Pump Models
The Pump 11 Elite Syringe Pumps are available in two configurations
designed for different operating environments and varying degrees of
operational flexibility.
1. Infusion Only (single and dual syringe models):
This model
supports infusion operations at user-defined flow rates and
with selectable target volume or time values to control the
total infusion volume. The Infusion Only models do not
include programmable, user-defined Methods.
2. Infusion/Withdrawal Programmable (single and dual syringe
models):
This model supports infuse only, withdraw only,
infuse/withdraw and withdraw/infuse operations at user-
defined flow rates and with selectable target volume or time.
This model also allows users to create and store up to two
user-defined Methods of 50 steps each on the pump.
Accessories
A full range of accessories are compatible with the Pump 11 Elite
including syringe heaters, in-line heaters and coolers, nanofluidic
circuits, connectors, tubing, syringes and more.
Program Description
To operate the Pump 11 Elite, the user defines all the required
parameters for infusing or withdrawing liquids through a Method.
This may be a Quick Start Method, Pre-Programmed or User-Defined
Method. The basic operation is a simple 3-step procedure:
1. Select a method
2. Enter operating parameters
3. Preview or Run your method
Quick Start Methods are simple infusions, withdrawals or a
combination (depending upon the model). Custom user-defined
Methods can be created when more advanced programming is
required. The setup for a custom Method is easy using the standard
profiles found on all Infusion/Withdrawal Programmable Elite Models.
The list of available profiles is:
By programming custom (user-defined) Methods into the pump,
multi-user errors are reduced. Easily transfer Methods to other pumps
and/or download Methods from a PC. Forget having to duplicate
Method-development efforts for each new pump added to your system.
Alarms
There are several alarms available on the Model 11 Elite Syringe Pumps:
· End of Run
· Near End of Run
· Power Up
· Stall
Advanced Documentation Features
· Download experimental parameter information to PC
· Alphanumeric keypad for method naming
Adjustable Force
The maximum linear force of the Pump 11 Elite is 16 kg (35 lbs).
Depending upon the syringes you are working with and your overall
experimental setup you may want to adjust the amount of force
applied to the pusher block. You can select a percentage of the total
force from 20% to 100%. Refer to the user's manual for suggested
force level settings.
Constant Rate
Gradient (binary)
Ramp
Autofill
SYRINGE PUMPS
Pump 11 Elite
12
CONTROL MULTIPLE PUMPS VIA
DAISY CHAIN WITH RS-485
Pump 11 Elite
SYRINGE PUMPS