IPL-2 Core System 230 V 73-4275

IPL-2 Core System 230 V  73-4275

CORE SYSTEM FOR THE ISOLATED PERFUSED LUNG SIZE 2 (IPL-2), 230V VERSION

Item# Description U.S. List Price Quantity
73-2266 BASIC UNIT FOR THE ISOLATED PERFUSED LUNG SIZE 2 (IL2) TYPE 829/2
73-0125 THERMOSTATIC CIRCULATOR E 103, BATH VOLUME 3 L, 230 V/50 Hz
73-3440 RESERVOIR JACKETED FOR BUFFER SOLUTION, WITH FRIT, 2L
73-3456 Tube Set for Jacketed Buffer Reservoir with Fluid Line Shutoff Valves
73-0114 ISM 827/230V ROLLER PUMP REGLO ANALOGUE, 4 CHANNELS, 0.003 - 35 ML/MIN
73-0155 3-Stop Tygon® E-Lab Tubing, 2.79 mm ID, 12/pack, Purple/White
73-1839 3-Stop Tygon® E-Lab Tubing, 3.17 mm ID, 12/pack, Black/White
73-0045 PLUGSYS Case, Type 603
73-0020 Blood Pressure Transducer P75 for PLUGSYS Module
73-1793 Transducer Amplifier Module (TAM-D)
73-2806 Servo Controller for Perfusion (SCP) Type 704, 73-2806
73-3882 DIFFERENTIAL LOW PRESSURE TRANSDUCER DLP2.5, RANGE +- 2.5 cmH2O, HSE CONNECTOR
73-0065 Transducer Amplifier Module (TAM-A)
73-0064 DIFFERENTIAL PRESSURE TRANSDUCER MPX, TYPE 399/2, RANGE +- 100 cm H2O, HSE CONNECTOR
73-2488 OP. TABLE SIZE 5 FOR IPL 2
Login for U.S. Pricing

MEASURED SIGNALS & PARAMETERS ON AN IPL-2 BASIC SYSTEM:

The Following Signals are Recorded as Raw Data:


  • Pulmonary Artery (Perfusion) Pressure
  • Intrapleural (artificial thorax) Pressure or Tracheal Pressure
  • Respiratory Flow

The Following Parameters can be calculated from the Raw Data:


  • Tidal Volume, Minute Volume
  • Respiratory Volume
  • Peak Inspiratory and Expiratory Airflow
  • Vascular Resistance
  • Respiration Rate
  • Inspiratory Time & Expiratory Time
  • End Inspiratory and Expiratory Pressure
  • Dynamic Airway Resistance & Compliance

* Calculations are automatic when HSE PULMODYN software is used.

Features & Benefits

  • Optimized temperature conditions for the isolated lung, unique jacketed thoracic chamber
  • Operating table for non-damaging in-situ preparation
  • Negative-pressure ventilation similar to in-vivo condition or positive-pressure ventilation available
  • Low flow resistance and dead space volume, minimize perfusion artifacts
  • Unique built-in pneumotachometer and air humidifier with small dead volume
  • Drug injection pathway built directly into pulmonary perfusate stream
  • Unique compensation system for vascular transmural pressure changes
  • Dedicated option for continuous measurement of lung weight (edema)
  • More measurement parameters than any other system
Specifications73-011473-015573-183973-004573-179373-280673-006573-0064
ApplicationSpeed Control 0 - 5 V or 0 - 10 V and 0 - 20 mA respectivelyPurple-WhiteBlack-WhiteLine Cable, Spare Fuses, Screw driver for fitting Function Modules, Document Folder for Operating Instructions of Function Modules, 3 x BNC-BNC Output linesTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayOperating Instructions, Screwdriver, Output Cable to PumpTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayOnly for dry air
Depth English1.0 bar (14.5 PSI)Tygon® E-LabTygon® E-Lab5.2 x 19 x 17.1 inThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)0 - 10 V via System BusThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)1.4
Depth Metric5.6 x 3.9 x 7.6 in2.79 mm3.17 mm132 x 483 x 435 mm+5V / 50 mA max.Laboratory Indoors+5V / 50 mA max.36
Excitation Voltage143 x 100 x 190 mmMetallic housing, gray plastic coated, Universal 19 inch case with pivoting feet, prepared for rack mountingSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
DIN 41612, 96-pin VGSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
0 to 5 VDC or AC
Height EnglishRotation direction, Start/Stop20 slot units max.Selectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn TrimmerPlug-in Module for a PLUGSYSSelectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn Trimmer0.9
Height Metric115 V / 50 Hz or 230 V / 50 Hz100 to 240 VAC, 50/60 Hz, built-in line filter, 100 W max. consumptiona) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
1 - 50, Adjustablea) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
24
Inlet/Outlet Nozzel ID Metric35 ml/min3-pin IEC mains with fuse and mains switch on back of housing2 slot units0 - 10 V to Operate the Pump2 slot units2
Inlet/Outlet Nozzel Length Metric0.002 ml/min14.3 lbs+5V through connector from PLUGSYS bus system0.1 - 100, Adjustable+5V through connector from PLUGSYS bus system9
Inlet/Outlet Nozzel OD Metric46.5 kga) On front panel through BNC socket Servo Controller for Perfusion (SCP) Type 704a) On front panel through BNC socket 4.7
Input Resistance86-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?Range -1999 to +1999, Selectable for Actual Value, Setpoint, or Control Output Signal6-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?400 to 550
Linearity20 WElectronic PID Controller for Physiological and Pharmacological Research
Offset VoltageIP 300.05 - 10, Adjustable1 mV maximum
Output Resistanceyes2 slot units600 to 1000
Overpressure EnglishMS-4/8-1005 V, 0.3 A from PLUGSYS750
Overpressure Metric1 to 100 rpm0 - 10 V, BNC Socket
Pressure RangesAdjustable in 1% steps (0-99%)0 - 5 V, Adjustable
Sensitivity3 to 99%, resolution 1%, 2 digit potentiometer0.3 kg0.3 to 0.8 mV/Bar