IPL-1 Core System 73-4291 230 V

IPL-1 Core System 73-4291 230 V

IPL-1 Core System 73-4291 230 V

Item# Description U.S. List Price Quantity
73-2329 BASIC UNIT FOR ISOLATED PERFUSED LUNG SIZE 1 TYPE 839 (MOUSE)
73-0125 THERMOSTATIC CIRCULATOR E 103, BATH VOLUME 3 L, 230 V/50 Hz
73-3456 Tube Set for Jacketed Buffer Reservoir with Fluid Line Shutoff Valves
73-0114 ISM 827/230V ROLLER PUMP REGLO ANALOGUE, 4 CHANNELS, 0.003 - 35 ML/MIN
73-1825 3-Stop Tygon® E-Lab Tubing, 0.89 mm ID, 12/pack, Orange/Orange
73-0126 3-Stop Tygon® E-Lab Tubing, 1.22 mm ID, 12/pack, Red/Grey
73-0500 Lab Stand with Triangular Base Plate (one block clamp included)
73-0566 Plexiglass Block Clamp - for mounting 73-4337 Bar onto Lab Stand
73-0045 PLUGSYS Case, Type 603
73-0020 Blood Pressure Transducer P75 for PLUGSYS Module
73-1793 Transducer Amplifier Module (TAM-D)
73-2806 Servo Controller for Perfusion (SCP) Type 704, 73-2806
73-3882 DIFFERENTIAL LOW PRESSURE TRANSDUCER DLP2.5, RANGE +- 2.5 cmH2O, HSE CONNECTOR
73-0064 DIFFERENTIAL PRESSURE TRANSDUCER MPX, TYPE 399/2, RANGE +- 100 cm H2O, HSE CONNECTOR
73-0065 Transducer Amplifier Module (TAM-A)
Login for U.S. Pricing

MEASURED SIGNALS & PARAMETERS ON AN IPL-1 BASIC SYSTEM:

The Following Signals are Recorded as Raw Data:

  • Pulmonary Artery (Perfusion) Pressure
  • Perfusion Flow
  • Intrapleural (artificial thorax) Pressure or Tracheal Pressure
  • Respiratory Flow

The Following Parameters can be calculated from the Raw Data:

  • Tidal Volume, Minute Volume
  • Respiratory Volume
  • Peak Inspiratory & Expiratory Airflow
  • Vascular Resistance
  • Respiration Rate
  • Inspiratory Time & Expiratory Time
  • End Inspiratory & Expiratory Pressure
  • Dynamic Airway Resistance & Compliance * Calculations are automatic when HSE PULMODYN software is used.

FEATURES & BENEFITS

  • Exclusive artificial thorax chamber for isolated lung with integrated changeover system for switch between simple positive-pressure ventilation and physiological negative (subatmospheric pressure ventilation)
  • Integrated surgery table to reduce damage during preparation
  • Unique built-in pneumotachometer and air humidifier with small dead volume
  • Drug injection pathway built directly into pulmonary perfusate stream
  • Low flow resistance and dead space volume minimize perfusion artifacts
  • Proprietary cannulae are matched to mouse vessel and feature tip occlusion protectors and Mini Ball system which allow cannulae to be fixed, further reducing the incidence of vascular occlusion
Specifications73-011473-182573-012673-004573-179373-280673-006473-0065
Analog IndicationSpeed Control 0 - 5 V or 0 - 10 V and 0 - 20 mA respectivelyOrange-OrangeRed-GreyLine Cable, Spare Fuses, Screw driver for fitting Function Modules, Document Folder for Operating Instructions of Function Modules, 3 x BNC-BNC Output linesTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayOperating Instructions, Screwdriver, Output Cable to PumpOnly for dry airTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED display
Bridge Balance1.0 bar (14.5 PSI)Tygon® E-LabTygon® E-Lab5.2 x 19 x 17.1 inThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)0 - 10 V via System Bus1.4Through 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)
Bridge Supply Voltage5.6 x 3.9 x 7.6 in0.89 mm1.22 mm132 x 483 x 435 mm+5V / 50 mA max.Laboratory Indoors36+5V / 50 mA max.
Electrical Calibration143 x 100 x 190 mmMetallic housing, gray plastic coated, Universal 19 inch case with pivoting feet, prepared for rack mountingSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
DIN 41612, 96-pin VG0 to 5 VDC or ACSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
GainRotation direction, Start/Stop20 slot units max.Selectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn TrimmerPlug-in Module for a PLUGSYS0.9Selectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn Trimmer
Output Low-Pass Filter115 V / 50 Hz or 230 V / 50 Hz100 to 240 VAC, 50/60 Hz, built-in line filter, 100 W max. consumptiona) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
1 - 50, Adjustable24a) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
PLUGSYS Width*35 ml/min3-pin IEC mains with fuse and mains switch on back of housing2 slot units0 - 10 V to Operate the Pump22 slot units
Power Supply0.002 ml/min14.3 lbs+5V through connector from PLUGSYS bus system0.1 - 100, Adjustable9+5V through connector from PLUGSYS bus system
Signal Output46.5 kga) On front panel through BNC socket Servo Controller for Perfusion (SCP) Type 7044.7a) On front panel through BNC socket
Transducer Input86-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?Range -1999 to +1999, Selectable for Actual Value, Setpoint, or Control Output Signal400 to 5506-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?
20 WElectronic PID Controller for Physiological and Pharmacological Research
IP 300.05 - 10, Adjustable1 mV maximum
yes2 slot units600 to 1000
MS-4/8-1005 V, 0.3 A from PLUGSYS750
1 to 100 rpm0 - 10 V, BNC Socket
Adjustable in 1% steps (0-99%)0 - 5 V, Adjustable
3 to 99%, resolution 1%, 2 digit potentiometer0.3 kg0.3 to 0.8 mV/Bar