Large Rectangular Open Bath Chamber (RC-27)

Large Rectangular Open Bath Chamber (RC-27)

The RC-27 is a large bath chamber suitable for studies requiring smooth solution flow with a large viewing area.

  • Accommodates large tissue sections or brain slices
  • Large rectangular bath area accommodates insertion of coverslips up to 12 x 24 mm
  • Large optical imaging area
  • Can be used with either upright or inverted microscopes
  • Slice anchors available

Item# Description U.S. List Price Quantity
64-0238 Very Large Bath RC-27 Recording Chamber, 413 ul
64-0282 Series 20 Plain Platform, Model P-6
64-0289 Series 20 Heater Platform, Model PH-6
64-1527 PM-6 Chamber platform with magnetic clamps
64-1506 (RPC-1) Replacement platform clamps and screws for P-1, P-3, P-4, P-5, and P-6 platforms, 2 pack
64-0194 Slice Anchor - Stainless Steel for RC-27 Chamber, 1.0 mm, SHD-27H/10
64-0193 Slice Anchor - Stainless Steel for RC-27 Chamber, 1.5 mm, SHD-27H/15
64-0192 Slice Anchor - Stainless Steel for RC-27 Chamber, 2.0 mm, SHD-27H/2
64-0709 CS-24/50 Coverslips for use with RC-27, RC-27L, RC-27N, RC-27NE, RC-28, and RC-29, 0.15 mm (0.006 in)24 x 50 mm, pkg of 65
64-0755 PE-160/10 Polyethylene Tubing PE-160, 10 ft.
64-0756 (PE-160/100) Polyethylene tubing, PE-160, 100 ft
64-0106 Model CC-28 Cable Assemblies with Connector for TC-324B/344B
64-0107 TA-29 Replacement Cable with Bead Thermistor
64-0274 Heater Elements (2) for PH (Heater) Platforms with Mounting Pads and Screws, RH-2
64-1401 Left Hand Suction Tube, Series 20 Classic Design for use with RC-27, RC-27L, RC-27NE
Login for U.S. Pricing

The RC-27 requires a platform (P-6, PH-6, or PM-6) and stage adapter to complete the assembly for mounting onto a microscope.

Each chamber is supplied with a package of #1 thickness glass coverslips (CS-24/50, 24 x 50 mm, 50/pkg) and 10 ft of PE-160 tubing. Available slice anchors sold separately.

Material Polycarbonate
Bath dimensions
(L x W x H)
38 x 12.5 x 4 mm
Volume, by depth 413 μl/mm
Bottom coverglass 24 x 50 mm
Input tubing
(ID x OD)
1.14 x 1.57 mm (PE-160)
Aspirator coupling 1.67 mm (OD)

27 Drawing

  1. Effects of Oleic Acid on Distinct Populations of Neurons in the Hypothalamic Arcuate Nucleus Are Dependent on Extracellular Glucose Levels,
    R. Wang1, C. Cruciani-Guglielmacci2, S. Migrenne2, C. Magnan2, V. E. Cotero1 and V. H. Routh1,
    J Neurophysiol 95: 1491-1498, 2006. First published November 23, 2005
  2. Reactive oxygen species formation in the transition to hypoxia in skeletal muscle,
    Li Zuo and Thomas L. Clanton,
    Am J Physiol Cell Physiol 289: C207-C216, 2005
Integrated Components Brochure_06_7_11.pdfIntegrated Components for Live Cell Imaging Brochure
RC-27 (080724).pdfRC-27 Chamber Instructions
perfusion_strategies.pdfPerfusion Strategies (Leinders-Zufall)