Isometric Force Transducers, HA-HSE Model F10, ultra high resolution

 Isometric Force Transducers, HA-HSE Model F10, ultra high resolution

The HSE-HA F10 isometric force transducer is a lower force range, higher resolution version of the F30 isometric force transducer. The HSE-HA F30 is a sensitive, reliable and rugged isometric force transducer suitable for use with very small muscle/tissue specimens.

Item# Description U.S. List Price Quantity
73-0841 Isometric Transducer F10 for PLUGSYS Amplifier
73-2661 Isometric Transducer F10 for Harvard Apparatus Transducer Amplifier
73-3742 HSE Isolmetric Force Transducer F10 for ADI Amplifier
73-2663 Isometric Transducer F10 for Gould Series 6600 Amplifier
73-2662 Isometric Transducer F10 for Grass Amplifier, 6-Pin Cannon Connector
Login for U.S. Pricing
  • Ultra-high resolution of ±0.5 mg
  • Low vertical displacement (6 µm/g)
  • Suitable for small tissue samples like papillary muscle, Purkinje fibers and vessel rings
  • Force range of ±10 grams (±0.1 N)

The HSE-HA F10 isometric force transducer is a lower force range, higher resolution version of the F30 isometric force transducer. The HSE-HA F30 is a sensitive, reliable and rugged isometric force transducer suitable for use with very small muscle/tissue specimens. The ultra-low vertical displacement of the transducer means that true isometric measurements can be made. The low seismic sensitivity of the HSE F30 minimizes the influence of environmental vibrations on the force recordings which result in very stable baselines. The design of the unit (no internal wires suspending the transducer head) means that this transducer will stand up to years of use. This is a full resistance bridge transducer which can be connected to the HSE-HA TAM-A and TAM-D strain gauge amplifiers, see page I33. Connectors are also available for Harvard Apparatus Ltd., Grass and Gould strain gauge amplifiers. * Note: This transducer is produced under licence from DLR: Deutsche Forschungsanstalt für Luft- und Raumfahrt e.V., D-51140 Köln.

Specifications73-084173-266173-266373-2662
Bridge Resistance1 KΩ, nominal, full ohmic bridge1 KΩ, nominal, full ohmic bridge1 KΩ, nominal, full ohmic bridge1 KΩ, nominal, full ohmic bridge
CertificationsCECECECE
Connection Cable1.5 m L with 6-pin Binder Plug (HSE System)1.5 m L with 6-pin Binder Plug (HSE System)1.5 m L with 6-pin Binder Plug (HSE System)1.5 m L with 6-pin Binder Plug (HSE System)
Excitation AC or DC3.0 mV/V g3.0 mV/V g3.0 mV/V g3.0 mV/V g
For use with X Amplifier TypePLUGSYSHarvard AppartusGould 6600Grass
Hysteresis< 0.1%< 0.1%< 0.1%< 0.1%
Isometric Quotient IQgggg
Maximum Load100%100%100%100%
Natural Frequency180 Hz, nominal180 Hz, nominal180 Hz, nominal180 Hz, nominal
Resolution (Noise)0.5 mg0.5 mg0.5 mg0.5 mg
Sensitivity3.0 mV/V3.0 mV/V3.0 mV/V3.0 mV/V
Transducer Depth English2.82.82.82.8
Transducer Depth Metric70707070
Transducer Height English0.90.90.90.9
Transducer Height Metric22222222
Transducer Width English0.90.90.90.9
Transducer Width Metric22222222
Weight English7777
Weight Metric200200200200