IPL-1 Core System 73-4291 230 V

IPL-1 Core System 73-4291 230 V

IPL-1 Core System 73-4291 230 V

Item# Description U.S. List Price Quantity
73-2329 BASIC UNIT FOR ISOLATED PERFUSED LUNG SIZE 1 TYPE 839 (MOUSE)
73-0125 THERMOSTATIC CIRCULATOR E 103, BATH VOLUME 3 L, 230 V/50 Hz
73-3456 Tube Set for Jacketed Buffer Reservoir with Fluid Line Shutoff Valves
73-0114 ISM 827/230V ROLLER PUMP REGLO ANALOGUE, 4 CHANNELS, 0.003 - 35 ML/MIN
73-1825 3-Stop Tygon® E-Lab Tubing, 0.89 mm ID, 12/pack, Orange/Orange
73-0126 3-Stop Tygon® E-Lab Tubing, 1.22 mm ID, 12/pack, Red/Grey
73-0500 Lab Stand with Triangular Base Plate (one block clamp included)
73-0566 Plexiglass Block Clamp - for mounting 73-4337 Bar onto Lab Stand
73-0045 PLUGSYS Case, Type 603
73-0020 Blood Pressure Transducer P75 for PLUGSYS Module
73-1793 Transducer Amplifier Module (TAM-D)
73-2806 Servo Controller for Perfusion (SCP) Type 704, 73-2806
73-3882 DIFFERENTIAL LOW PRESSURE TRANSDUCER DLP2.5, RANGE +- 2.5 cmH2O, HSE CONNECTOR
73-0064 DIFFERENTIAL PRESSURE TRANSDUCER MPX, TYPE 399/2, RANGE +- 100 cm H2O, HSE CONNECTOR
73-0065 Transducer Amplifier Module (TAM-A)
Login for U.S. Pricing

MEASURED SIGNALS & PARAMETERS ON AN IPL-1 BASIC SYSTEM:

The Following Signals are Recorded as Raw Data:

  • Pulmonary Artery (Perfusion) Pressure
  • Perfusion Flow
  • Intrapleural (artificial thorax) Pressure or Tracheal Pressure
  • Respiratory Flow

The Following Parameters can be calculated from the Raw Data:

  • Tidal Volume, Minute Volume
  • Respiratory Volume
  • Peak Inspiratory & Expiratory Airflow
  • Vascular Resistance
  • Respiration Rate
  • Inspiratory Time & Expiratory Time
  • End Inspiratory & Expiratory Pressure
  • Dynamic Airway Resistance & Compliance * Calculations are automatic when HSE PULMODYN software is used.

FEATURES & BENEFITS

  • Exclusive artificial thorax chamber for isolated lung with integrated changeover system for switch between simple positive-pressure ventilation and physiological negative (subatmospheric pressure ventilation)
  • Integrated surgery table to reduce damage during preparation
  • Unique built-in pneumotachometer and air humidifier with small dead volume
  • Drug injection pathway built directly into pulmonary perfusate stream
  • Low flow resistance and dead space volume minimize perfusion artifacts
  • Proprietary cannulae are matched to mouse vessel and feature tip occlusion protectors and Mini Ball system which allow cannulae to be fixed, further reducing the incidence of vascular occlusion
Specifications73-011473-182573-012673-004573-002073-179373-280673-006473-0065
Analog IndicationSpeed Control 0 - 5 V or 0 - 10 V and 0 - 20 mA respectivelyOrange-OrangeRed-GreyLine Cable, Spare Fuses, Screw driver for fitting Function Modules, Document Folder for Operating Instructions of Function Modules, 3 x BNC-BNC Output linesCETAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayOperating Instructions, Screwdriver, Output Cable to PumpOnly for dry airTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED display
Bridge Balance1.0 bar (14.5 PSI)Tygon® E-LabTygon® E-Lab5.2 x 19 x 17.1 in4.9 ftThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)0 - 10 V via System Bus1.4Through 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)
Bridge Supply Voltage5.6 x 3.9 x 7.6 in0.89 mm1.22 mm132 x 483 x 435 mm14.5 m+5V / 50 mA max.Laboratory Indoors36+5V / 50 mA max.
Electrical Calibration143 x 100 x 190 mmMetallic housing, gray plastic coated, Universal 19 inch case with pivoting feet, prepared for rack mounting15 mA max.Selectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
DIN 41612, 96-pin VG0 to 5 VDC or ACSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
GainRotation direction, Start/Stop20 slot units max.0 to 100 HzSelectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn TrimmerPlug-in Module for a PLUGSYS0.9Selectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn Trimmer
Output Low-Pass Filter115 V / 50 Hz or 230 V / 50 Hz100 to 240 VAC, 50/60 Hz, built-in line filter, 100 W max. consumption±0.15 mmHga) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
1 - 50, Adjustable24a) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
PLUGSYS Width*35 ml/min3-pin IEC mains with fuse and mains switch on back of housing±0.04 mmHg2 slot units0 - 10 V to Operate the Pump22 slot units
Power Supply0.002 ml/min14.3 lbsAll gases and liquids which do not attack Macrolon®+5V through connector from PLUGSYS bus system0.1 - 100, Adjustable9+5V through connector from PLUGSYS bus system
Signal Output46.5 kg2.76 ina) On front panel through BNC socket Servo Controller for Perfusion (SCP) Type 7044.7a) On front panel through BNC socket
Transducer Input870 mm6-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?Range -1999 to +1999, Selectable for Actual Value, Setpoint, or Control Output Signal400 to 5506-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?
20 W0.31 inElectronic PID Controller for Physiological and Pharmacological Research
IP 308 mm0.05 - 10, Adjustable1 mV maximum
yes300 Ω, nominal2 slot units600 to 1000
MS-4/8-100?760 (= vacuum) to 4,000 mmHg5 V, 0.3 A from PLUGSYS750
1 to 100 rpmLuer taper, male0 - 10 V, BNC Socket
Adjustable in 1% steps (0-99%)±75 mmHg0 - 5 V, Adjustable
3 to 99%, resolution 1%, 2 digit potentiometer±0.04 mV/10°C (±0.04 mmHg/10°C) (0° to 50°C)0.3 kg0.3 to 0.8 mV/Bar