Cellulose Acetate Membranes with 10 to 200 µl Volumne

Cellulose Acetate Membranes with 10 to 200 µl  Volumne

These membranes are low protein binding and have a sharp MWCO range. The membranes are pre-cut, and supplied in 0.05% sodium azide solution. They are ready to use after rinsing with deionized water and buffer. Glycerol, sµlfur, and heavy metals are not present in these membranes. The Cellulose acetate membranes are intended only for aqueous solutions, and the presence of an organic solvent is not recommended.

Item# Description U.S. List Price Quantity
7424-CA300K Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 300,000 Dalton MWCO, Qty. of 25
7424-CA100K Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 100,000 Dalton MWCO, Qty. of 25
7424-CA50K Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 50,000 Dalton MWCO, Qty. of 25
7424-CA25K Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 25,000 Dalton MWCO, Qty. of 25
7424-CA10K Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 10,000 Dalton MWCO, Qty. of 25
7424-CA5K Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 5,000 Dalton MWCO, Qty. of 25
7424-CA2K Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 2,000 Dalton MWCO, Qty. of 25
7424-CA1K Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 1,000 Dalton MWCO, Qty. of 25
7424-CA500 Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 500 Dalton MWCO, Qty. of 25
7424-CA100 Membranes for Single-sided or Spin or Fast Flow Thru DIALYZERS size range 10 µl to 200 µl, Cellulose Acetate, 100 Dalton MWCO, Qty. of 25
Login for U.S. Pricing

These membranes are low protein binding and have a sharp MWCO range. The membranes are pre-cut, and supplied in 0.05% sodium azide solution. They are ready to use after rinsing with deionized water and buffer. Glycerol, sµlfur, and heavy metals are not present in these membranes. The Cellulose acetate membranes are intended only for aqueous solutions, and the presence of an organic solvent is not recommended.
Specifications7424-CA300K7424-CA100K7424-CA50K7424-CA25K7424-CA10K7424-CA5K7424-CA2K7424-CA1K7424-CA5007424-CA100
MWCO300,000100,00050,00025,00010,00050002,0001,000500100
MWCO UOMDaltonDaltonDaltonDaltonDaltonDaltonDaltonDaltonDaltonDalton
MaterialCellulose AcetateCellulose AcetateCellulose AcetateCellulose AcetateCellulose AcetateCellulose AcetateCellulose AcetateCellulose AcetateCellulose AcetateCellulose Acetate