Extracorporal Inline Transonic Flow Probes 1 to 4 mm (N-Series)

Extracorporal Inline Transonic Flow Probes 1 to 4 mm (N-Series)

• Non-constrictive perivascular flowprobes
• For acute and chronic measurement of flow in arteries and veins
• large range of other vessel diameters from 500 æm to 36 mm
• Probes for micro-measurements in mice or rats
• Probes with Dual-beam "X"-Pattern for ascending aorta flow measurement
• Inline Flowprobes for extracorporal circuits (Isolated perfused organs)

In order to create an Inline Flowprobe for extracorporeal use, our engineers integrate the appropriate perivascular flowprobe into a block of clear Perspex using our proprietary process. The result is a robust flowprobe which can be spliced into standard laboratory tubing for virtually any application.Just as any flow probe we offer, the inline probes can be calibrated for use with blood, saline or buffer perfusates.

These Transonic Flow Probes work exclusively with the TTFM Transit Time Flow Meter (73-0146).

Item# Description U.S. List Price Quantity
73-4105 Extracorporal Inline Transonic Transit Time Flow Probe Type 4N
73-4104 Extracorporal Inline Transonic Transit Time Flow Probe Type 2N
73-4103 Extracorporal Inline Transonic Transit Time Flow Probe Type 1N
Login for U.S. Pricing
• Non-constrictive perivascular flowprobes
• For acute and chronic measurement of flow in arteries and veins
• large range of other vessel diameters from 500 æm to 36 mm
• Probes for micro-measurements in mice or rats
• Probes with Dual-beam "X"-Pattern for ascending aorta flow measurement
• Inline Flowprobes for extracorporal circuits (Isolated perfused organs)

In order to create an Inline Flowprobe for extracorporeal use, our engineers integrate the appropriate perivascular flowprobe into a block of clear Perspex using our proprietary process. The result is a robust flowprobe which can be spliced into standard laboratory tubing for virtually any application.Just as any flow probe we offer, the inline probes can be calibrated for use with blood, saline or buffer perfusates.

These Transonic Flow Probes work exclusively with the TTFM Transit Time Flow Meter (73-0146). The TTFM Flow Meter requires a PLUGSYS case (Type 601, 603 or 609).

Probes type R and S are available with back cable exit (in a right angle to the vessel) or with side cable exit (parallel to the vessel). Please note Cable Exit specification before ordering to ensure you receive the configuration you require. All are configured for acute use with the TTFM Transit Time Flow Meter and are calibrated for blood at 37°C.

A range of Accessories and special connectors for chronic applications are available, please call for information.

Specifications73-410573-410473-4103
Cable Exit
Cable Length Metric1.0m1.0m0.6m
Probe Length Metric61mm42mm25mm
Probe Type4N–HSE2N–HSE1N–HSE
Probe Width Metric4mm2mm1mm
Range Sc Low Metric100ml/min25ml/min2ml/min
Range Sc Maximum Metric600ml/min150ml/min30ml/min
Range Sc Normal Metric400ml/min100ml/min20ml/min
Resolution Metric0.4ml/min0.1ml/min0.05ml/min
SeriesN-SeriesN-SeriesN-Series
Vessel OD AcuteTube ID 4.8mmTube ID 3.2mmTube ID 1.2mm