Linear Pneumotachometer, Non-Heated

Linear Pneumotachometer, Non-Heated

These Linear Pneumotachometers have a special screen design which assures a linear signal over a range of flow rates and have minimum dead space.

  • For use with Differential Pressure Transducers
  • Available heated or non-heated

Please see Full Description for more details.

For Heated Pneumotachometers please see: Heated Pneumotachometers

Item# Description U.S. List Price Quantity
59-9366 Non-heated linear pneumotachometer, 0 to 160 L/min flow range, dead space vol 14.18 ml
59-9369 Non-heated linear pneumotachometer, 0 to 160 L/min flow range, dead space vol 13.87 ml
59-9363 Non-heated linear pneumotachometer, 0 to 100 L/min flow range, dead space vol 18.15 ml
59-9360 Non-heated linear pneumotachometer, 0 to 35 L/min flow range, dead space vol 11.45 ml
59-9357 Non-heated linear pneumotachometer, 0 to 35 L/min flow range, dead space vol 8.74 ml
59-9354 Non-heated linear pneumotachometer, 0 to 35 L/min flow range, dead space vol 6.81 ml
59-9345 Non-heated linear pneumotachometer, 0 to 10 L/min flow range, dead space vol 5.06 ml
59-9351 Non-heated linear pneumotachometer, 0 to 10 L/min flow range, dead space vol 3.28 ml
59-9348 Non-heated linear pneumotachometer, 0 to 10 L/min flow range, dead space vol 2.65 ml
59-9342 Non-heated linear pneumotachometer, 0 to 10 L/min flow range, dead space vol 1.66 ml
59-9336 Non-heated linear pneumotachometer, 0 to 10 L/min flow range, dead space vol 1.30 ml
59-9339 Non-heated linear pneumotachometer, 0 to 10 L/min flow range, dead space vol 1.06 ml
59-9330 Non-heated linear pneumotachometer, 0 to 5 L/min flow range, dead space vol 0.71 ml
59-9333 Non-heated linear pneumotachometer, 0 to 5 L/min flow range, dead space vol 0.59 ml
59-9324 Non-heated linear pneumotachometer, 0 to 3 L/min flow range, dead space vol 0.39 ml
59-9327 Non-heated linear pneumotachometer, 0 to 3 L/min flow range, dead space vol 0.30 ml
Login for U.S. Pricing

A pneumotachometer converts the flow of gases through it into a proportional signal of pressure difference on either side of a central screen. These Linear Pneumotachometers have a special screen design which assures a linear signal over a range of flow rates and have minimum dead space.

  • For use with Differential Pressure Transducers
  • Available heated or non-heated

The Heated Pneumotachometers require a Heater Controller and are recommended when condensation of water vapor occurs. The heater shell is removable if heating is not required. Two Heater Controllers are available to heat one or two Pneumotachometers. The cable from the Pneumotachometer heater shell connects to the rear panel of the Controller.

Both the Heated and Unheated Pneumotachometers are linear and bidirectional (produce signals for gas flow in either direction). They are available in seven flow ranges.

All Pneumotachometers are supplied with calibration curves. Adapter diameters measuring 7.5, 10.5, 15 or 22 mm are standard medical tapers. All other connectors are straight. When selecting a Pneumotachometer it is important to select the appropriate adapter size and style to match existing equipment.

 

For Heated Pneumotachometers please see: Heated Pneumotachometers

Specifications
Item            

DP input to
transducer signal
pressure(mm/H2O)

Dead space
volume (ml)

Flow range
(L/min)
 

Recommended differential
pressure transducer 

Species                
59-9327  10  0.30  0 to 3   600349 or 600350  Mouse 
59-9324  10  0.39  0 to 3
 600349 or 600350
 Mouse 
59-9333  8  0.59  0 to 5 
 600348 or 600349  Mouse / Rat
59-9330  8  0.71  0 to 5   600348 or 600349
 Guinea Pig 
59-9339  10  1.06  0 to 10   600349 or 600350  Cat
59-9336  10  1.30  0 to 10 
 600349 or 600350
 Cat 
59-9342  7  1.66  0 to 10 
 600348 or 600349
 Rabbit 
59-9348  7  2.65  0 to 10 
 600348 or 600349
 Rabbit 
59-9351  7  3.28  0 to 10 
 600348 or 600349
 Rabbit 
59-9345  7  5.06  0 to 10 
 600348 or 600349
 Rabbit 
59-9354  7  6.81  0 to 35  600348 or 600349
 Small Dog 
59-9357  7  8.74  0 to 35
 600348 or 600349
 Small Dog
59-9360  7  11.45  0 to 35
 600348 or 600349
 Small Dog 
59-9363  10  18.15  0 to 100
 600348 or 600349
 Medium Dog 
59-9369  16  13.87  0 to 160  600350  Large Dog 
59-9366  16  14.18  0 to 160  600350  Large Dog