CMA 20 Microdialysis Probes

CMA 20 Microdialysis Probes

The CMA 20 Microdialysis Probe is designed for dialysis experiments in moving soft tissues such as muscle, heart, skin and adipose tissue, as well as in blood, vitreous fluid of the eye, etc.

  • Tailored for dialysis in peripheral tissues and blood vessels
  • Inlet and outlet tubing is attached
  • Soft, non-metallic construction
  • Available membranes: PAES, 20 kDa MWCO or PES, 100 kDa MWCO
  • Membrane lengths - 4 or 10 mm

Item# Description U.S. List Price Quantity
CMA8010435 CMA 20 Elite Probe - 4mm (pkg. of 3)
CMA8010436 CMA 20 Elite Probe - 10mm (pkg. of 3)
CMA8309670 CMA 20 HighCO Probe - 4mm (pkg. of 3)
CMA8309671 CMA 20 HighCO Probe - 10mm (pkg. of 3)
Login for U.S. Pricing
The CMA 20 Microdialysis Probe is designed for dialysis experiments in moving soft tissues such as muscle, heart, skin and adipose tissue, as well as in blood, vitreous fluid of the eye, etc.

As with the other models, the probe is of concentric construction, but is made completely from plastic materials. Due to its flexibility, the probe must be implanted in the tissue with the help of a steel needle and a split tubing – the Introducer. The membrane is available in both 20 000 and 100 000 Daltons cut-off.

The CMA 20 Microdialysis Probes are guaranteed for single use, however, with proper care, they may be reused several times. Complete instructions are included in each package.

All CMA 20 packages are provided with 3 Introducers and 9 Split Tubing.
SpecificationsCMA8010435CMA8010436CMA8309670CMA8309671
Membrane Length4 mm10 mm4 mm10 mm
Membrane O D0.5 mm0.5 mm0.5 mm0.5 mm
Membrane MaterialPAESPAESPESPES
Molecular Weight Cut-off20 kDA MWCO20 kDA MWCO100 kDA MWCO100 kDA MWCO
Polyurethane Shaft Diameter0.77 mm0.77 mm0.77 mm0.77 mm
Probe Length (shaft+membrane) Metric24 mm24 mm24 mm24 mm
Intlet Internal Volume1.4 µL 1.4 µL 1.4 µL 1.4 µL
Outlet Internal Volume0.3 µL0.3 µL0.3 µL0.3 µL
membrane3.2 µL 2.6 µL 3.2 µL 2.6 µL
200 mm Inlet tubing (blue)3.6 µL3.6 µL3.6 µL3.6 µL
200 mm Outlet tubing (transp.)3.6 µL3.6 µL 3.6 µL 3.6 µL

Lindqvist A, Rip J, van Kregten J, Gaillard PJ, Hammarlund-Udenaes M. (2015 ) In vivo Functional Evaluation of Increased Brain Delivery of the Opioid Peptide DAMGO by Glutathione-PEGylated Liposomes. Pharm Res.

Brackin R, Näsholm T, Robinson N, Guillou S, Vinall K, Lakshmanan P, Schmidt S, Inselsbacher E. (2015 ) Nitrogen fluxes at the root-soil interface show a mismatch of nitrogen fertilizer supply and sugarcane root uptake capacity Sci Rep.

Abrahamsson P, Johansson G, Åberg AM, Winsö O, Blind PJ. (2015 ) Outcome of microdialysis sampling on liver surface and parenchyma J Surg Res.

DOCUMENT DESCRIPTION
CMA 12-20 Probes.pdfCMA 12 and CMA 20 Microdialysis Probes User's Manual
CMA 20 Elite Probe.pdfCMA 20 Elite Microdialysis Probe User's Manual