IPL-16 Core System 230 V 73-4301

IPL-16 Core System 230 V 73-4301

IPL-16 Core System 230 V 73-4301

Item# Description U.S. List Price Quantity
73-4109 BASIC UNIT FOR ISOLATED PERFUSED PIG LUNG SIZE 16 TYPE 869/3 (IL-16)
73-0125 THERMOSTATIC CIRCULATOR E 103, BATH VOLUME 3 L, 230 V/50 Hz
73-3028 ISM 444/230 V PUMP DRIVE BVP
73-3120 ISM 791 PRO-380, 3 ROLLER, FOR 1.6 MM WT
72-4621 Tygon® E-3603 Tubing, 15.2 m (50 ft) Length, 9.5 mm (3/8 in) ID, 12.7 mm (1/2 in) OD
73-0045 PLUGSYS Case, Type 603
73-0020 Blood Pressure Transducer P75 for PLUGSYS Module
73-1793 Transducer Amplifier Module (TAM-D)
73-2806 Servo Controller for Perfusion (SCP) Type 704, 73-2806
72-6310 HEATED PNEUMOTACHOMETER FOR LARGE DOG WITH SIDE PORT
59-9703 Heater Controller for Single Pneumotachometer 230 VAC, 50 Hz
73-3882 DIFFERENTIAL LOW PRESSURE TRANSDUCER DLP2.5, RANGE +- 2.5 cmH2O, HSE CONNECTOR
73-0065 Transducer Amplifier Module (TAM-A)
73-0064 DIFFERENTIAL PRESSURE TRANSDUCER MPX, TYPE 399/2, RANGE +- 100 cm H2O, HSE CONNECTOR
Login for U.S. Pricing
CORE SYSTEM FOR THE ISOLATED PERFUSED LUNG SIZE 16 (IPL-16), 230V VERSION
Specifications73-302873-312072-462173-004573-002073-179373-280673-006573-0064
ApplicationSpeed control 0-5 V or 0-10 V respectively 0-20 mA or 4-20 mA0.45 to 3400 ml/min3/8Line Cable, Spare Fuses, Screw driver for fitting Function Modules, Document Folder for Operating Instructions of Function Modules, 3 x BNC-BNC Output linesCETAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayOperating Instructions, Screwdriver, Output Cable to PumpTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayOnly for dry air
Depth English1.5 bar (22 PSI)19.505.2 x 19 x 17.1 in4.9 ftThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)0 - 10 V via System BusThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)1.4
Depth Metric9.8 x 6.1 x 8.7 in350132 x 483 x 435 mm14.5 m+5V / 50 mA max.Laboratory Indoors+5V / 50 mA max.36
Excitation Voltage260 x 155 x 220 mmPro-38015.2Metallic housing, gray plastic coated, Universal 19 inch case with pivoting feet, prepared for rack mounting15 mA max.Selectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
DIN 41612, 96-pin VGSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
0 to 5 VDC or AC
Height EnglishFlow direction, start/stop1.6 mmTygon20 slot units max.0 to 100 HzSelectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn TrimmerPlug-in Module for a PLUGSYSSelectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn Trimmer0.9
DOCUMENT DESCRIPTION
bvp_blood_pump_e.pdfPump Drive BVP-BP for Centrifugal Blood Pump Heads Manual