IPL-1 Core System 73-4292, 115 V

IPL-1 Core System 73-4292, 115 V

IPL-1 Core System 73-4292, 115 V

Item# Description U.S. List Price Quantity
73-2329 BASIC UNIT FOR ISOLATED PERFUSED LUNG SIZE 1 TYPE 839 (MOUSE)
73-2802 THERMOSTATIC CIRCULATOR E 103, BATH VOLUME 3 L, 115 V/60 Hz
73-3436 RESERVOIR JACKETED FOR BUFFER SOLUTION, WITH FRIT, 0.5L
73-3456 Tube Set for Jacketed Buffer Reservoir with Fluid Line Shutoff Valves
73-0113 ISM 827/115V ROLLER PUMP REGLO ANALOGUE, 4 CHANNELS, 0.002 - 30 ML/MIN
73-1825 3-Stop Tygon® E-Lab Tubing, 0.89 mm ID, 12/pack, Orange/Orange
73-0126 3-Stop Tygon® E-Lab Tubing, 1.22 mm ID, 12/pack, Red/Grey
73-0500 Lab Stand with Triangular Base Plate (one block clamp included)
73-0566 Plexiglass Block Clamp - for mounting 73-4337 Bar onto Lab Stand
73-0045 PLUGSYS Case, Type 603
73-0020 Blood Pressure Transducer P75 for PLUGSYS Module
73-1793 Transducer Amplifier Module (TAM-D)
73-2806 Servo Controller for Perfusion (SCP) Type 704, 73-2806
73-3882 DIFFERENTIAL LOW PRESSURE TRANSDUCER DLP2.5, RANGE +- 2.5 cmH2O, HSE CONNECTOR
73-0065 Transducer Amplifier Module (TAM-A)
73-0064 DIFFERENTIAL PRESSURE TRANSDUCER MPX, TYPE 399/2, RANGE +- 100 cm H2O, HSE CONNECTOR
Login for U.S. Pricing
CORE SYSTEM FOR THE ISOLATED PERFUSED MOUSE LUNG SIZE 1 (IPL-1), 115V VERSION
Specifications73-011373-182573-012673-004573-179373-280673-006573-0064
ApplicationSpeed Control 0 - 5 V or 0 - 10 V and 0 - 20 mA respectivelyOrange-OrangeRed-GreyLine Cable, Spare Fuses, Screw driver for fitting Function Modules, Document Folder for Operating Instructions of Function Modules, 3 x BNC-BNC Output linesTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayOperating Instructions, Screwdriver, Output Cable to PumpTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayOnly for dry air
Depth English1.0 bar (14.5 PSI)Tygon® E-LabTygon® E-Lab5.2 x 19 x 17.1 inThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)0 - 10 V via System BusThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)1.4
Depth Metric5.6 x 3.9 x 7 in0.89 mm1.22 mm132 x 483 x 435 mm+5V / 50 mA max.Laboratory Indoors+5V / 50 mA max.36
Excitation Voltage143 x 100 x 178 mmMetallic housing, gray plastic coated, Universal 19 inch case with pivoting feet, prepared for rack mountingSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
DIN 41612, 96-pin VGSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
0 to 5 VDC or AC
Height EnglishRotation direction, Start/Stop20 slot units max.Selectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn TrimmerPlug-in Module for a PLUGSYSSelectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn Trimmer0.9
Height Metric115 V / 50 Hz or 230 V / 50 Hz100 to 240 VAC, 50/60 Hz, built-in line filter, 100 W max. consumptiona) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
1 - 50, Adjustablea) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
24
Inlet/Outlet Nozzel ID Metric35 ml/min3-pin IEC mains with fuse and mains switch on back of housing2 slot units0 - 10 V to Operate the Pump2 slot units2
Inlet/Outlet Nozzel Length Metric0.002 ml/min14.3 lbs+5V through connector from PLUGSYS bus system0.1 - 100, Adjustable+5V through connector from PLUGSYS bus system9
Inlet/Outlet Nozzel OD Metric46.5 kga) On front panel through BNC socket Servo Controller for Perfusion (SCP) Type 704a) On front panel through BNC socket 4.7
Input Resistance86-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?Range -1999 to +1999, Selectable for Actual Value, Setpoint, or Control Output Signal6-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?400 to 550
Linearity20 WElectronic PID Controller for Physiological and Pharmacological Research
Offset VoltageIP 300.05 - 10, Adjustable1 mV maximum
Output Resistanceyes2 slot units600 to 1000
Overpressure EnglishMS-4/8-1005 V, 0.3 A from PLUGSYS750
Overpressure Metric1 to 100 rpm0 - 10 V, BNC Socket
Pressure RangesAdjustable in 1% steps (0-99%)0 - 5 V, Adjustable
Sensitivity3 to 99%, resolution 1%, 2 digit potentiometer0.3 kg0.3 to 0.8 mV/Bar

Kentaro Nodaa,b, Norihisa Shigemuraa,*, Yugo Tanakaa, Jay K. Bhamaa, Jonathan D'Cunhaa, James D. Luketicha and Christian A. Bermudeza (2014 ) Successful prolonged ex vivo lung perfusion for graft preservation in rats Eur J Cardiothorac Surg

Hannah T. Nickles , Migle Sumkauskaite , Xin Wang , Ingmar Wegner , Michael Puderbach , Wolfgang M. Kuebler (2014 ) Mechanical ventilation causes airway distension with proinflammatory sequelae in mice Am J Physiolo Lung Cell Mol Physiol

Yan-ling Wang,1 Jing-hui Chen,2 Qiong-fang Zhu,3 Gao-feng Yu,2 Chen-fang Luo,1 Gang-jian Luo,1 Shang-rong Li,1 and Zi-qing Hei1 (2015 ) In Vivo Evaluation of the Ameliorating Effects of Small-Volume Resuscitation with Four Different Fluids on Endotoxemia-Induced Kidney Injury Mediators Inflamm

Kentaro Nodaa,b, Norihisa Shigemuraa,*, Yugo Tanakaa, Jay K. Bhamaa, Jonathan D'Cunhaa, James D. Luketicha and Christian A. Bermudeza (2014 ) Successful prolonged ex vivo lung perfusion for graft preservation in rats Eur J Cardiothorac Surg

Christoph Curths*†‡1, Judy Wichmann*†‡1, Sarah Dunker*†, Horst Windt†§, Heinz‑Gerd Hoymann*†, Hans D. Lauenstein*†, Jens Hohlfeld*†, Tamara Becker‡, Franz‑Josef Kaup‡, Armin Braun*†∥ and Sascha Knauf*†‡ (2014 ) Airway hyper-responsiveness in lipopolysaccharide-challenged common marmosets (Callithrix jacchus) Clin Sci (Lond)

Robert Huhlea*, Peter M. Spietha, Andreas Güldnera, Thea Kocha & Marcelo Gama de Abreua (2014 ) " A new adaptive controller for volume-controlled mechanical ventilation in small animals" Exp Lung Res