Gel Filtration Packing Material Macro SpinColumns

Gel Filtration Packing Material Macro SpinColumns

Macro SpinColumns are best suited for samples with volumes from 75 to 150 µl. In addition to the standard packing materials described in the ordering information, Macro SpinColumns can be filled with custom packing materials as desired. Each column includes two 2 ml centrifuge tubes and top and bottom caps.

Item# Description U.S. List Price Quantity
74-4303 Macro SpinColumns, P-6 (Polyacrylamide-based gel filtration) Packing Material, Qty. of 96
74-4309 Macro SpinColumns, P-6 (Polyacrylamide-based gel filtration) Packing Material, Qty. of 24
74-4302 Macro SpinColumns, P-2 (Polyacrylamide-based gel filtration) Packing Material, Qty. of 96
74-4308 Macro SpinColumns, P-2 (Polyacrylamide-based gel filtration) Packing Material, Qty. of 24
74-3903 Macro SpinColumns, G-100 Packing Material, Qty. of 96
74-3907 Macro SpinColumns, G-100 Packing Material, Qty. of 24
74-3902 Macro SpinColumns, G-50 Packing Material, Qty. of 96
74-3906 Macro SpinColumns, G-50 Packing Material, Qty. of 24
74-3901 Macro SpinColumns, G-25 Packing Material, Qty. of 96
74-3905 Macro SpinColumns, G-25 Packing Material, Qty. of 24
74-3900 Macro SpinColumns, G-10 Packing Material, Qty. of 96
74-3904 Macro SpinColumns, G-10 Packing Material, Qty. of 24
Login for U.S. Pricing
Advantages:
• Easy to use
• Unrivaled selection of column packing materials
• High sample recovery
• Rapid sample preparation time
• Custom packed columns are available on request
Applications:
• DNA purification
• Protein purification
• Peptide purification
• Small molecule, carbohydrate removal
• Radiolabel removal
• Nick translation
• Affinity separation
• Salt removal
• Buffer exchange
Harvard Apparatus new generation of SpinColumns are designed for the purification of small samples (10 µl to 150 µl) in either single column or high-throughput 96-well format with a standard centrifuge.
Our SpinColumns are pre-filled with a wide selection of chromatographic materials including gel-filtration, ion-exchange, silica-based reverse- and normal-phase materials, as well as specific materials, such as charcoal or cellulose contained by frits and/or caps. The columns can also be pre-filled with custom materials based on customer requests.
Simply place the SpinColumn in a centrifuge tube and centrifuge the tube briefly to separate your sample. The column material binds and purifies the sample according to size and shape, chemical composition, charge or other physiochemical properties.
Harvard Apparatus offers four sizes of SpinColumns to fit your specific applications:
• Ultra-Micro SpinColumns
For sample volumes from 10 µl to 25 µl
• Micro SpinColumns
For sample volumes 25 µl to 75 µl
• Macro SpinColumns
For sample volumes from 75 µl to 150 µl
• 96-Well SpinColumns
For high throughput applications with sample volumes from 25 µl to 100 µl
Macro SpinColumns are best suited for samples with volumes from 75 to 150 µl. In addition to the standard packing materials described in the ordering information, Macro SpinColumns can be filled with custom packing materials as desired. Each column includes two 2 ml centrifuge tubes and top and bottom caps.
Specifications74-430374-430974-430274-430874-390374-390774-390274-390674-390174-390574-390074-3904
Packing MaterialP-6: Polyacrylamide-based Gel Filtration Packing MaterialP-6: Polyacrylamide-based Gel Filtration Packing MaterialP-2: Polyacrylamide-based Gel Filtration Packing MaterialP-2: Polyacrylamide-based Gel Filtration Packing MaterialG-100 Packing MaterialG-100 Packing MaterialG-50 Packing MaterialG-50 Packing MaterialG-25 Packing MaterialG-25 Packing MaterialG-10 Packing MaterialG-10 Packing Material
Sample Size Metric75 to 15075 to 15075 to 15075 to 15075 to 15075 to 15075 to 15075 to 15075 to 15075 to 15075 to 15075 to 150
Sample Size Metric UOMµlµlµlµlµlµlµlµlµlµlµlµl