of NO (below 50 nM) amiNO-600 or amiNO-IV amiNO-100
Indirect measurement of Nitrate and Nitrite amiNO-600, depending on expected level amiNO-100
Training new staff or students amiNO-100 amiNO-600
Specifications

inNO-T Meter Specifications

Current Scale ± 2,500,000.0 pA
Concentration Scale ± 1,000,000.0 nM
Resolution 0.01 nM (0.1 pA)
Screen Meter 7.5 digit meter
Recording Speed 1 to 1000 sec/div
Power Replaceable battery
Dimensions, H x W x D 76 x 229 x 203 mm (3 x 9 x 8 in)
Temperature Range 0° to 50°C, inNO-T only
Temperature Resolution 0.01°C, inNO-T only
Temperature Sensor < 0.50 mm tip, 120 mm long, inNO-T only

 

amiNO Sensor Specifications

ModelTip SizeFeaturesTypical Sensitivity
amiNO-100 100 µm
  • Extremely stable background
  • Resists breakage
  • In vivo measurements
  • Very consistent
  • Very reproducible
25-50 pA/nM
amiNO-600 600 µm
  • Exceptional sensitivity and
    baseline stability
  • Very rugged membrane and
    flexible body
  • Very durable
150-250 pA/nM
amiNO-IV 700 µm
  • Very sharp metallic tip for insertion and
    penetration of tissue, no extra needles
    or catheters are needed
  • Up to 100 times more sensitive than
    other commercially available sensors
  • Sub nano-molar detection limit
  • Special membrane survives numerous
    insertions
  • Very stable
  • Low background current
150-250 pA/nM
amiNO-FLAT 3-prong chicken footprint
2 cm x 1 cm
  • For measuring NO on mono-layer
    cultured cells and in flat tissues
  • Rugged membrane
  • Exceptional sensitivity
  • Low background noise
250-700 pA/nM