Syringe Pumps PHD 22/2000 Advanced Syringe Pumps SYRINGE PUMPS PHD 22/2000 Syringe Pumps Infusion Only* SYRINGE PUMP VERSIONS Standard Syringe Pumps STANDARD 2-SYRINGE 6/10 MULTI-RACK 4 X 140 MULTI-RACK MICROLITER RACK Remote Syringe Pumps STANDARD 2 SYRINGE 6/10 MULTI-RACK 4 X 140 MULTI-RACK MICROLITER RACK Push/Pull Syringe Pumps STANDARD REMOTE – – – – PC4 70-2020 PC4 70-2120 PC4 71-2020 PC4 71-2120 PC4 70-2019 PC4 70-2119 PC4 71-2019 PC4 71-2119 PC4 70-2100 PC4 70-2103 PC4 70-2104 PC4 70-2105 PC4 71-2100 PC4 71-2103 PC4 71-2104 PC4 71-2105 PC4 70-2101 PC4 70-2106 PC4 70-2107 PC4 70-2108 PC4 71-2101 PC4 71-2106 PC4 71-2107 PC4 71-2108 PC4 70-2102 PC4 70-2109 PC4 70-2110 PC4 70-2111 PC4 71-2102 PC4 71-2109 PC4 71-2110 PC4 71-2111 PC4 70-2000 PC4 70-2003 PC4 70-2004 PC4 70-2005 PC4 71-2000 PC4 71-2003 PC4 71-2004 PC4 71-2005 PC4 70-2001 PC4 70-2006 PC4 70-2007 PC4 70-2008 PC4 71-2001 PC4 71-2006 PC4 71-2007 PC4 71-2008 PC4 70-2002 PC4 70-2009 PC4 70-2010 PC4 70-2011 PC4 71-2002 PC4 71-2009 PC4 71-2010 PC4 71-2011 Standard Force High Force Infusion/Withdrawal Standard Force High Force Programmable Standard Force High Force PHD 22/2000 Advanced Syringe Pumps *Infusion Only models do not include an anti-siphon bracket or a retaining bracket. These can be ordered as a special. Harvard PHD 22/2000 Pump Series Kits & Upgrades ORDER # PC4 70-2012 PC4 70-2013 PC4 70-2014 PC4 70-2015 Upgrades 2 Continuous Flow Tubing Segment This continuous flow tubing segment is used with the PHD 22/2000 or PHD ULTRA™ Push/Pull Syringe Pumps. When used with the programmable model it makes continuous 24/7 flow possible. PRODUCT 1 Syringe Rack Kits PHD 22/2000 6/10 Multi Syringe Rack PHD 22/2000 4 x 140 Multi Syringe Rack PHD 22/2000 Microliter Multi Syringe Rack PHD 22/2000 Anti-Siphon Kit (Infusion Only Pump) Tubing Segment Specifications TUBING TUBING LENGTH MAX. PRESSURE VALVE MATERIALS 0.062 in. ID Tygon® tubing 3 x 112 in sections 15 p.s.i. Polycarbonate, silicone PC4 70-2016 PC4 70-2017 PC4 70-2018 1 PHD 22/2000 Infusion Only to Infusion/Withdrawal PHD 22/2000 Infusion/Withdrawal to Programmable PHD 22/2000 Infusion Only to Programmable These multiple syringe racks will fit any PHD 22/2000 series syringe pump listed above and are easily interchangeable. Upgrades are available for Infusion Only and Infusion/Withdrawal models of PHD 22/2000 series pumps. All upgrades must be factory installed. Order # PC4 61-0270 Product Continuous Flow Tubing Segment 2 Remote Extension Cables Replacement cables for PHD 22/2000 Remote Syringe Pumps including the PHD 22/2000 Hpsi, see page 33, are available in 1.5 m (5 ft) and 9.1 m (30 ft) lengths. These cables can also be used to increase or decrease the distance between the syringe pumping mechanism and the control box. PHD 22/2000 References Mazutis, L., et al., Droplet-Based Microfluidic Systems for High-Throughput Single DNA Molecule Isothermal Amplification and Analysis, Anal. Chem., 2009, Vol. 81, 4813-4821 Yeoma, J., et al., Microfabrication and characterization of a silicon-based millimeter scale, PEM fuel cell operating with hydrogen, methanol, or formic acid, Sensors and Actuators, 2005, Vol. B107, 882-891. Guillot, P., et al., Towards a continuous microfluidic rheometer, Microfluid Nanofluid, 2008, Vol. 5, 619-630. Utada, A.S., et al., Monodisperse Double Emulsions Generated from a Microcapillary Device, Science, 2005, Vol. 308, 537. Liu Tsang, V., et al., Fabrication of 3D hepatic tissues by additive photopatterning of cellular hydrogels, FASEB Journal, 2007, Vol. 21, 790-801. Order # PC4 72-0199 PC4 72-1405 PC4 72-2022 Product Remote Extension Cable, 1.5 m (5 ft) Remote Extension Cable, 9.1 m (30 ft) RS-232 D-Sub 9-pin to RJ11-4 Connection Cable * ush/Pull pump can hold syringes up to 140 ml if full stroke is not required. Larger syringes P will not fully infuse or withdraw. Max of 50 ml syringe if full stroke is required. Harvard Apparatus phone 508.893.8999 toll free U.S. 800.272.2775 fax 508.429.5732 www.harvardapparatus.com 31