ISOHEART Data Acquisition Software for Isolated Heart Experiments

ISOHEART Data Acquisition Software for Isolated Heart Experiments

For all types of isolated heart studies. Online evaluation of a wide range of signals and classical standard parameters.

Item# Description U.S. List Price Quantity
73-4792 HA-HSE ISOHEART SOFTWARE FOR ISOLATED HEART STUDIES FOR WINDOWS XP, WINDOWS 7 AND HIGHER (32 AND 64 BIT)
73-0237 LVP ADVANCED SOFTWARE MODULE
73-2715 MONOPHASIC ACTION POTENTIAL (MAP) SOFTWARE MODULE
73-0224 PSM AND PPG CONTROL FOR WIN SOFTWARE MODULE
73-3819 FLOW CONTROLLED DRUG ADDITION SOFTWARE MODULE (WITH P11 PLUS, P22 OR PHD2000 SYRINGE PUMPS)
Login for U.S. Pricing


The HA-HSE ISOHEART data acquisition and monitoring software can be adapted to virtually any isolated heart system. Acquisition can cover signals such as left ventricular pressure, aortic pressure, aortic flow, atrial pressure, atrial flow, coronary flow, pO2, pCO2, pH, temperature, etc. Various parameters can be derived from these signals, e.g. systolic, diastolic, mean and rate (frequency) values for pressures, +/-dLVP/dt contractility index CI, minimal, maximal, and mean flows, etc.

All acquired signals and all calculated parameters can be displayed in two graphic windows (Detail and Trend) according to the settings of the user. Complete raw data of experiment are stored on hard disk and can be replayed any time later after experiment. Includes graphic selection of trend data points for easy data reduction.

ISOHEART software is available in a basic version which includes the minimal necessary algorithms. Optional software modules are available to upgrade to a more complex system that includes all the available algorithms.  The configuration of the system is defined in configuration and can be set by the user in the menu. The user only needs to calibrate the signals and fix the graphics scaling. All the hardware definitions and algorithms can be defined by the user. The configuration files can be changed according to the needs and used in combination with a set of different configuration files to match the different experiments.

ISOHEART software can acquire a maximum of 8 or 16 channels (depending on hardware used  73-3330 (16 ch), 73-4817 (8 ch), 73-4818 (16 ch) or 73-0161 (16 ch), i.e. up to 16 different raw signals can be handled.

Easy to Use (comes with predefined settings file if the application is known)

  • Choose available signals to acquire and display.
  • Choose from possible parameters to evaluate and display.
  • Enter experimental protocol.
  • Calibrate. (Calibration can be taken from previous experiment.)  
  • Start data acquisition. 
  • Data reduction and evaluation.

During data acqusition, all acquired signals and derived parameaters are displayed on screen. All raw data and trend data are stored. Data reduction tools are included. Export of data to any statistc package are possible.

Additional available software modules:

73-0237 LVP Advanced Evaluated parameters: Taulog, Time to peak, Relaxation time RT50 and RT10, Contractility Index
73-2715 Monophasic Action Potential 
Calculates: MaxV, MinV, Amplitude, Rate, dV/dtmax, dV/dtmin, APD90 (duration at 10% of MAP amplitude), APD75, APD50, APD25, APDx 

The software can also control our Programmable stimulator modules, requires 73-0224 software module for PSM control and the necessary PSM hardware 

Specifications

Commonly Used Signals for Langendorff Preparation are:

LVP    Isovolumetric LVP or contraction force
 PP    Perfusion pressure
 CF    Coronory flow
 WT    Wall thickness or left ventricle diameter
 EG
 Electrogram
 pO2a/e
   Oxygen partial pressure in the affluent / effluent
 pH
   pH in the effluent 


Commonly Used Signals for Working Heart Preparation are:

PrP    Preload pressure
 AoP   Aortic pressure (afterload)
 LVP
  Left Ventricular Pressure, measured with tip catheter
 AF
  Aortic flow
 CO
  Cardiac output (flow into left atrium)
 WT
  Wall thickness or left ventricle diameter
 EG
  Electrogram
 pO2a/e
  Oxygen partial pressure in the affluent / effluent
 pH   pH in the effluent


It is also possible to acquire other signals (e.g., temperature); maximum is 8 or 16 signals depending on hardware used.