H5-WH 230 V WORKING HEART OPTION TO IH-5 CORE SYSTEM 73-4412

H5-WH  230 V WORKING HEART OPTION TO IH-5 CORE SYSTEM 73-4412

H5-WH 230 V WORKING HEART OPTION TO IH-5 CORE SYSTEM 73-4412

Item# Description U.S. List Price Quantity
73-3064 WORKING HEART OPTION TO BASIC UNIT TYPE 843 (IH-5)
73-0116 MCP-SB2/230V ROLLER PUMP, 2 CHANNELS, EACH 2-1100 ML/MIN
73-0065 Transducer Amplifier Module (TAM-A)
73-0020 Blood Pressure Transducer P75 for PLUGSYS Module
Login for U.S. Pricing

H5-WH 230 V WORKING HEART OPTION TO IH-5 CORE SYSTEM 73-4412

The Working Heart option must be paired with the system configuration  “Langendorff Working Heart-Ready Configuration.” If you are upgrading
from a Working Heart-Ready configuration or are building a Working Heart System from scratch, then simply add the
Working Heart Option and one or both of the species-specific options below.

Includes:

  • Left Atrial Cannulating System

° Preload Reservoir (2-7 mL capacity)
° Movable Atrium Connection Adapter
° Holder for Preload Pressure Transducer

  • Peristaltic Pump with Tubing
  • Preload Pressure Measurement

° Venous Pressure Transducer
° TAM-A Amplifier

Utilizes 2 Slot Units

Specifications73-006573-0020
CertificationsTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayCE
Connection Cable Length EnglishThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)4.9 ft
Connection Cable Length Metric+5V / 50 mA max.14.5 m
Current LoadingSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
15 mA max.
Frequency RangeSelectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn Trimmer0 to 100 Hz
Linearitya) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
±0.15 mmHg
Long Term Drift2 slot units±0.04 mmHg
Measurement Media+5V through connector from PLUGSYS bus systemAll gases and liquids which do not attack Macrolon®
Mounting Rod Length Englisha) On front panel through BNC socket 2.76 in
Mounting Rod Length Metric6-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?70 mm