Item# Description U.S. List Price Quantity
77-0112 Force Transducer (0-50 g) for use with Bridge Amps, Model MLT050/D
77-0131 Force Transducer (0-50 g) for use with Bridge Pod, Model MLT050/A
77-0120 Force Transducer (0-500 g) for use with Bridge Amps, Model MLT500/D
77-0128 Force Transducer (0-500 g) for use with Bridge Pod, Model MLT500/A
Login for U.S. Pricing
These units are low-cost, light-weight isometric transducers for detecting forces up to 50 g wt (MLT050 Models) or up to 500 g wt (MLT500 Models). MLT050/A and MLT500/A transducers are suitable for connection to the ML301 Bridge Pod, while MLT050/D and MLT500/D transducers are suitable for connection to any ADInstruments Bridge Amp. Operation: Force applied to the transducer causes a small deflection of a cantilever to which the strain-gauge is bonded. The strain-gauge elements change resistance in response to small changes in length. Two of the elements are aligned in the direction of strain, thus detecting force. The other two are used as reference elements, allowing for thermal compensation. If an excitation voltage is applied across one diagonal of this bridge circuit, a force results in a change in resistance and hence a change in signal voltage across the other diagonal. Application: The Force Transducer is suitable for measuring muscle contractions or similar forces.
Specifications77-011277-013177-012077-0128
Blade DisplacementSee product page for complete specifications±5 mmSee product page for complete specifications±5 mm
Body Dimensions L x W x H English±5 mm2.0 x 1.0 x 0.7 in±5 mm2.0 x 1.0 x 0.7 in
Body Dimensions L x W x H Metric2.0 x 1.0 x 0.7 in50 x 25 x 18 mm2.0 x 1.0 x 0.7 in50 x 25 x 18 mm
Bridge Resistance50 x 25 x 18 mm1000 Ω50 x 25 x 18 mm400 Ω
Cable Length English1000 Ω6.2 ft400 Ω6.2 ft
Cable Length Metric6.2 ft1.9 m6.2 ft1.9 m
Connector1.9 m8-pin DIN1.9 m8-pin DIN
Maximum Excitation8-pin DIN10 V DC8-pin DIN10 V DC
Model10 V DCMLT050/A10 V DCMLT500/A
Non linearity and HysteresisMLT050/D<0.5 % (full scale)MLT500/D<0.5 % (full scale)
Operating Range<0.5 % (full scale)0 to 50 g wt<0.5 % (full scale)0 to 500 g wt
Package0 to 50 g wt10 to 500 g wt1
Product Family1Data Acquisition1Data Acquisition
Resonant FrequencyData Acquisition450 Hz (minimum)Data Acquisition450 Hz (minimum)
Sensitivity450 Hz (minimum)(full range) 8.3 mV/V450 Hz (minimum)(full range) 3.3 mV/V
Support Rod Diameter Metric(full range) 8.3 mV/V0.3 in(full range) 3.3 mV/V0.3 in
Support Rod Length Metric0.3 in3.7 in0.3 in3.7 in
Warm Up Time3.7 in10 min3.7 in10 min
Weight10 min74 g10 min74 g