NeuroLog System Application Amplification Modes

NeuroLog System Application Amplification Modes

At the heart of the NeuroLog system range are the many possible amplification modules, which can be used to make intracellular or extracellular microelectrode recordings; multi-channel EMG, EEG or ECG recordings or recordings from strain gauges or pressure transducers.

Item# Description U.S. List Price Quantity
72-4223 Replacement Dome for NL108T4 Pressure Transducer - 72-4222, pkg of 1
65-0231 NL108L2 Lead for NL108T2 to NL108A
72-4222 NL108T4 Pressure Transducer, pkg of 1
65-0229 NL108T2 Disposable Pressure Transducer, pkg of 1
65-0227 NL108A Pressure Amplifier
65-0259 NL530 4-Channel Conditioner
65-0242 NL144 4-Channel High Pass Filter, without Notch Filter*
65-0240 NL135 4-Channel Low Pass Filter, with 50 Hz Notch Filter
65-0277 NL820A Isolation Amplifier, 4 channel
65-0362 (NL844) 4-Channel preamplifier
65-0630 NL405 Width Delay
65-0248 NL304 Period Generator
72-4220 NL412 Pulse Generator - General Purpose, Hand Held
65-0222 NL102G DC Pre-Amplifier including Headstage and NL412 Pulse Generator
65-0642 NL100RK Preamplifier and Stimulus Relay
65-0323 NL985 Loudspeaker
65-0236 NL120S Audio Amplifier
65-0243 NL201 Spike Trigger
65-0237 NL125 Filter (Low Cut, High Cut, and 50 Hz Notch)
65-0225 NL106 AC-DC Amplifier
65-0224 NL104A AC Preamplifier
65-0220 NL100AK Headstage
Login for U.S. Pricing
Extracellular AC recording system with spike discrimination and audio monitoring Modules Order No. Add Each to Cart
View PDF
NL100AK 65-0220
NL104A 65-0224
NL106 65-0225
NL125 65-0237
NL201 65-0243
NL120S 65-0236
NL985S 65-0323
The NL100RK - Record from and then electrically lesion your recording site without moving or disconnecting the electrode Modules Order No. Add Each to Cart
View PDF
NL100RK 65-0642
NL104A 65-0224
How to avoid ground loops when recording from multiple NL100AK AC preamplifier headstages. Modules Order No. Add Each to Cart
View PDF
NL100AK (x2) 65-0220
A typical intracellular (DC) recording configuration Modules Order No. Add Each to Cart
View PDF
NL102G 65-0222
NL412 72-4220
NL125 65-0237
NL106 65-0225
NL304 65-0248
NL405 (x2) 65-0630
4-Channel isolated amplifier system with filtering and signal conditioning Modules Order No. Add Each to Cart
View PDF
NL844 65-0362
NL820A 65-0277
NL135 65-0240
NL144 65-0242
NL530 65-0259
Measurement of physiological pressures with the NeuroLog System Modules Order No. Add Each to Cart
View PDF
NL108A 65-0227
NL108T2 65-0229
NL108T4 72-4222
NL108L2 65-0231
NL108L4
NL72-4223 72-4223

Please note that as well as the modules indicated above, each application note requires a NeuroLog Case & Power Supply Unit (NL900D or NL905) and possibly some cables and cable adaptors.

Specifications