IH-ENDO-MAP MEASUREMENT OF ONE ENDOCARDIAL MAP ON RAT, GUINEA PIG OR RABBIT, 73-4027

IH-ENDO-MAP MEASUREMENT OF ONE ENDOCARDIAL  MAP  ON  RAT, GUINEA PIG OR RABBIT, 73-4027

IH-ENDO-MAP MEASUREMENT OF ONE ENDOCARDIAL MAP ON RAT, GUINEA PIG OR RABBIT , 73-4027

Item# Description U.S. List Price Quantity
73-3715 MAP ELECTRODE FOR INTRACARDIAL MAP, STRAIGHT
73-0152 CONNECTION CABLE FOR MAP ELECTRODE TO BPA
73-0153 Biopotential Amplifier Module (BPA)
Login for U.S. Pricing

IH-ENDO-MAP MEASUREMENT OF ONE ENDOCARDIAL  MAP  ON  RAT, GUINEA PIG OR RABBIT, 73-4027

 

Compatible with both IH-SR and IH-5 Core Systems

Specifications73-0153
Analog IndicationThrough LED bar graph +13/-7 LEDs for monitoring applied signal; display sensitivity can be changed by key from +10/-5V to +1/-0.5V
Auto ZeroAutomatic zero adjustment by pressing key
ConnectorDIN 41612 96-pin VG (PLUGSYS system bus)
Electrical CalibrationCAL automatic calibration steps operated by zero key, for transducer calibration and evaluation of input signal; calibration voltage 0.3, 1, 3, 10, 30, 100 mV is changed automatically to suit amplification setting
Filter IndicationSettings of high-pass and low-pass filters are indicated as frequency pass band using LED line on front panel
Frequency RangeDC to 10kHz (-3 dB)
Gain20x, 100x, 200x, 1000x, 2000x and 10,000x selected by switch, can be varied by multi-turn trimmer within range of 10 to 100% (based on current amplification setting)
High-Pass Filter12 settings, range 0.03 Hz to 10 kHz (-3 dB)
InputDirect for biological signals (ECG, EMG, EEG, ENG) and for strain gauge bridge transducers
Input Bias Current30 nA maximum
Input Capacity1.5 nF
Input ImpedanceHigher than 100 M?
Low-Pass Filter10 settings, range DC to 100 Hz (-3 dB)
Manual ZeroManual zero adjustment for correcting high input offset voltages which exceed automatic adjustment range of Auto Zero
Notch Filter(HUM-ELIMINATION) to suppress 50 (60) Hz interference
PLUGSYS Width*2 slot units
Power Supply5 V 1.2 A from PLUGSYS system bus
Quick StartRapid discharge of coupling capacitors by pressing key
Signal Input8-pin binder (Amphenol) socket with screw lock
Signal Output1. Internally through system bus of PLUGSYS measuring system; signal output is assigned to connecting lines AV-1 to AV-16 through jumper
2. On front panel through BNC socket
Transducer Supply5 V a bridge supply for transducers and supply for headstages
  • Mini monophasic action potential electrode for endocardial with dedicated holders
  • Dedicated holders allow easy positioning on the heart