PERI ST ALTIC PUMP S MS Multi-Channel Pump Heads for MCP & BVP Pump Drives PC4 73-3030 MS-3 Pump Head PC4 73-3033 MS/CA 8-6 Pump Head PERISTALTIC PUMPS MS Multi-Channel Pump Heads for MCP & BVP Pump Drives 76 MS and MS/CA Cassettes Flow Rate Range MS-3 3 Channels PC4 73-3030 Flow Rates ml/min per Channel 3-Stop Collared Tubing ID mm 0.13 0.19 0.25 0.38 0.44 0.51 0.57 0.64 0.76 Min. Max. MS/CA 4-12 4, 8, 12 or 16 Channels PC4 73-3038 Flow Rates ml/min per Channel Min. Max. MS/CA 8-6 8, 16, or 24 Channels PC4 73-3033 Flow Rates ml/min per Channel Min. Max. 0.002 0.003 0.005 0.011 0.014 0.019 0.023 0.029 0.04 0.053 0.06 0.69 0.078 0.084 0.10 0.11 0.12 0.14 0.16 0.18 0.19 0.23 0.27 0.32 0.36 0.42 0.4 0.73 1.2 2.6 3.4 4.5 5.5 6.9 9.6 13 14 17 19 20 23 26 30 34 39 42 47 55 65 76 87 100 0.001 0.003 0.004 0.009 0.012 0.016 0.019 0.024 0.033 0.044 0.050 0.056 0.063 0.067 0.075 0.083 0.094 0.10 0.12 0.13 0.13 0.15 0.17 0.19 0.21 0.24 0.22 0.51 0.91 2.1 2.8 3.8 4.7 5.8 8.0 11 12 13 15 16 18 20 23 25 28 30 32 37 41 46 52 57 0.002 0.003 0.005 0.011 0.014 0.019 0.024 0.03 0.042 0.057 0.064 0.073 0.083 0.090 0.10 0.11 0.13 0.15 0.17 0.19 0.21 0.25 0.29 0.33 0.37 0.43 0.33 0.67 1.1 2.6 3.5 4.6 5.7 7.2 10 14 15 18 20 22 24 27 32 36 42 46 50 59 69 79 89 100 PC4 73-3038 MS/CA 4-12 Pump Head 0.89 0.95 1.02 1.09 MS-3 PUMP HEAD Ideal for sensitive substances requiring a gentle pressure setting Uses spring-loaded tube bed set Transparent protection cover for easy monitoring of the pump head 0.002 to 100 ml/min flow rates Uses 3-stop collared tubing, 0.13 to 3.17 mm ID, see page 78 Back pressure has max of 1.5 bar (22 PSI) 1.14 1.22 1.3 1.42 1.52 1.65 1.75 1.85 2.06 2.29 2.54 2.79 3.17 MS/CA 4-12 PUMP HEAD MS/CA Click ‘n’ Go Cassettes are included 12 Rollers for extremely low pulsation Each channel can take different tube sizes Easy and rapid tube change-over; even while pump is running 0.001 to 57 ml/min flow rates Uses 3-stop collared tubing, 0.13 to 3.17 mm ID, see page 78 Back pressure has maximum of 1.0 bar (14.5 PSI) *Note: Approximate values: determined with water at 22°C, no differential pressure, with Tygon® Tubing Order # PC4 73-3030 PC4 73-3038 PC4 73-3046 PC4 73-3039 PC4 73-3033 PC4 73-3034 Product MS-3 Pump Head for BVP/MCP Pump Drives MS/CA 4-12 Pump Head for BVP/MCP Pump Drives 3V Tube Bed Set for SB Pump Head MS/CA 4-12 Extension Block, 4 Channel MS/CA 8-6 Pump Head for BVP/MCP Pump Drives MS/CA 8-6 Extension Block, 8 Channel MS/CA 8-6 PUMP HEAD MS/CA Click ‘n’ Go Cassettes are included Each channel can take different tube sizes Easy and rapid tube change-over; even while pump is running 6 rollers 0.002 to 100 ml/min Flow Rates Uses 3-stop collared tubing, 0.13 to 3.17 mm ID, see page 78 Back pressure has maximum of 1.0 bar (14.5 PSI) Harvard Apparatus phone 508.893.8999 toll free U.S. 800.272.2775 fax 508.429.5732 www.harvardapparatus.com