IPL-4 Custom-Configured Isolated Perfused Lung System for Rabbit to Fetal Pig

IPL-4 Custom-Configured Isolated Perfused Lung System for Rabbit to Fetal Pig

The IPL-4 Isolated Perfused Lung System can be customized by modifying the Core System or configuring a complete system to meet your specific needs.

The Core System can be easily upgraded to add capabilities for virtually any ex-vivo pulmonary assay with additions, for example, for a nebulizer or deoxygenation unit.

For questions, to add options, or for help with a custom configuration, please contact Technical Services at 800-547-6766 or via email.

Item# Description U.S. List Price Quantity
73-9906 IPL-4 Custom-Configured Isolated Perfused Lung System for Rabbit to Fetal Pig
Login for U.S. Pricing

Applications

  • Investigation of ventilation and perfusion in the isolated rabbit or fetal pig lung

  • Optimized in-situ preparation

  • Negative-pressure ventilation to mimic closely the in-vivo situation

  • Regular induction of hyperinflation of the lung (sigh)

  • Perfusion under constant flow condition using buffer solution or blood

  • Continuous measurement of lung mechanics (tidal volume, resistance, compliance), and perfusate characteristics (pressure, pCO2, pO2, pH)

  • Continuous measurement of lung weight changes (edema)

Ventilation

When the lung is placed in the artificial thoracic chamber and ventilated at negative pressure, the ventilation head is removed and replaced by the pneumotachometer for the measurement of respiratory flow. The ventilation medium (air or gas mixture) is constantly flowing past the distal end of the pneumotachometer. The breathing frequency can be varied between 30 and 60 breaths/min. In addition, the inspiratory time as a percentage of each breath, can be set between 10 and 90% in 10% steps. The end-inspiratory, end-expiratory, and deep breath (hyperinflationary) negative pressure can be set individually. A deep breath is usually induced every 5 to 20 min.

Constant Flow Perfusion

The constant flow rate of perfusate into the pulmonary artery is determined by a roller pump. The perfusate is stored in a water-jacketed container to maintain constant temperature. Aeration is provided to keep the pH constant. A heat exchanger and a bubble trap are placed next to the pulmonary artery connection for exact adjustment of the perfusate temperature just before the thorax chamber and to prevent air bubbles entering the lung.
Different perfusates can be provided in turn by transferring the suction tube from one reservoir to another; there is no need for prior aeration or temperature control. The use of oxygen-sensitive test substances raises few problems since the contact time with the high oxygen concentration is minimized. It is also possible to vary the gas mixture rapidly during the study.  A Constant Pressure Perfusion System is optionally available. Please call for details.

Lung Mechanics

The pressure inside the thoracic chamber is measured with a MPX pressure transducer. Air flow is determined with the pneumotachometer connected to a Validyne differential pressure transducer DP 45-14. The volume is derived from the air flow by integration. The calculation of pulmonary compliance and resistance needs a computer controlled data acquisition system (HSE-HA Pulmodyn).

Specifications