Bronchospasmolysis channel 1

Bronchospasmolysis channel 1

Bronchospasmolysis channel 1

Item# Description U.S. List Price Quantity
73-2416 DOUBLE CHAMBER PLETHYSMOGRAPH BOX TYPE 855
73-1963 Aerosol Nebulizer
73-3300 Tubing Connection Kit for Aerosol Nebulizer
73-3882 DIFFERENTIAL LOW PRESSURE TRANSDUCER DLP2.5, RANGE +- 2.5 cmH2O, HSE CONNECTOR
73-0045 PLUGSYS Case, Type 603
73-0065 Transducer Amplifier Module (TAM-A)
73-1748 Plethysmograph Control Unit (PCU) for Channel 1
73-0585 DIAPHRAGM VALVE
Login for U.S. Pricing
Bronchospasmolysis channel 1
Specifications73-004573-006573-1748
AccessoriesLine Cable, Spare Fuses, Screw driver for fitting Function Modules, Document Folder for Operating Instructions of Function Modules, 3 x BNC-BNC Output linesTAM-A LED bar graph 20 LEDs (+13/-7) for visual check on the signal sensitivity approx. 1V/LED TAM-D 3 1/2-digit LED displayOperating Instructions
Connector5.2 x 19 x 17.1 inThrough 10-turn trimmer coarse adjustment and electronic autozero by push button (LED for error if autozero is not possible)DIN 41612, 96-pin VG
Dimensions (H x W x D) English132 x 483 x 435 mm+5V / 50 mA max.5.1 x 4.8 x 8.7 in
Dimensions (H x W x D) MetricMetallic housing, gray plastic coated, Universal 19 inch case with pivoting feet, prepared for rack mountingSelectable by switch on front panel:
a) 0 V output signal with switch in position '0'
b) Positive or negative calibration output voltage adjustable with 10-turn trimmer if switch is in position 'CAL'
128.7 x 121.9 x 220 mm
Inlet Compressed Air20 slot units max.Selectable ranges by internal Jumper: 0.2 to 10, 0.4 to 20, 1 to 50, 2 to 100, 4 to 200, 10 to 500, 20 to 1000, 100 to 5000, 200 to 10000. Fine Adjustment Through 10-Turn TrimmerFor switching membrane valves, driving aerosol jet nebulizer and generating bias flow in plethysmograph box via venturi jet — DO NOT exceed 6 bar
Inlet Oxygen100 to 240 VAC, 50/60 Hz, built-in line filter, 100 W max. consumptiona) Selectable by switch on front panel for pulsatile output signal: 1, 100, 300 Hz
b) Selectable by internal jumper for mean output signal: 0.1, 0.3 Hz
Receives oxygen for flushing plethysmograph box — DO NOT exceed 6 bar
LED Oxygen Fault3-pin IEC mains with fuse and mains switch on back of housing2 slot unitsBlinks and sounds beeper if no oxygen is delivered (empty cylinder or closed valve at oxygen pressure reducer)
PLUGSYS Width*14.3 lbs+5V through connector from PLUGSYS bus system6 slot units
Power Supply6.5 kga) On front panel through BNC socket 5 V/600 mA, through connector from PLUGSYS bus system
Weight (English)6-pin socket with screw lock (binder, Amphenol Tuchel) Differential input circuit, imput impedance 1010?1.8 lbs
Weight (Metric)0.8 kg